UNISONIC TECHNOLOGIES CO., LTD M2125 LINEAR INTEGRATED CIRCUIT SINGLE-SUPPLY OPERTIONAL AMPLIFIER DESCRIPTION The UTC M2125 is a single-supply operational amplifier. FEATURES * Single-Supply Operation * Low Operating Voltage: ±2.7V~20V * Low Operating Current: 1.0mA (typ.) * Slew Rate: 1.2V/μs (typ.) ORDERING INFORMATION Ordering Number Note: M2125G-AF5-R M2125G-AL5-R Pin Assignment: I: VIN O: Output MARKING Package SOT-25 SOT-353 1 I+ I+ Pin Assignment 2 3 4 G IO G IO 5 V+ V+ Packing Tape Reel Tape Reel G: GND www.unisonic.com.tw Copyright © 2016 Unisonic Technologies Co., Ltd 1 of 5 QW-R105-025.H M2125 LINEAR INTEGRATED CIRCUIT PIN CONFIGURATION V+ 5 1 OUTPUT 4 2 3 +INPUT GND -INPUT EQUIVALENT CIRCUIT UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 2 of 5 QW-R105-025.H M2125 LINEAR INTEGRATED CIRCUIT ABSOLUTE MAXIMUM RATINGS (TA=25°C, unless otherwise specified) PARAMETER Supply Voltage Differential Input Voltage Input Voltage (Note 2) RATINGS UNIT +20 V +20 V -0.3 ~ +20 V SOT-25 200 mW Power Dissipation (TC=25°C) PD SOT-353 110 mW Junction Temperature TJ +125 °C Operating Temperature TOPR -40 ~ +85 °C Storage Temperature TSTG -60 ~ +150 °C Notes: 1. Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. 2. When the supply voltage is less than +20V, the absolute maximum input voltage is equal to the supply voltage. SYMBOL V+ VI(DIFF) VIN THARMAL DATA (TA=25°C, unless otherwise specified) PARAMETER junction to Ambient SYMBOL SOT-25 SOT-353 θJA RATING 230 350 UNIT °C/W °C/W ELECTRICAL CHARACTERISTICS (V+=5V, TA=25°C, unless otherwise specified) PARAMETER Input Offset Voltage Input Offset Current Input Bias Current Large Signal Voltage Gain Maximum Output Voltage Swings Input Common Mode Voltage Common Mode Rejection Ratio Supply Voltage Rejection Ratio Output Source Current Output Sink Current Operating Current Slew Rate Unity Gain Frequency SYMBOL VI(OFF) II(OFF) II(BIAS) GV VOM VI(CM) RR SVR ISOURCE ISINK ICC SR fT TEST CONDITIONS RL≥2kΩ RL=2kΩ + - VIN =1V, VIN =0V + VIN =0V, VIN =1V RL=∞ UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw MIN RS=0Ω 88 3.5 0 70 80 20 8 TYP 2 5 25 100 MAX 7 50 250 3.5 90 94 30 20 1.0 1.2 1.2 1.75 UNIT mV nA nA dB V V dB dB mA mA mA V/μs MHz 3 of 5 QW-R105-025.H M2125 LINEAR INTEGRATED CIRCUIT TYPICAL CHARSACTERISTICS V+=5V,TA=25°C 4 3 2 1 0 0.01 5 10 0.1 1 Output Source Current, ISOURCE(mA) 100 Maximum Output Voltag Swing vs. Load Resistance TA=25°C 3 V+=3V 2 1 100k UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw V+=5V,TA=25°C 4 3 2 1 0 0.01 10 0.1 1 Output Sink Current, ISINK (mA) 100 Operating Current vs.Temperature V+=5V 10k 100 1k Load Resistance, RL (Ω) 5 1.6 4 0 10 Maximum Output Voltage Swing, VOM(V) 5 Output Voltag vs. Output Sink Current Operating Current, ICC (mA) Maximum Output Voltage Swing, VOM(V) Maximum Output Voltage Swing, VOM(V) Maximum Output Voltag Swing vs. Output Source Current V+/V- =±2.5V 1.2 0.8 0.4 0 -50 0 25 50 75 -25 Ambient Tempurature, TA (°C) 100 4 of 5 QW-R105-025.H M2125 LINEAR INTEGRATED CIRCUIT TYPICAL CHARSACTERISTICS(Cont.) Input Offset Voltage vs.Tempurature Input Offset Current vs.Tempurature 3 V+=5V,RS=0Ω Input Offset Current, II(OFF) (nA) Input Offset Voltage, VI(OFF) (mV) 2 1 0 -1 -2 -50 0 75 25 50 -25 Ambient Tempurature, TA (°C) + V =5V 2 1 0 -1 -2 -50 100 -25 Maximum Output Voltage, SwingVOM(V) Input Bais Current, IB (nA) V+=5V 20 0 15 0 10 0 5 0 0 -50 0 75 25 50 -25 Ambient Tempurature, TA (°C) 25 50 75 100 Maximum Output Voltage Swing vs.Tempurature Input Bais Current vs. Tempurature 250 0 Ambient Tempurature, TA (°C) 100 5 V+=5V,RL=2kΩ 4 3 2 -50 0 25 50 75 -25 Ambient Tempurature, TA (°C) 100 UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 5 of 5 QW-R105-025.H