PRQC Series

Corp. Automotive Components Gr.
PRQC Series
11st Dec. 2015
KYOCERA Corporation
Automotive Components
Engineering division
Engineering section
KYOCERA CONFIDENTIAL
TK-D2428-FE0044
1
1.Series Name
PRQC series
(+85deg.C / consumer/industrial / 3.2 x 1.3 mm)
2. Electrical Characteristics
(key parameters)
PN
PRQC8.00CR5010X000
PRQC10.00CR5010X000
PRQC12.00CR5010X000
PRQC16.00CR5010X000
PRQC20.00CR5010X000
PRQC8.00CR1010V00L
PRQC12.00CR1010V00L
PRQC16.00CR1010V00L
PRQC20.00CR1010V00L
Freq
Freq
Resonant
Freq
Initial
Temp
Impedance
Tolerance Stability
(MHz)
(%)
(%)
ohm
8.00
±0.5
±0.5
60
10.00
±0.5
±0.5
60
12.00
±0.5
±0.5
60
16.00
±0.5
±0.5
60
20.00
±0.5
±0.5
60
8.00
±0.1
±0.02
500
12.00
±0.1
±0.02
200
16.00
±0.1
±0.02
100
20.00
±0.1
±0.02
100
※
※
※
※ +70deg.C
KYOCERA CONFIDENTIAL
TK-D2428-FE0044
2
(other common parameters)
Items
Standard Test IC
Withstanding Voltage
Specifications
MC74HCU04
(Freescale)
100 V D.C. 10 sec max.
Max. Input Signal Voltage
Insulation Resistance
15 Vp-p
100 MΩ min. (at 10 V D.C.)
Operating Temperature Range
-40 to +85℃
Storage Temperature Range
-40 to +85℃
Aging for 10 years on Oscillating
Frequency
KYOCERA CONFIDENTIAL
fosc ±0.1 % max.
(at 25℃ from initial value)
TK-D2428-FE0044
3
3-1. Measurement Condition
4. Dimensions
The reference temperature shall be 25±2 ℃.
The measurement shall be performed in the temperature range
from 15 to 35℃ unless otherwise the result is doubtful.
3-2. Measurement Circuit
Oscillating frequency shall be measured using the Kyocera
standard test circuit shown in Fig. 1.
K800
Vdd=5.0V
14
MC74
MC74HCU
74HCU04
HCU04
(Freescale)
1 2 3 4
7
Out
Rf
Unit: mm
Resonator
Terminal: Ni/Sn plating
C1
C2
Rf=1MΩ
C1=C2= 10 pF (Reference)
Oscillating Frequency
e.g:800 show the oscillating frequency of 8.00 MHz.
Fig.1 Standard Measuring Circuits
Day Code
Date Code
2013
2014
2015
2016
Note:
KYOCERA CONFIDENTIAL
Jan.
Jan.
Jan.
Jan.
~
~
~
~
Dec.
Dec.
Dec.
Dec.
~
~
~
~
A M (except “ I ”)
N Z (except “O”)
a m (except “ i ”)
n z (except “o” )
The alphabet should be repeated after Jan.2017.
TK-D2428-FE0044
Day
Code
Day
Code
Day
Code
1
A
11
L
21
W
2
B
12
M
22
X
3
C
13
N
23
Y
4
D
14
P
24
Z
5
E
15
Q
25
a
6
F
16
R
26
b
7
G
17
S
27
c
8
H
18
T
28
d
9
J
19
U
29
e
10
K
20
V
30
f
31
g
4
5. Recommended Land Pattern
Unit: mm
6. Recommended IR Reflow Profile
300
Reflow
Temperature C
(º )
~
200
Preheat
150
KYOCERA CONFIDENTIAL
~
150 180 ºC
100
50
0.4
Peak: 260ºC
º Max
((Over 230º
230ºC, 30 to40sec)
40sec)
250
1.2
1 . 9 2 .1
1.2
90 to 120sec Over 200ºC
º
within 80sec
0
TK-D2428-FE0044
Time (Sec)
5