G-Series Datasheet [pdf]

G-Series
G-Series
TOGGLE SWITCHES
General purpose workhorses with options tailored to meet most any need. Ratings to 20A 277VAC,
international approvals, various actuator, bushing, termination, and circuit choices allow this toggle switch
to easily integrate into a variety of different applications. The G-Series is appropriate for usage in low
voltage DC applications.
Resources:
Download 3D CAD Files
IGS
Product Highlights:
Ratings to 20A 277VAC available
Metal bat or nylon bat/paddle actuator styles
ŠŠ UL, CSA and VDE approvals for select circuits
ŠŠ Suitable for low voltage 12/24V DC
STP
Typical Applications:
Marine
Food Service
ŠŠ Generator
ŠŠ Industrial Control
ŠŠ Office Automation
ŠŠ
ŠŠ
ŠŠ
ŠŠ
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: [email protected]
Application Support: [email protected]
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
2 | G-Series Toggle Switches - General Specifications, Ordering Scheme, Dimensional Specifications
Dielectric Strength
UL/CSA: 1000V - live to dead
metal parts & opposite polarity
Electrical Life
50,000 cycles - maintained
25,000 cycles - momentary
Mechanical Life
VDE: 4000V - live to dead metal
parts; 1250V - opposite polarity &
across open contacts
100,000 cycles
Operating Temperature
32°F to 185°F (0° to 85°C)
2GM51
73
1
Base Part Number
2
Actuator Style
1 BASE PART NUMBER: SERIES / CIRCUITRY / RATING / TERMINATION 3
Single Pole in Double Pole base Double Pole
10A 250VAC, 15A 125VAC, 3/4 HP 125-250VAC
solder lug .250 tab screw term. solder lug 2GA50 2GA51 2GA54 On-None-Off 2GK50 6GA5A 6GA5B 6GA5E (On)-None-Off 6GK5A 6GA5L 6GA5M 6GA5S On-None-(Off) 6GK5L 2GB50 2GB51 2GB54 On-None-On 2GL50 6GB5A 6GB5B 6GB5E On-None-(On) 6GL5A 2GC50 2GC51 2GC54 On-Off-On 2GM50 6GC5A 6GC5B 6GC5E On-Off-(On) 6GM5A 6GC5L 6GC5M 6GC5S (On)-Off-(On) 6GM5L 10A 250VAC, 15A 125VAC, 12 (6)A 250VAC T85/55 ENEC/VDE Approved 1
2GA90 2GA91 - On-None-Off
2GK90 2GB90 2GB91 -
On-None-On 2GL90 2GC90 2GC91 - On-Off-On
2GM90 Additional ratings up to 20A 125VAC, 12A 250VAC, 1HP 120-240 VAC
available. Consult factory for specifics.
2 ACTUATOR STYLE 4
unsealed BAT 73 PADDLE 5 NBL3 BAT 2
D-3B-B 2
PADDLE -
sealed 78 NBL8 -
D-4B-B .250 tab 2GK51 6GK5B 6GK5M 2GL51 6GL5B 2GM51 6GM5B 6GM5M screw term.
2GK54
6GK5E
6GK5S
2GL54
6GL5E
2GM54
6GM5E
6GM5S
2GK91
2GL91
2GM91
toggle length 0.687 0.687 0.687 0.687 bushing length
0.465
0.465
0.379
0.379
Notes:
1 Not available with 73 or NBL3 style toggles, T55 with 78 and NBL8 style toggles.
2 All nylon bushing and toggle.
3 Consult factory for .187 tab, wire lead and combination screw/tab/solder lug termination callouts.
4 Additional actuator options available. Consult factory.
5 Nylon toggle with black ebanol plated bushing.
( ) Indicates momentary function.
.687[17.44]
.075[1.91] DIA
.125[3.18] DIA
.055[1.40] DIA
15/32-32UNS-2A
THREAD
.330[8.38]
.187[4.74]
.465[11.81]
.437[11.09]
.394[10.00]
.250[6.35]
.187[4.74]
SOLDER LUG
.778[19.76]
.250 TAB (Q.C.)
.187 TAB (Q.C.)
TERMINAL TYPE
.422[10.72]
.778[19.76]
1.308[33.22]
.750[19.05]
KEYWAY
.072[1.82]
X
.038[.965] DP
#6-32NC-2
THREAD
.187[4.75]
6.000[152.40]
.141[3.58]
.370[9.39]
.187[4.75]
.500[12.70]
.286[7.26]
.350[8.89]
SCREW
(ASSEMBLED)
.490[22.86]
PRINTED
CIRCUIT
.376[9.55]
WIRE LEAD
.062[1.57]
.500[12.70] DIA
.500[12.70] DIA
.500[12.70] DIA
.750[19.05]
.075[1.905]
IEC APPROVED CONSTRUCTION
.038[9.65]
MOUNTING HOLE
WITH KEYWAY
.125[3.17] DIA
WITH LOCKING RING
*Manufacturer reserves the right to change product specification without prior notice.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Reps & Contact | 3
Authorized Sales Representatives
Click on the group name on the map below to find your local representative or visit
www.carlingtech.com/findarep.
«
«
Matera
W. Canada
Matera
E. Canada
MIDWEST
DM
Michigan
TEMCO Northwest
Alaska, Hawaii
«
NORTHERN
Hanna Lind Ltd.
Melody
Emery
Sierra
Bridge Marketing
Omega Limited
Dy-tronix Inc.
LD. Allen
Norris
DM Assoc
East
Pacent
DM
Assoc
TSI North
TSI
WEST
Signal
Enterprises
Luscombe
Engineering
Pinnacle Marketing
Matrix
DM Mexico
South America
Mexico
«
«
Sunbelt Components
SOUTHEAST
ProRep
Solutions
LATIN AMERICA
Americas
Europe
Middle East
Africa
Asia-Pacific
Oceania
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
Email: [email protected]
Northern Region Sales Office: [email protected]
Southeast Region Sales Office: [email protected]
Midwest Region Sales Office: [email protected]
West Region Sales Office: [email protected]
Latin America Sales Office: [email protected]
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
Email: [email protected]
Shenzhen, China: [email protected]
Shanghai, China: [email protected]
Pune, India: [email protected]
Kaohsiung, Taiwan: [email protected]
Yokohama, Japan: [email protected]
Europe | Middle East | Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
Email: [email protected]
Germany: [email protected]
France: [email protected]
www.carlingtech.com
REV_06_2016