FNDR 14G6903/S14

Photoelectric sensors
FNDR 14G6903/S14
SmartReflect Light barriers
dimension drawing
19,6
34,3
LED
4,5
4,2
15,4
* 17,7
11
4,5
29,8
51
61,8
REF
5,8
M12 x 1
10,2
20
10,9
* emitter axis
photo
general data
type
light barrier
special type
Washdown design
version
Foil detection
light source
pulsed point source LED
background position Sde
200 ... 800 mm on V4A
minimal signal attenuation
12 %
alignment / soiled lens indicator
flashing light indicator
power on indication
LED green
output indicator
LED red
sensing distance adjustment
Teach-in
wave length
660 nm
approvals/certificates
Ecolab
electrical data
connection diagram
response time / release time
< 1,8 ms
voltage supply range +Vs
10 ... 30 VDC
current consumption max. (no load)
40 mA
BN (1)
current consumption typ.
35 mA
WH (2)
voltage drop Vd
< 2 VDC
output function
light / dark operate
output circuit
push-pull
output current
< 100 mA
short circuit protection
yes
reverse polarity protection
yes
Push
Pull
+VS
Z
BK (4)
BU (3)
Z
Teach-in
output
0V
mechanical data
width / diameter
19,6 mm
height / length
51 mm
depth
34,3 mm
type
rectangular
housing material
stainless steel 1.4404 (V4A)
front (optics)
PMMA
connection types
connector M12
FNDR 14G6903/S14
Sensor FDA compliant and Ecolab
approved
www.baumer.com
sensitivity adjustable: via Teach-in wire
input
24/4/2015
Photoelectric sensors
FNDR 14G6903/S14
SmartReflect Light barriers
ambient conditions
operating temperature
-30 ... +60 °C
protection class
IP 68/69K & proTect+
storage temperature
-30 ... +70 °C
FNDR 14G6903/S14
www.baumer.com
24/4/2015