User's Manual Earth Ground Resistance Tester Kit Model 382252 Introduction Congratulations on your purchase of the Extech 382252 Earth Ground Resistance Tester Kit. This device can measure Earth Ground Resistance (in 3 ranges), Earth Voltage and Resistance (up to 200kand AC and DC voltage. This device was designed to meet EN61010-1 safety standards. Careful care and use of this meter will provide years of reliable service. Safety Please read the following safety information carefully before attempting to operate the meter and use the meter only as specified in this manual. Environmental safety information Do not use meter outdoors when precipitation is likely Installation Category III Pollution degree 2 Altitude: 2000 meters max. Ambient conditions: 32 to 104 F (0 to 40 C); RH: 80% max Observe the following international safety warning symbols o o Safety Symbols Caution: Refer to this manual before using this meter Dangerous Voltages Meter is protected throughout by double or reinforced insulation Organizations that provide rules and guidelines for proper grounding The National Electrical Code (NEC) Underwriters Laboratories (UL) National Fire Protection Association (NFPA) American National Standards Institute (ANSI) Occupational Safety Health Administration (OSHA) Telecommunications Industry Standard (TIA) 2 Model 382252-en-GB_V1.3 12/14 Meter Description 1. Digital Display – See Display Description below 2. HOLD key – Freezes measurement value on display 3. 0 ADJ control- Adjusts Zero value on display 4. Backlight key – Turns on Backlight 5. TEST key – Enables Earth Resistance and Earth Voltage Tests 2 6. Function Selector switch – Selects desired range and function 3 1 4 5 6 Top View 1. VC Input 2. P Input 3. COM/E Input 1 Display Description 1. Test status Icon 2. Battery Charge indicator - 3. Voltage Unit indicator 4. Audible Signal Icon 9 8 5. kUnits Indicators 7 6. Measurement Value 7. AC/DC Voltage Indicators 8. Low Battery Icon 9. HOLD Icon 1 2 3 2 3 4 5 6 3 Model 382252-en-GB_V1.3 12/14 Operation 0 Adjustment 1. Connect the test leads to the meter as follows: a. Green lead to the 'E' terminal b. Yellow lead to the 'P' terminal c. Red lead to the 'C' terminal 2. Set the function selector switch to the desired measurement range. 3. Short the 3 test leads together. 4. Press the TEST key. 5. Use the 0 Adjust knob to adjust the displayed reading to 0 6. Press to TEST key again to end the 0 adjustment process. Test Connection Diagram 1. 382252 Meter 2. Green Test Lead 3. Yellow Test Lead 4. Red Test Lead 5. Existing Ground 6. P1 Auxiliary Earth Bar 7. C1 Auxiliary Earth Bar 2 3 4 5 6 7 1 Test Preparation and Setup 1. Connect the test leads to the meter (1) as follows: Green lead (2) to the 'E' terminal Yellow lead (3) to the 'P' terminal Red lead (4) to the 'C' terminal 2. Drive the Auxiliary Earth Bars P1 (6) & C1 (7) into the ground. Align the bars equidistant to the existing Earth ground connection and in a straight line as shown in the diagram above. If the auxiliary bars are placed in close proximity to the ground stake, measurement inaccuracies will result. 3. Connect the clamp ends of the test leads to the Earth bars and existing ground connection as shown above: Green lead (2) to the existing ground (5) Yellow lead (3) to Earth Bar P1 (6) Red lead (4) to the Earth Bar C1 (7) 4 Model 382252-en-GB_V1.3 12/14 Earth Voltage Test 1. Set the function on the selector’s switch to the EARTH VOLATAGE position. 2. Confirm that the voltage measurement is less than 10V AC; otherwise accurate Earth resistance measurements cannot be made. If voltage is present (higher than 10V AC), the source of the voltage must be found and corrected before testing can continue. 3. Press to TEST key to end the test. Note the LCD reading. Earth Resistance Test 1. Set the meter's function switch to the desired resistance range. 2. Press the TEST button. . The “ “ icon will flash and the audible signal will sound. 3. Note the displayed reading. 4. If high resistance is detected, note the value and take appropriate steps to correct the ground connection if necessary. 5. Press to TEST key to end the test. 6. Readings of “1”… are typical when the test leads are not connected to the meter. HOLD Function The Hold function freezes the latest measurement reading on the LCD. 1. Press the HOLD key to freeze the reading on the LCD 2. Press the HOLD key again to exit the HOLD function. 3. The HOLD function does not retain measurement data if the meter is turned off. Backlight 1. Press the “ 2. The backlight will turn off after approximately 15 seconds. “ key to turn on the backlight. 200k Resistance Measurement 1. Connect the red test lead to the Vconnector and the black test lead to the COM connector. 2. Set the function selector switch to the 200kposition. 3. Connect the test probes to the circuit or component under test. 4. Note the displayed Resistance value. AC Voltage Measurement 1. Connect the red test lead to the Vconnector and the black test lead to the COM connector. 2. Set the function selector switch to the 750V AC position. 3. Connect the test probes to the circuit under test. 4. Note the displayed Voltage value. DC Voltage Measurement 1. Connect the red test lead to the Vconnector and the black test lead to the COM connector. 2. Set the function selector switch to the 1000V DC position. 3. Connect the test probes to the circuit under test. 4. Note the displayed Voltage value. 5 Model 382252-en-GB_V1.3 12/14 Maintenance Battery Replacement ' appears on the LCD, the meter's batteries must be changed. When the low battery icon ' 1. Remove power and disconnect the test leads from the meter. 2. Remove the tilt stand from the rear of the meter. 3. Remove the 4 battery compartment screws with a Phillips head screwdriver. 4. Remove the battery compartment cover and replace the six 1.5V 'AA' batteries. 5. Affix compartment cover and tighten screw. 6. Reattach the tilt stand. You, as the end user, are legally bound (Battery ordinance) to return all used batteries and accumulators; disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Cleaning and Storage Periodically wipe the meter's case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter is not to be used for a period longer than 60 days, remove the batteries and store them separately. Specifications General Specifications Measurements Earth Ground Resistance (in 3 ranges), Earth Voltage, AC Voltage to 750V and DC Voltage to 1000V Display Large LCD with dual display Sampling Time 2.5 times per second Test lead length Red lead: 50' (15m), Yellow: 33' (10m), Green: 16' (5m) Over-range indication '1' displayed as most significant digit Power supply Six 1.5V 'AA' batteries (included) Low battery indication LCD displays icon Auto Power Off After approximately 15minutes of use Safety EN-61010-1 category III Weight 700g (24.7oz) with batteries Dimensions 200 x 92 x 50 mm (7.9 x 3.62 x 2") Supplied accessories Multimeter Test leads (2), Earth Ground test leads (3), auxiliary earth bars (2), six 'AA' batteries, and carrying case Operating Conditions 0ºC to 40ºC (32ºF to 104ºF), with < 80% RH Storage Conditions -10ºC to 60ºC (14ºF to 140ºF), with < 70% RH 6 Model 382252-en-GB_V1.3 12/14 Measurement Specifications Measurement Earth Ground Resistance Earth Voltage Range Resolution Accuracy 20 0.01 ± (2% reading + 10 digits) 200 0.1 2000 1 0 to 200VAC Frequency: 40 to 500Hz 0 to 200kΩ Resistance ± (2% reading + 3 digits) 0.1V ± (3% reading +3digits) 0.1k ± (1% reading +2 digits) Overload Protection: 250 Vrms AC Voltage 0 to 750V 40 Hz to 400Hz Overload Protection: 750 Vrms, Input Impedance: 10M 0 to 1000V DC Voltage 1V ± (1.2% reading +10 digits) 1V ± (0.8% reading +3 digits) Overload Protection: 1000 Vrms, Input Impedance: 10M Copyright © 2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 7 Model 382252-en-GB_V1.3 12/14