Reliability Report

AOS Semiconductor
Product Reliability Report
AOD442,
rev D
Plastic Encapsulated Device
ALPHA & OMEGA Semiconductor, Inc
www.aosmd.com
1
This AOS product reliability report summarizes the qualification result for AOD442. Accelerated
environmental tests are performed on a specific sample size, and then followed by electrical test
at end point. Review of final electrical test result confirms that AOD442 passes AOS quality and
reliability requirements. The released product will be categorized by the process family and be
routine monitored for continuously improving the product quality.
Table of Contents:
I.
II.
III.
IV.
Product Description
Package and Die information
Reliability Stress Test Summary and Results
Reliability Evaluation
I. Product Description:
The AOD442 used advanced trench technology to provide excellent RDS(ON) and low gate charge.
Those devices are suitable for use as a load switch or in PWM applications.
Details refer to the datasheet.
II. Die / Package Information:
Process
Package Type
Lead Frame
Die Attach
Bond
Mold Material
Moisture Level
AOD442
Standard sub-micron
60V N-Channel MOSFET
TO252
Bare Cu
Solder Paste
Al wire
Epoxy resin with silica filler
Up to Level 1
2
III. Reliability Stress Test Summary and Results
Test Item
Test Condition
Time Point
Total
Sample
Size
Number
of
Failures
Reference
Standard
HTGB
Temp = 150°C ,
Vgs=100% of Vgsmax
168 / 500 /
1000 hours
924 pcs
0
JESD22-A108
HTRB
Temp = 150°C ,
Vds=80% of Vdsmax
168 / 500 /
1000 hours
924 pcs
0
JESD22-A108
MSL
Precondition
168hr 85°C / 85%RH +
3 cycle reflow@260°C
(MSL 1)
-
5082 pcs
0
JESD22-A113
HAST
130°C , 85%RH,
33.3 psia,
Vds = 80% of Vdsmax
96 hours
924 pcs
0
JESD22-A110
H3TRB
85°C , 85%RH,
Vds = 80% of Vdsmax
1000 hours
924 pcs
0
JESD22-A101
Autoclave
121°C , 29.7psia,
RH=100%
96 hours
924 pcs
0
JESD22-A102
Temperature
Cycle
-65°C to 150°C ,
air to air,
250 / 500
cycles
924 pcs
0
JESD22-A104
HTSL
Temp = 150°C
1000 hrs
924 pcs
0
JESD22-A103
Power
15000
462 pcs
0
AEC Q101
Tj = 100°C
cycles
Cycling
Note: The reliability data presents total of available generic data up to the published date.
IV. Reliability Evaluation
FIT rate (per billion): 1.91
MTTF = 59839 years
The presentation of FIT rate for the individual product reliability is restricted by the actual burn-in
sample size. Failure Rate Determination is based on JEDEC Standard JESD 85. FIT means one
failure per billion hours.
2
9
Failure Rate = Chi x 10 / [2 (N) (H) (Af)] = 1.91
9
MTTF = 10 / FIT = 59839 years
Chi²= Chi Squared Distribution, determined by the number of failures and confidence interval
N = Total Number of units from burn-in tests
H = Duration of burn-in testing
Af = Acceleration Factor from Test to Use Conditions (Ea = 0.7eV and Tuse = 55°C)
Acceleration Factor [Af] = Exp [Ea / k (1/Tj u – 1/Tj s)]
Acceleration Factor ratio list:
55 deg C
70 deg C
85 deg C
100 deg C
115 deg C
Af
259
87
32
13
5.64
Tj s = Stressed junction temperature in degree (Kelvin), K = C+273.16
Tj u =The use junction temperature in degree (Kelvin), K = C+273.16
k = Boltzmann’s constant, 8.617164 X 10-5eV / K
130 deg C
150 deg C
2.59
1
3