From cell to inverter, we make solar shine FIT® heat-shrink tubing Bright Solutions Solar Power Wire and Cable materials. The FIT line consists of various tubing types, each designed with unique attributes that offer tubing solutions for the broadest possible range of applications and environments. FIT heat-shrink tubing seals and protects wire and cables from environmental and mechanical abuse—with a wide variety of shrink ratios and FIT-260, Irradiated Polyolefin, 2:1 Shrink Ratio, -55°C to +135°C • Approved for 600 V ground lead identification • Green with yellow stripe Part No. F rom residential rooftops to solar farms harvesting energy, Alpha Wire presents a product portfolio to help engineers and installers create reliable, durable solar systems. Our solar cables and photovoltaic wire are designed for the harsh environments of solar energy applications—the hot and cold of climate extremes, ozone and UV radiation, moisture, oil, and direct burial. Our specially formulated PVC jackets provide years of reliable service by withstanding the potential environments without failing or degrading. raid: A full range for power and control Regardless of your panelto-grid needs, we have the product to satisfy it. With wire and cable in a range of gauges and conductor counts, Alpha has the solar solution. Alpha also has the accessories, from flexible conduit to heatshrink tubing, to help you manage the system for faster installation, easier maintenance, and reliable operation. Our cables meet regulatory and industry requirements for photovoltaic application. This includes UL Subject 4703 Type PV. The cables you trust. The service you deserve. Every application is critical and wire failure is not an option when the reliability of your equipment and the safety of personnel are paramount. Specify Alpha cable for harsh solar power applications: the integrity of your system is only as robust as the products you use. right Alpha cable for your specific application. Our online resources include a wire and cable selection guide, technical information, full product catalog, and a distributor locator to make it easy to select and get the cable you need. Can’t find what you’re looking for? Design the cable to your specification. It’s easy, just visit www.alphawire.com! Applications Service and support, second-to-none Panel monitoring and control Selecting the correct cable for your critical application is essential to overall system reliability, performance, and safety. So we make it easy for you to select the Panel to collector Panel to junction box Min Supplied ID Max Recovered ID Nominal Recovered Wall Inch mm Inch mm Inch mm FIT-260-1/8 0.125 3.18 0.062 1.57 0.020 0.51 FIT-260-1/4 0.250 6.35 0.125 3.18 0.025 0.64 FIT-260-3/8 0.375 9.53 0.187 4.75 0.025 0.64 FIT-260-1/2 0.500 12.70 0.250 6.35 0.025 0.64 FIT-260-3/4 0.750 19.05 0.375 9.53 0.030 0.76 FIT-260-1 1.000 25.40 0.500 12.70 0.035 0.89 FIT-300, Semirigid Irradiated Polyolefin, 2.5:1 Shrink Ratio, -55°C to +125°C • Meltable inner wall to encapsulate without adhesive Part No. Min Supplied ID Inch Max Recovered ID mm Inch mm Nominal Recovered Wall Inch mm FIT-300-1/8 0.125 3.18 0.023 0.58 0.038 0.97 FIT-300-3/16 0.187 4.75 0.060 1.52 0.043 1.09 FIT-300-1/4 0.250 6.35 0.080 2.03 0.047 1.19 FIT-300-3/10 0.300 7.62 0.050 1.27 0.100 2.54 FIT-300-3/8 0.375 9.53 0.135 3.43 0.050 1.27 FIT-300-1/2 0.500 12.70 0.195 4.95 0.055 1.40 FIT-300-3/4 0.750 19.05 0.313 7.95 0.065 1.65 Collector to inverter FIT-750, Adhesive-Lined Polyolefin, 2:1 Shrink Ratio, -55°C to +110°C Grounding • Mastic lined • Bonds to most materials • High-voltage splicing: to 1 kV Motor supply Part No. Min Supplied ID Max Recovered ID Inch mm Inch Nominal Recovered Wall mm Inch mm FIT-750-1/4 0.250 6.35 0.125 3.18 0.030 0.76 FIT-750-3/8 0.375 9.53 0.187 4.75 0.031 0.79 FIT-750-1/2 0.500 12.70 0.250 6.35 0.032 0.81 FIT-750-3/4 0.750 19.05 0.375 9.53 0.037 0.94 FIT-750-1IN 1.000 25.40 0.500 12.70 0.039 0.99 FIT-750-1-1/2 1.500 38.10 0.750 19.05 0.046 1.17 GLOBAL HEADQUARTERS 711 Lidgerwood Avenue Elizabeth, NJ 07207-0711 USA Toll Free: 1-800-52 ALPHA Tel: 1-908-925-8000 Fax: 1-908-925-5411 E-mail: [email protected] EUROPE Alpha Wire International Saxon House 1 Downside | Sunbury-on-Thames Middlesex | United Kingdom | TW16 6RT Tel: +44-(0)-800-288-8809 Fax: +44-(0)-800-288-8810 E-mail: [email protected] ©2012 Alpha Wire. All rights reserved. Specifications subject to change. Consult Alpha Wire for latest specifications. ASIA PACIFIC Alpha Wire Silver Center | Room 1708 North Shanxi Road 1388 Shanghai | China | 200060 Tel: +86-21-61498201/61498205 Fax: +86-21-61498001 E-mail: [email protected] Cables you trust. Service you deserve. Lit. No. Solar-1207 Supersedes: Solar-1108 From cell to inverter, we make solar shine FIT® heat-shrink tubing Bright Solutions Solar Power Wire and Cable materials. The FIT line consists of various tubing types, each designed with unique attributes that offer tubing solutions for the broadest possible range of applications and environments. FIT heat-shrink tubing seals and protects wire and cables from environmental and mechanical abuse—with a wide variety of shrink ratios and FIT-260, Irradiated Polyolefin, 2:1 Shrink Ratio, -55°C to +135°C • Approved for 600 V ground lead identification • Green with yellow stripe Part No. F rom residential rooftops to solar farms harvesting energy, Alpha Wire presents a product portfolio to help engineers and installers create reliable, durable solar systems. Our solar cables and photovoltaic wire are designed for the harsh environments of solar energy applications—the hot and cold of climate extremes, ozone and UV radiation, moisture, oil, and direct burial. Our specially formulated PVC jackets provide years of reliable service by withstanding the potential environments without failing or degrading. raid: A full range for power and control Regardless of your panelto-grid needs, we have the product to satisfy it. With wire and cable in a range of gauges and conductor counts, Alpha has the solar solution. Alpha also has the accessories, from flexible conduit to heatshrink tubing, to help you manage the system for faster installation, easier maintenance, and reliable operation. Our cables meet regulatory and industry requirements for photovoltaic application. This includes UL Subject 4703 Type PV. The cables you trust. The service you deserve. Every application is critical and wire failure is not an option when the reliability of your equipment and the safety of personnel are paramount. Specify Alpha cable for harsh solar power applications: the integrity of your system is only as robust as the products you use. right Alpha cable for your specific application. Our online resources include a wire and cable selection guide, technical information, full product catalog, and a distributor locator to make it easy to select and get the cable you need. Can’t find what you’re looking for? Design the cable to your specification. It’s easy, just visit www.alphawire.com! Applications Service and support, second-to-none Panel monitoring and control Selecting the correct cable for your critical application is essential to overall system reliability, performance, and safety. So we make it easy for you to select the Panel to collector Panel to junction box Min Supplied ID Max Recovered ID Nominal Recovered Wall Inch mm Inch mm Inch mm FIT-260-1/8 0.125 3.18 0.062 1.57 0.020 0.51 FIT-260-1/4 0.250 6.35 0.125 3.18 0.025 0.64 FIT-260-3/8 0.375 9.53 0.187 4.75 0.025 0.64 FIT-260-1/2 0.500 12.70 0.250 6.35 0.025 0.64 FIT-260-3/4 0.750 19.05 0.375 9.53 0.030 0.76 FIT-260-1 1.000 25.40 0.500 12.70 0.035 0.89 FIT-300, Semirigid Irradiated Polyolefin, 2.5:1 Shrink Ratio, -55°C to +125°C • Meltable inner wall to encapsulate without adhesive Part No. Min Supplied ID Inch Max Recovered ID mm Inch mm Nominal Recovered Wall Inch mm FIT-300-1/8 0.125 3.18 0.023 0.58 0.038 0.97 FIT-300-3/16 0.187 4.75 0.060 1.52 0.043 1.09 FIT-300-1/4 0.250 6.35 0.080 2.03 0.047 1.19 FIT-300-3/10 0.300 7.62 0.050 1.27 0.100 2.54 FIT-300-3/8 0.375 9.53 0.135 3.43 0.050 1.27 FIT-300-1/2 0.500 12.70 0.195 4.95 0.055 1.40 FIT-300-3/4 0.750 19.05 0.313 7.95 0.065 1.65 Collector to inverter FIT-750, Adhesive-Lined Polyolefin, 2:1 Shrink Ratio, -55°C to +110°C Grounding • Mastic lined • Bonds to most materials • High-voltage splicing: to 1 kV Motor supply Part No. Min Supplied ID Max Recovered ID Inch mm Inch Nominal Recovered Wall mm Inch mm FIT-750-1/4 0.250 6.35 0.125 3.18 0.030 0.76 FIT-750-3/8 0.375 9.53 0.187 4.75 0.031 0.79 FIT-750-1/2 0.500 12.70 0.250 6.35 0.032 0.81 FIT-750-3/4 0.750 19.05 0.375 9.53 0.037 0.94 FIT-750-1IN 1.000 25.40 0.500 12.70 0.039 0.99 FIT-750-1-1/2 1.500 38.10 0.750 19.05 0.046 1.17 GLOBAL HEADQUARTERS 711 Lidgerwood Avenue Elizabeth, NJ 07207-0711 USA Toll Free: 1-800-52 ALPHA Tel: 1-908-925-8000 Fax: 1-908-925-5411 E-mail: [email protected] EUROPE Alpha Wire International Saxon House 1 Downside | Sunbury-on-Thames Middlesex | United Kingdom | TW16 6RT Tel: +44-(0)-800-288-8809 Fax: +44-(0)-800-288-8810 E-mail: [email protected] ©2012 Alpha Wire. All rights reserved. Specifications subject to change. Consult Alpha Wire for latest specifications. ASIA PACIFIC Alpha Wire Silver Center | Room 1708 North Shanxi Road 1388 Shanghai | China | 200060 Tel: +86-21-61498201/61498205 Fax: +86-21-61498001 E-mail: [email protected] Cables you trust. Service you deserve. Lit. No. Solar-1207 Supersedes: Solar-1108 Photovoltaic wire Solar cable for every solar application Our photovoltaic wire gives you flexible choices to meet UL 4703 PV wire and UL 4703 PV wire/TÜV 2 PFG 1169 wire requirements. Double insulated for maximum durability UL 4703 PV Wire UL 4703 PV Wire/TÜV 2 PFG 1169 Conductors Stranded tinned copper (30 AWG strands) Stranded tinned copper Insulation Material XL-PE LSZH Jacket Material PVC LSZH Bend Radius 10x 4x static/5x dynamic Flammability UL VW-1 IEC 60332-1 IEC 60754-1 and 60754-2 IEC 61034-2 UL VW-1 Voltage Rating UL: 2000 V Sunlight, ozone, and UV resistant Moisture resistant RoHS compliant REACH compliant -40°C to +90°C temperature range Features Part No. Wire Size UL 4703 PV Wire UL 4703 PV Wire/TÜV 2 PFG 1169 AWG mm2 PV1430 PVT1430 14 PV1230 PVT1228 PV1030 PV0830 Nominal Diameter UL 4703 PV Wire UL 4703 PV Wire/TÜV 2 PFG 1169 Inch mm Inch mm 2.54 0.267 6.78 0.228 5.79 12 4.51 0.286 7.26 0.248 6.30 PVT1028 10 6.77 0.311 7.90 0.268 6.81 PVT0826 8 10.00 0.390 9.91 0.357 9.07 PV0630 PVT0626 6 16.40 0.433 11.00 0.412 10.46 PV0430 PVT0426 4 25.50 0.491 12.47 0.463 11.76 PV0230 PVT0226 2 35.80 0.558 14.17 0.518 13.16 Series M and P control cables Series M and P cables set the performance standard for stationary cable tray applications with light to moderate flexing. They feature Size tough abrasion-resistant and sunlight-resistant jackets. Series M cables offer good resistance to oil and chemicals, while Series P cables’ thermoplastic elastomer jacket offers enhanced resistance and increased flexibility for easier routing. Series M Series P 18 – 8 AWG 18 – 8 AWG No. of Conductors 3 – 65 3 – 65 Insulation PVC/nylon PVC/nylon Our new multiconductor solar cable is the cable designed for any solar application. It is rated for direct burial. It handles extreme temperatures. It’s rated for temperatures as low as -40°C static and -30°C bending and as high as 90°C. And its tough, abrasionresistant jacket also resists Part No. UL: 600 V/TÜV: 1000 V Jacket Oil-resistant PVC Oil-resistant TPE Approvals UL Type TC-ER (600 V) UL Type MTW (600 V) UL Type PLTC (300 V) (18-12 AWG only) UL Type WTTC (1000 V) UL Type TC-ER (600 V) UL Type PLTC (300 V) (18-12 AWG only) CSA C(UL) CIC Control (600 V) CSA C(UL) TC (600 V) Features Direct burial Sunlight resistant Oil Res. I Sunlight resistant Oil Res. I/II Temperature Range -25°C to 90°C -25°C to 90°C sunlight, ozone, and UV radiation. Designed specifically for solar inverters and similar applications, it’s the perfect choice that goes wherever your solar farm is installed. • • • • • • TC-ER UL MTW VW-1 FT-1 1000 V Stranded bare copper conductors Size Conductors Shielded Unshielded AWG mm2 SPM1803CY SPM1803 18 0.96 SPM1804CY SPM1804 18 SPM1805CY SPM1805 18 • P VC jacket • P VC/nylon insulation • T inned copper braid shield, 85% coverage • S unlight, ozone, and UV resistant • D irect burial • O il Res. I • M oisture resistant • 1 0x bend radius • W ide temperature range: -40°C static/-30°C bending to +90°C We have a wide range of wire management accessories to make any installation easier to manage and maintain. Here are a few examples. Visit www.alphawire.com to learn more. Slit Loom Tubing Type 492 slit loom tubing Nominal Diameter Shielded Manage, ground, and protect Unshielded Inch mm Inch mm 3 0.329 8.36 0.301 7.65 0.96 4 0.354 8.99 0.326 8.28 0.96 5 0.381 9.68 0.353 8.97 SPM1807CY SPM1807 18 0.96 7 0.409 10.39 0.381 9.68 SPM1809CY SPM1809 18 0.96 9 0.466 11.84 0.438 11.13 SPM1603CY SPM1603 16 1.32 3 0.351 8.92 0.323 8.20 SPM1604CY SPM1604 16 1.32 4 0.378 9.60 0.350 8.89 SPM1605CY SPM1605 16 1.32 5 0.408 10.36 0.380 9.65 SPM1607CY SPM1607 16 1.32 7 0.439 11.15 0.411 10.44 SPM1609CY SPM1609 16 1.32 9 0.509 12.93 0.475 12.06 SPM1403CY SPM1403 14 2.08 3 0.381 9.68 0.353 8.97 SPM1404CY SPM1404 14 2.08 4 0.412 10.46 0.384 9.75 SPM1405CY SPM1405 14 2.08 5 0.446 11.33 0.418 10.62 • S implifies installation and protects cable • A vailable in inside diameters from 1/4 inch to 2 inches • F ull-length slit allows conduit to be slid over cable • E asy cable breakouts for routing flexibility • - 40°C to +93°C temperature range • Black polyethylene Liquid-Tight Flexible PVC Tubing Inside Diameter Part No. Inch mm Inch mm 492250 0.266 6.76 0.386 9.80 492350 0.360 9.14 0.511 12.98 492413 0.418 10.62 0.583 14.81 492500 0.495 12.57 0.682 17.32 492625 0.621 15.77 0.820 20.83 492750 0.733 18.62 0.970 24.64 492100 1.045 26.54 1.278 32.46 492150 1.607 40.82 1.907 48.44 492200 2.004 50.90 2.337 59.36 Liquid-tight flexible PVC tubing • W ater, oil, UV, and corrosion resistant • Withstands flexing and vibration • -18°C to +50°C • Companion connectors Outside Diameter Part No. PVC Tubing Size (In.) Nylon Connectors Straight Right Angle SLC1/4 — FNT3/8 SLC1/2 RLC3/8 1/2 FNT1/2 SLC3/8 RLC1/2 3/8 FNT1/4 1/4 SPM1407CY SPM1407 14 2.08 7 0.481 12.22 0.453 11.51 SPM1409CY SPM1409 14 2.08 9 0.590 14.99 0.556 14.12 SPM1203CY SPM1203 12 3.30 3 0.422 10.72 0.394 10.01 FNT3/4 SLC3/4 RLC3/4 3/4 FNT1 SLC1 RLC1 1 SPM1204CY SPM1204 12 3.30 4 0.458 11.63 0.430 10.92 SPM1205CY SPM1205 12 3.30 5 0.497 12.62 0.469 11.91 SPM1207CY SPM1207 12 3.30 7 0.574 14.58 0.510 12.95 SPM1209CY SPM1209 12 3.30 9 0.659 16.74 0.625 15.88 Solid bus bar wire • 12 to 6 AWG • T inned copper • M eets NEC 705.2 for panel grounding Part No. Wire Size Rating Specification AWG mm 12 0.081 A-A-59551 Type S 908 8 0.129 ASTM B 33, A-A-59551 Type S 906 6 0.162 ASTM B 33, A-A-59551 Type S 289 Photovoltaic wire Solar cable for every solar application Our photovoltaic wire gives you flexible choices to meet UL 4703 PV wire and UL 4703 PV wire/TÜV 2 PFG 1169 wire requirements. Double insulated for maximum durability UL 4703 PV Wire UL 4703 PV Wire/TÜV 2 PFG 1169 Conductors Stranded tinned copper (30 AWG strands) Stranded tinned copper Insulation Material XL-PE LSZH Jacket Material PVC LSZH Bend Radius 10x 4x static/5x dynamic Flammability UL VW-1 IEC 60332-1 IEC 60754-1 and 60754-2 IEC 61034-2 UL VW-1 Voltage Rating UL: 2000 V Sunlight, ozone, and UV resistant Moisture resistant RoHS compliant REACH compliant -40°C to +90°C temperature range Features Part No. Wire Size UL 4703 PV Wire UL 4703 PV Wire/TÜV 2 PFG 1169 AWG mm2 PV1430 PVT1430 14 PV1230 PVT1228 PV1030 PV0830 Nominal Diameter UL 4703 PV Wire UL 4703 PV Wire/TÜV 2 PFG 1169 Inch mm Inch mm 2.54 0.267 6.78 0.228 5.79 12 4.51 0.286 7.26 0.248 6.30 PVT1028 10 6.77 0.311 7.90 0.268 6.81 PVT0826 8 10.00 0.390 9.91 0.357 9.07 PV0630 PVT0626 6 16.40 0.433 11.00 0.412 10.46 PV0430 PVT0426 4 25.50 0.491 12.47 0.463 11.76 PV0230 PVT0226 2 35.80 0.558 14.17 0.518 13.16 Series M and P control cables Series M and P cables set the performance standard for stationary cable tray applications with light to moderate flexing. They feature Size tough abrasion-resistant and sunlight-resistant jackets. Series M cables offer good resistance to oil and chemicals, while Series P cables’ thermoplastic elastomer jacket offers enhanced resistance and increased flexibility for easier routing. Series M Series P 18 – 8 AWG 18 – 8 AWG No. of Conductors 3 – 65 3 – 65 Insulation PVC/nylon PVC/nylon Our new multiconductor solar cable is the cable designed for any solar application. It is rated for direct burial. It handles extreme temperatures. It’s rated for temperatures as low as -40°C static and -30°C bending and as high as 90°C. And its tough, abrasionresistant jacket also resists Part No. UL: 600 V/TÜV: 1000 V Jacket Oil-resistant PVC Oil-resistant TPE Approvals UL Type TC-ER (600 V) UL Type MTW (600 V) UL Type PLTC (300 V) (18-12 AWG only) UL Type WTTC (1000 V) UL Type TC-ER (600 V) UL Type PLTC (300 V) (18-12 AWG only) CSA C(UL) CIC Control (600 V) CSA C(UL) TC (600 V) Features Direct burial Sunlight resistant Oil Res. I Sunlight resistant Oil Res. I/II Temperature Range -25°C to 90°C -25°C to 90°C sunlight, ozone, and UV radiation. Designed specifically for solar inverters and similar applications, it’s the perfect choice that goes wherever your solar farm is installed. • • • • • • TC-ER UL MTW VW-1 FT-1 1000 V Stranded bare copper conductors Size Conductors Shielded Unshielded AWG mm2 SPM1803CY SPM1803 18 0.96 SPM1804CY SPM1804 18 SPM1805CY SPM1805 18 • P VC jacket • P VC/nylon insulation • T inned copper braid shield, 85% coverage • S unlight, ozone, and UV resistant • D irect burial • O il Res. I • M oisture resistant • 1 0x bend radius • W ide temperature range: -40°C static/-30°C bending to +90°C We have a wide range of wire management accessories to make any installation easier to manage and maintain. Here are a few examples. Visit www.alphawire.com to learn more. Slit Loom Tubing Type 492 slit loom tubing Nominal Diameter Shielded Manage, ground, and protect Unshielded Inch mm Inch mm 3 0.329 8.36 0.301 7.65 0.96 4 0.354 8.99 0.326 8.28 0.96 5 0.381 9.68 0.353 8.97 SPM1807CY SPM1807 18 0.96 7 0.409 10.39 0.381 9.68 SPM1809CY SPM1809 18 0.96 9 0.466 11.84 0.438 11.13 SPM1603CY SPM1603 16 1.32 3 0.351 8.92 0.323 8.20 SPM1604CY SPM1604 16 1.32 4 0.378 9.60 0.350 8.89 SPM1605CY SPM1605 16 1.32 5 0.408 10.36 0.380 9.65 SPM1607CY SPM1607 16 1.32 7 0.439 11.15 0.411 10.44 SPM1609CY SPM1609 16 1.32 9 0.509 12.93 0.475 12.06 SPM1403CY SPM1403 14 2.08 3 0.381 9.68 0.353 8.97 SPM1404CY SPM1404 14 2.08 4 0.412 10.46 0.384 9.75 SPM1405CY SPM1405 14 2.08 5 0.446 11.33 0.418 10.62 • S implifies installation and protects cable • A vailable in inside diameters from 1/4 inch to 2 inches • F ull-length slit allows conduit to be slid over cable • E asy cable breakouts for routing flexibility • - 40°C to +93°C temperature range • Black polyethylene Liquid-Tight Flexible PVC Tubing Inside Diameter Part No. Inch mm Inch mm 492250 0.266 6.76 0.386 9.80 492350 0.360 9.14 0.511 12.98 492413 0.418 10.62 0.583 14.81 492500 0.495 12.57 0.682 17.32 492625 0.621 15.77 0.820 20.83 492750 0.733 18.62 0.970 24.64 492100 1.045 26.54 1.278 32.46 492150 1.607 40.82 1.907 48.44 492200 2.004 50.90 2.337 59.36 Liquid-tight flexible PVC tubing • W ater, oil, UV, and corrosion resistant • Withstands flexing and vibration • -18°C to +50°C • Companion connectors Outside Diameter Part No. PVC Tubing Size (In.) Nylon Connectors Straight Right Angle SLC1/4 — FNT3/8 SLC1/2 RLC3/8 1/2 FNT1/2 SLC3/8 RLC1/2 3/8 FNT1/4 1/4 SPM1407CY SPM1407 14 2.08 7 0.481 12.22 0.453 11.51 SPM1409CY SPM1409 14 2.08 9 0.590 14.99 0.556 14.12 SPM1203CY SPM1203 12 3.30 3 0.422 10.72 0.394 10.01 FNT3/4 SLC3/4 RLC3/4 3/4 FNT1 SLC1 RLC1 1 SPM1204CY SPM1204 12 3.30 4 0.458 11.63 0.430 10.92 SPM1205CY SPM1205 12 3.30 5 0.497 12.62 0.469 11.91 SPM1207CY SPM1207 12 3.30 7 0.574 14.58 0.510 12.95 SPM1209CY SPM1209 12 3.30 9 0.659 16.74 0.625 15.88 Solid bus bar wire • 12 to 6 AWG • T inned copper • M eets NEC 705.2 for panel grounding Part No. Wire Size Rating Specification AWG mm 12 0.081 A-A-59551 Type S 908 8 0.129 ASTM B 33, A-A-59551 Type S 906 6 0.162 ASTM B 33, A-A-59551 Type S 289 Photovoltaic wire Solar cable for every solar application Our photovoltaic wire gives you flexible choices to meet UL 4703 PV wire and UL 4703 PV wire/TÜV 2 PFG 1169 wire requirements. Double insulated for maximum durability UL 4703 PV Wire UL 4703 PV Wire/TÜV 2 PFG 1169 Conductors Stranded tinned copper (30 AWG strands) Stranded tinned copper Insulation Material XL-PE LSZH Jacket Material PVC LSZH Bend Radius 10x 4x static/5x dynamic Flammability UL VW-1 IEC 60332-1 IEC 60754-1 and 60754-2 IEC 61034-2 UL VW-1 Voltage Rating UL: 2000 V Sunlight, ozone, and UV resistant Moisture resistant RoHS compliant REACH compliant -40°C to +90°C temperature range Features Part No. Wire Size UL 4703 PV Wire UL 4703 PV Wire/TÜV 2 PFG 1169 AWG mm2 PV1430 PVT1430 14 PV1230 PVT1228 PV1030 PV0830 Nominal Diameter UL 4703 PV Wire UL 4703 PV Wire/TÜV 2 PFG 1169 Inch mm Inch mm 2.54 0.267 6.78 0.228 5.79 12 4.51 0.286 7.26 0.248 6.30 PVT1028 10 6.77 0.311 7.90 0.268 6.81 PVT0826 8 10.00 0.390 9.91 0.357 9.07 PV0630 PVT0626 6 16.40 0.433 11.00 0.412 10.46 PV0430 PVT0426 4 25.50 0.491 12.47 0.463 11.76 PV0230 PVT0226 2 35.80 0.558 14.17 0.518 13.16 Series M and P control cables Series M and P cables set the performance standard for stationary cable tray applications with light to moderate flexing. They feature Size tough abrasion-resistant and sunlight-resistant jackets. Series M cables offer good resistance to oil and chemicals, while Series P cables’ thermoplastic elastomer jacket offers enhanced resistance and increased flexibility for easier routing. Series M Series P 18 – 8 AWG 18 – 8 AWG No. of Conductors 3 – 65 3 – 65 Insulation PVC/nylon PVC/nylon Our new multiconductor solar cable is the cable designed for any solar application. It is rated for direct burial. It handles extreme temperatures. It’s rated for temperatures as low as -40°C static and -30°C bending and as high as 90°C. And its tough, abrasionresistant jacket also resists Part No. UL: 600 V/TÜV: 1000 V Jacket Oil-resistant PVC Oil-resistant TPE Approvals UL Type TC-ER (600 V) UL Type MTW (600 V) UL Type PLTC (300 V) (18-12 AWG only) UL Type WTTC (1000 V) UL Type TC-ER (600 V) UL Type PLTC (300 V) (18-12 AWG only) CSA C(UL) CIC Control (600 V) CSA C(UL) TC (600 V) Features Direct burial Sunlight resistant Oil Res. I Sunlight resistant Oil Res. I/II Temperature Range -25°C to 90°C -25°C to 90°C sunlight, ozone, and UV radiation. Designed specifically for solar inverters and similar applications, it’s the perfect choice that goes wherever your solar farm is installed. • • • • • • TC-ER UL MTW VW-1 FT-1 1000 V Stranded bare copper conductors Size Conductors Shielded Unshielded AWG mm2 SPM1803CY SPM1803 18 0.96 SPM1804CY SPM1804 18 SPM1805CY SPM1805 18 • P VC jacket • P VC/nylon insulation • T inned copper braid shield, 85% coverage • S unlight, ozone, and UV resistant • D irect burial • O il Res. I • M oisture resistant • 1 0x bend radius • W ide temperature range: -40°C static/-30°C bending to +90°C We have a wide range of wire management accessories to make any installation easier to manage and maintain. Here are a few examples. Visit www.alphawire.com to learn more. Slit Loom Tubing Type 492 slit loom tubing Nominal Diameter Shielded Manage, ground, and protect Unshielded Inch mm Inch mm 3 0.329 8.36 0.301 7.65 0.96 4 0.354 8.99 0.326 8.28 0.96 5 0.381 9.68 0.353 8.97 SPM1807CY SPM1807 18 0.96 7 0.409 10.39 0.381 9.68 SPM1809CY SPM1809 18 0.96 9 0.466 11.84 0.438 11.13 SPM1603CY SPM1603 16 1.32 3 0.351 8.92 0.323 8.20 SPM1604CY SPM1604 16 1.32 4 0.378 9.60 0.350 8.89 SPM1605CY SPM1605 16 1.32 5 0.408 10.36 0.380 9.65 SPM1607CY SPM1607 16 1.32 7 0.439 11.15 0.411 10.44 SPM1609CY SPM1609 16 1.32 9 0.509 12.93 0.475 12.06 SPM1403CY SPM1403 14 2.08 3 0.381 9.68 0.353 8.97 SPM1404CY SPM1404 14 2.08 4 0.412 10.46 0.384 9.75 SPM1405CY SPM1405 14 2.08 5 0.446 11.33 0.418 10.62 • S implifies installation and protects cable • A vailable in inside diameters from 1/4 inch to 2 inches • F ull-length slit allows conduit to be slid over cable • E asy cable breakouts for routing flexibility • - 40°C to +93°C temperature range • Black polyethylene Liquid-Tight Flexible PVC Tubing Inside Diameter Part No. Inch mm Inch mm 492250 0.266 6.76 0.386 9.80 492350 0.360 9.14 0.511 12.98 492413 0.418 10.62 0.583 14.81 492500 0.495 12.57 0.682 17.32 492625 0.621 15.77 0.820 20.83 492750 0.733 18.62 0.970 24.64 492100 1.045 26.54 1.278 32.46 492150 1.607 40.82 1.907 48.44 492200 2.004 50.90 2.337 59.36 Liquid-tight flexible PVC tubing • W ater, oil, UV, and corrosion resistant • Withstands flexing and vibration • -18°C to +50°C • Companion connectors Outside Diameter Part No. PVC Tubing Size (In.) Nylon Connectors Straight Right Angle SLC1/4 — FNT3/8 SLC1/2 RLC3/8 1/2 FNT1/2 SLC3/8 RLC1/2 3/8 FNT1/4 1/4 SPM1407CY SPM1407 14 2.08 7 0.481 12.22 0.453 11.51 SPM1409CY SPM1409 14 2.08 9 0.590 14.99 0.556 14.12 SPM1203CY SPM1203 12 3.30 3 0.422 10.72 0.394 10.01 FNT3/4 SLC3/4 RLC3/4 3/4 FNT1 SLC1 RLC1 1 SPM1204CY SPM1204 12 3.30 4 0.458 11.63 0.430 10.92 SPM1205CY SPM1205 12 3.30 5 0.497 12.62 0.469 11.91 SPM1207CY SPM1207 12 3.30 7 0.574 14.58 0.510 12.95 SPM1209CY SPM1209 12 3.30 9 0.659 16.74 0.625 15.88 Solid bus bar wire • 12 to 6 AWG • T inned copper • M eets NEC 705.2 for panel grounding Part No. Wire Size Rating Specification AWG mm 12 0.081 A-A-59551 Type S 908 8 0.129 ASTM B 33, A-A-59551 Type S 906 6 0.162 ASTM B 33, A-A-59551 Type S 289 From cell to inverter, we make solar shine FIT® heat-shrink tubing Bright Solutions Solar Power Wire and Cable materials. The FIT line consists of various tubing types, each designed with unique attributes that offer tubing solutions for the broadest possible range of applications and environments. FIT heat-shrink tubing seals and protects wire and cables from environmental and mechanical abuse—with a wide variety of shrink ratios and FIT-260, Irradiated Polyolefin, 2:1 Shrink Ratio, -55°C to +135°C • Approved for 600 V ground lead identification • Green with yellow stripe Part No. F rom residential rooftops to solar farms harvesting energy, Alpha Wire presents a product portfolio to help engineers and installers create reliable, durable solar systems. Our solar cables and photovoltaic wire are designed for the harsh environments of solar energy applications—the hot and cold of climate extremes, ozone and UV radiation, moisture, oil, and direct burial. Our specially formulated PVC jackets provide years of reliable service by withstanding the potential environments without failing or degrading. raid: A full range for power and control Regardless of your panelto-grid needs, we have the product to satisfy it. With wire and cable in a range of gauges and conductor counts, Alpha has the solar solution. Alpha also has the accessories, from flexible conduit to heatshrink tubing, to help you manage the system for faster installation, easier maintenance, and reliable operation. Our cables meet regulatory and industry requirements for photovoltaic application. This includes UL Subject 4703 Type PV. The cables you trust. The service you deserve. Every application is critical and wire failure is not an option when the reliability of your equipment and the safety of personnel are paramount. Specify Alpha cable for harsh solar power applications: the integrity of your system is only as robust as the products you use. right Alpha cable for your specific application. Our online resources include a wire and cable selection guide, technical information, full product catalog, and a distributor locator to make it easy to select and get the cable you need. Can’t find what you’re looking for? Design the cable to your specification. It’s easy, just visit www.alphawire.com! Applications Service and support, second-to-none Panel monitoring and control Selecting the correct cable for your critical application is essential to overall system reliability, performance, and safety. So we make it easy for you to select the Panel to collector Panel to junction box Min Supplied ID Max Recovered ID Nominal Recovered Wall Inch mm Inch mm Inch mm FIT-260-1/8 0.125 3.18 0.062 1.57 0.020 0.51 FIT-260-1/4 0.250 6.35 0.125 3.18 0.025 0.64 FIT-260-3/8 0.375 9.53 0.187 4.75 0.025 0.64 FIT-260-1/2 0.500 12.70 0.250 6.35 0.025 0.64 FIT-260-3/4 0.750 19.05 0.375 9.53 0.030 0.76 FIT-260-1 1.000 25.40 0.500 12.70 0.035 0.89 FIT-300, Semirigid Irradiated Polyolefin, 2.5:1 Shrink Ratio, -55°C to +125°C • Meltable inner wall to encapsulate without adhesive Part No. Min Supplied ID Inch Max Recovered ID mm Inch mm Nominal Recovered Wall Inch mm FIT-300-1/8 0.125 3.18 0.023 0.58 0.038 0.97 FIT-300-3/16 0.187 4.75 0.060 1.52 0.043 1.09 FIT-300-1/4 0.250 6.35 0.080 2.03 0.047 1.19 FIT-300-3/10 0.300 7.62 0.050 1.27 0.100 2.54 FIT-300-3/8 0.375 9.53 0.135 3.43 0.050 1.27 FIT-300-1/2 0.500 12.70 0.195 4.95 0.055 1.40 FIT-300-3/4 0.750 19.05 0.313 7.95 0.065 1.65 Collector to inverter FIT-750, Adhesive-Lined Polyolefin, 2:1 Shrink Ratio, -55°C to +110°C Grounding • Mastic lined • Bonds to most materials • High-voltage splicing: to 1 kV Motor supply Part No. Min Supplied ID Max Recovered ID Inch mm Inch Nominal Recovered Wall mm Inch mm FIT-750-1/4 0.250 6.35 0.125 3.18 0.030 0.76 FIT-750-3/8 0.375 9.53 0.187 4.75 0.031 0.79 FIT-750-1/2 0.500 12.70 0.250 6.35 0.032 0.81 FIT-750-3/4 0.750 19.05 0.375 9.53 0.037 0.94 FIT-750-1IN 1.000 25.40 0.500 12.70 0.039 0.99 FIT-750-1-1/2 1.500 38.10 0.750 19.05 0.046 1.17 GLOBAL HEADQUARTERS 711 Lidgerwood Avenue Elizabeth, NJ 07207-0711 USA Toll Free: 1-800-52 ALPHA Tel: 1-908-925-8000 Fax: 1-908-925-5411 E-mail: [email protected] EUROPE Alpha Wire International Saxon House 1 Downside | Sunbury-on-Thames Middlesex | United Kingdom | TW16 6RT Tel: +44-(0)-800-288-8809 Fax: +44-(0)-800-288-8810 E-mail: [email protected] ©2012 Alpha Wire. All rights reserved. Specifications subject to change. Consult Alpha Wire for latest specifications. ASIA PACIFIC Alpha Wire Silver Center | Room 1708 North Shanxi Road 1388 Shanghai | China | 200060 Tel: +86-21-61498201/61498205 Fax: +86-21-61498001 E-mail: [email protected] Cables you trust. Service you deserve. Lit. No. Solar-1207 Supersedes: Solar-1108