AC-DC Converter DIP-Package ASD-10 Series, 10Watt FEATURES: Wide input voltage range Short circuit, over current protections Board in-line type installation High voltage isolation 4000Vac 100% burn-in test 3 year warranty Output voltage (Vdc) Output current (mA) Efficiency Typ. ASD10-3 3.3 2000 66% ASD10-5 5 2000 76% 9 1111 80% 12 830 81% ASD10-15 15 666 82% ASD10-24 24 420 83% Model ASD10-9 ASD10-12 Input voltage (Vac) 85-264 Note: other input and output models may available on request. ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin --- 85 -- 264 Vac Input frequency Fline --- 47 -- 440 Hz Full load, Vin =115Vac -- 210 -- mA Full load, Vin =230Vac -- 110 -- mA Cold start, Vin =1150Vac -- 16 -- A Cold start, Vin =230Vac -- 30 -- A Vin =230Vac/50Hz -- -- 0.1 mA Input current Inrush current Leakage current External Fuse www.pairuigroup.com Iin Iinrush Ileakage -- T1A/250Vac(Disconnected Slowly) Page: 1 / 4 Date: 11/09/2015 *Subject to change without notice AC-DC Converter DIP-Package ASD-10 Series, 10Watt ELECTRICAL Output Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Vout Vin=220-305Vac -- ±2 -- % Line regulation Vout-line Vin from 220Vac to 305Vac -- ±1 -- % Load regulation Vout-load 20%-100% load -- ±1 -- % Set-up rise time -- Full load, Vin =230Vac -- 110 -- ms Hold-up time -- Full load, Vin =230Vac -- 40 -- Vo =3.3V, 5V -- 50 -- mV Vo =9V, 12V, 15V, 24V -- 100 -- mV Output voltage accuracy Ripple ms Vripple Protection Over current It will auto-recovery after fault condition is removed Over voltage It will auto-recovery after fault condition is removed Short circuit Hiccup mode, it will auto-recovery after fault condition is removed Environment Storage Ambient operating temperature Operating relative humidity MTBF Tstorage Humidity: 10% RH to 95% RH Startup at rated voltage Ta (Please refer to derating curve) Ha Non condensing TMTBF Dimension(LxWxH) Full load, 230Vac input, 25℃ ambient temperature -40 -- +85 ℃ -40 -- +70 ℃ 10 -- 95 % 200 -- -- kHrs 50.8 x 25.4 x 15.3mm Safety Safety standards Design refer to UL1012, EN60950, UL60950 Withstand voltage I/P-O/P:4KVac Insulation Resistance I/P-O/P: EMI / RFI conducted EN55011, EN55022 (CISPR22) Class B www.pairuigroup.com >100M Ohms/500VDC/25℃/70%RH Page: 2 / 4 Date: 11/09/2015 *Subject to change without notice AC-DC Converter DIP-Package ASD-10 Series, 10Watt ELECTRICAL ℃ Notes: 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and input nominal voltage; 2. Ripple & Noise are measured at 20MHZ of bandwidth by using a 300mm twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. MECHANICAL CONNECTION PIN # SINGLE 1 AC(N) 2 AC(L) 3 +Vo 4 -Vo Note: Unit is mm(inch). ELECTRICAL CURVE DERATING CURVE www.pairuigroup.com STATIC CHARACTERISTIC CURVE Page: 3 / 4 Date: 11/09/2015 *Subject to change without notice AC-DC Converter DIP-Package ASD-10 Series, 10Watt NOTE BLOCK DIAGRAM RECOMMENDED TEST AND APPLICATION CIRCUIT Components 3.3V 5V 9V 12V 15V FUSE T1A/250V NTC 10D-9 NF Common Mode Choke, inductance=10mH, current=0.2-0.5A MOV 14D471K C1 X Capacitor, 104K/400V C2/C3 Y Capacitor, 102K/400V C4 470uF/16V 470uF/16V C5 D1 150uF/16V 120uF/16V 24V 120uF/25V 100uF/35V P6KE206A P6KE33A 104K/50V P6KE6.8A www.pairuigroup.com P6KE6.8A P6KE16A Page: 4 / 4 P6KE16A Date: 11/09/2015 *Subject to change without notice