Issue Date: 2006-11-16 Amendment 1 2006-11-29 Page 1 of 2 Report Reference # E300305-A17-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Standards: Power Supplies for Information Technology Equipment Including Electrical Business Equipment QQGQ, QQGQ7 Listing Switching Power Supply JPW140********* or PW153********* (Where * may be alphanumeric.) Input Rating: 100-240 Vac, 50-60 Hz, 1.2 A Output Rating: 5.0 Vdc, 5.0 A or 9.0 Vdc, 4.0 A or 12.0 Vdc, 3.4 A or 15.0 Vdc, 2.7 A or 18.0 Vdc, 2.2 A or 24.0 Vdc, 1.7 A or 48.0 Vdc, 0.83 A UL 60950-1:2003, First Edition CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003 Applicant Name and Address: JEC KOREA CORP 26-6 WAU-RI BONGDAM-EUP HWASEONG-SHI KYUNGGI-DO 445-897 KOREA This Report includes the following parts, in addition to this cover page: 1. Specific Technical Criteria 2. Clause Verdicts 3. Critical Components 4. Enclosures Copyright © 2006 Issue Date: 2006-11-16 Amendment 1 2006-11-29 Page 2 of 2 Report Reference # E300305-A17-UL-1 This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Any information and documentation provided to you involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. Test Report By: Reviewed By: BONG-JAE SHIN Associate Project Engineer UL Korea, Ltd. HACK-SOO SONG Section Manager UL Korea, Ltd. Copyright © 2006