Photoelectric sensors FNDR 14G6903/S14 SmartReflect Light barriers dimension drawing 19,6 34,3 LED 4,5 4,2 15,4 * 17,7 11 4,5 29,8 51 61,8 REF 5,8 M12 x 1 10,2 20 10,9 * emitter axis photo general data type light barrier special type Washdown design version Foil detection light source pulsed point source LED background position Sde 200 ... 800 mm on V4A minimal signal attenuation 12 % alignment / soiled lens indicator flashing light indicator power on indication LED green output indicator LED red sensing distance adjustment Teach-in wave length 660 nm approvals/certificates Ecolab electrical data connection diagram response time / release time < 1,8 ms voltage supply range +Vs 10 ... 30 VDC current consumption max. (no load) 40 mA BN (1) current consumption typ. 35 mA WH (2) voltage drop Vd < 2 VDC output function light / dark operate output circuit push-pull output current < 100 mA short circuit protection yes reverse polarity protection yes Push Pull +VS Z BK (4) BU (3) Z Teach-in output 0V mechanical data width / diameter 19,6 mm height / length 51 mm depth 34,3 mm type rectangular housing material stainless steel 1.4404 (V4A) front (optics) PMMA connection types connector M12 FNDR 14G6903/S14 Sensor FDA compliant and Ecolab approved www.baumer.com sensitivity adjustable: via Teach-in wire input 24/4/2015 Photoelectric sensors FNDR 14G6903/S14 SmartReflect Light barriers ambient conditions operating temperature -30 ... +60 °C protection class IP 68/69K & proTect+ storage temperature -30 ... +70 °C FNDR 14G6903/S14 www.baumer.com 24/4/2015