ASD-10

AC-DC Converter
DIP-Package
ASD-10 Series, 10Watt
FEATURES:
Wide input voltage range
Short circuit, over current protections
Board in-line type installation
High voltage isolation 4000Vac
100% burn-in test
3 year warranty
Output voltage
(Vdc)
Output current
(mA)
Efficiency
Typ.
ASD10-3
3.3
2000
66%
ASD10-5
5
2000
76%
9
1111
80%
12
830
81%
ASD10-15
15
666
82%
ASD10-24
24
420
83%
Model
ASD10-9
ASD10-12
Input voltage
(Vac)
85-264
Note: other input and output models may available on request.
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
---
85
--
264
Vac
Input frequency
Fline
---
47
--
440
Hz
Full load, Vin =115Vac
--
210
--
mA
Full load, Vin =230Vac
--
110
--
mA
Cold start, Vin =1150Vac
--
16
--
A
Cold start, Vin =230Vac
--
30
--
A
Vin =230Vac/50Hz
--
--
0.1
mA
Input current
Inrush current
Leakage current
External Fuse
www.pairuigroup.com
Iin
Iinrush
Ileakage
--
T1A/250Vac(Disconnected Slowly)
Page: 1 / 4
Date: 11/09/2015
*Subject to change without notice
AC-DC Converter
DIP-Package
ASD-10 Series, 10Watt
ELECTRICAL
Output
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Vout
Vin=220-305Vac
--
±2
--
%
Line regulation
Vout-line
Vin from 220Vac to 305Vac
--
±1
--
%
Load regulation
Vout-load
20%-100% load
--
±1
--
%
Set-up rise time
--
Full load, Vin =230Vac
--
110
--
ms
Hold-up time
--
Full load, Vin =230Vac
--
40
--
Vo =3.3V, 5V
--
50
--
mV
Vo =9V, 12V, 15V, 24V
--
100
--
mV
Output voltage accuracy
Ripple
ms
Vripple
Protection
Over current
It will auto-recovery after fault condition is removed
Over voltage
It will auto-recovery after fault condition is removed
Short circuit
Hiccup mode, it will auto-recovery after fault condition is removed
Environment
Storage
Ambient operating
temperature
Operating relative
humidity
MTBF
Tstorage
Humidity: 10% RH to 95% RH
Startup at rated voltage
Ta
(Please refer to derating curve)
Ha
Non condensing
TMTBF
Dimension(LxWxH)
Full load, 230Vac input,
25℃ ambient temperature
-40
--
+85
℃
-40
--
+70
℃
10
--
95
%
200
--
--
kHrs
50.8 x 25.4 x 15.3mm
Safety
Safety standards
Design refer to UL1012, EN60950, UL60950
Withstand voltage
I/P-O/P:4KVac
Insulation Resistance
I/P-O/P:
EMI / RFI conducted
EN55011, EN55022 (CISPR22) Class B
www.pairuigroup.com
>100M Ohms/500VDC/25℃/70%RH
Page: 2 / 4
Date: 11/09/2015
*Subject to change without notice
AC-DC Converter
DIP-Package
ASD-10 Series, 10Watt
ELECTRICAL
℃
Notes: 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and
input nominal voltage;
2. Ripple & Noise are measured at 20MHZ of bandwidth by using a 300mm twisted pair-wire terminated with a
0.1μF & 47μF parallel capacitor.
MECHANICAL
CONNECTION
PIN #
SINGLE
1
AC(N)
2
AC(L)
3
+Vo
4
-Vo
Note:
Unit is mm(inch).
ELECTRICAL CURVE
DERATING CURVE
www.pairuigroup.com
STATIC CHARACTERISTIC CURVE
Page: 3 / 4
Date: 11/09/2015
*Subject to change without notice
AC-DC Converter
DIP-Package
ASD-10 Series, 10Watt
NOTE
BLOCK DIAGRAM
RECOMMENDED TEST AND APPLICATION CIRCUIT
Components
3.3V
5V
9V
12V
15V
FUSE
T1A/250V
NTC
10D-9
NF
Common Mode Choke, inductance=10mH, current=0.2-0.5A
MOV
14D471K
C1
X Capacitor, 104K/400V
C2/C3
Y Capacitor, 102K/400V
C4
470uF/16V
470uF/16V
C5
D1
150uF/16V
120uF/16V
24V
120uF/25V
100uF/35V
P6KE206A
P6KE33A
104K/50V
P6KE6.8A
www.pairuigroup.com
P6KE6.8A
P6KE16A
Page: 4 / 4
P6KE16A
Date: 11/09/2015
*Subject to change without notice