STR-X6759N Datasheet

STR-X6759N
Off-Line Quasi-Resonant Switching Regulators
Features and Benefits
▪ Quasi-resonant topology IC  Low EMI noise and soft
switching
▪ Bottom-skip mode  Improved system efficiency over
the entire output load by avoiding increase of switching
frequency
▪ Standby mode  Lowers input power at very light output
load condition
▪ Avalanche-guaranteed MOSFET  Improves system-level
reliability and does not require VDSS derating
▪ 650 VDSS / 0.385 Ω RDS(on)
▪ Various protections  Improved system-level reliability
▫ Pulse-by-pulse drain overcurrent limiting
▫ Overvoltage Protection (bias winding voltage sensing),
with latch
▫ Overload Protection with latch
▫ Maximum on-time limit
Package: 7-Pin TO-3P
Description
The STR-X6759N is a quasi-resonant topology IC designed for
SMPS applications. It shows lower EMI noise characteristics
than conventional PWM solutions, especially at greater than
2 MHz. It also provides a soft-switching mode to turn on the
internal MOSFET at close to zero voltage (VDS bottom point)
by use of the resonant characteristic of primary inductance
and a resonant capacitor.
The package is a fully molded TO-3P, which contains the
controller chip (MIC) and MOSFET, enabling output
power up to 280 W at 120 VAC input. The bottom-skip
mode skips the first bottom of VDS and turns on the MOSFET
at the second bottom point, to minimize an increase of
operating frequency at light output load, improving systemlevel efficiency over the entire load range.
A standby mode is executed by clamping the secondary output.
In general applications, standby mode reduces input power.
The soft-start mode minimizes surge voltage and reduces power
stress to the MOSFET and to the secondary rectifying diodes
during the start-up sequence.
Various protections such as overvoltage, overload, overcurrent,
maximum on-time protections and avalanche-energy guaranteed
MOSFET secure good system-level reliability.
Not to scale
Continued on the next page…
Typical Application
STRX6759N
SANKEN ELECTRIC CO., LTD.
http://www.sanken-ele.co.jp/en/
STR-X6759N
Off-Line Quasi-Resonant Switching Regulators
Description (continued)
Applications include the following:
▪ Set Top Box
▪ LCD PC monitor, LCD TV
▪ Printer, Scanner
▪ SMPS power supplies
Selection Guide
Part Number
Package
STR-X6759N
TO-3P
Absolute Maximum Ratings at TA = 25°C
Parameter
Drain Current1
Maximum Switching Current2
Single Pulse Avalanche Energy3
Input Voltage for Controller (MIC)
SS/OLP Terminal Voltage
FB Terminal Inflow Current
FB Terminal Voltage
OCP/BD Terminal Voltage
MOSFET Power Dissipation4
Symbol
IDpeak
IDmax
EAS
VCC
VSSOLP
IFB
VFB
VOCPBD
PD1
Conditions
Single pulse
TA = –20°C to 125°C
Single pulse, VDD = 30 V, L = 50 mH, ILpeak = 4.4 A
IFB within the limits of IFB
With infinite heatsink
Without heatsink
VCC × ICC
Recommended operation temperature, see cautions
Controller (MIC) Power Dissipation
PD2
Operating Internal Leadframe Temperature
TF
Operating Ambient Temperature
TOP
Storage Temperature
Tstg
Channel Temperature
Tch
1Refer to MOSFET ASO curve
2I
DMAX is the drain current determined by the drive voltage of the IC and the threshold voltage, Vth, of the MOSFET
3Refer to Avalanche Energy Derating curve
4Refer to MOSFET Ta-PD1 curve
Rating
22
22
500
35
–0.5 to 6.0
10
–0.5 to 9.0
–1.5 to 5.0
46
2.8
0.8
–20 to 125
–20 to 125
–40 to 125
150
Unit
A
A
mJ
V
V
mA
V
V
W
W
W
°C
°C
°C
°C
All performance characteristics given are typical values for circuit or
system baseline design only and are at the nominal operating voltage and
an ambient temperature, TA, of 25°C, unless otherwise stated.
STRX6759N
SANKEN ELECTRIC CO., LTD.
2
STR-X6759N
Off-Line Quasi-Resonant Switching Regulators
Functional
Block Diagram
Terminal List Table
Number
Name
1
D
Drain
MOSFET drain
2
S
Source
MOSFET source
3
GND
Ground terminal
Ground
4
VCC
Power supply terminal
Input of power supply for control circuit
5
SS/OLP
Soft Start/Overload Protection terminal
Input to set delay for Overload Protection and Soft Start operation
6
FB
Feedback terminal
Input for Constant Voltage Control and Burst (intermittent) Mode
oscillation control signals
7
OCP/BD
Overcurrent Protection/Bottom Detection
Input for Overcurrent Detection and Bottom Detection signals
STRX6759N
Description
Functions
SANKEN ELECTRIC CO., LTD.
3
STR-X6759N
Off-Line Quasi-Resonant Switching Regulators
STR-X6759N
A.S.O. temperature derating coefficient curve
STR-X6759N
MOS FET A.S.O. Curve
100
80
0.1ms
10
I D [A]
Drain Current
A.S.O. temperature derating coefficient (%)
100
Ta=25℃
Single pluse
60
40
1ms
Determ ined by O n-Reststacen
1
Apply A.S.O temperature coefficient
from the left graph to this curve for
evaluating actual operations' safety
20
0.1
0
0
20
40
60
80
100
1
120
10
100
1000
VDS[V]
Drain-to-Source Voltage
T F [℃]
Internal frame temperature
STR-X6759N
Avalanche energy derating curve
E AS temperature derating coefficient (%)
100
80
60
40
20
0
25
50
75
100
125
150
Tch[℃]
Channel temperature
STRX6759N
SANKEN ELECTRIC CO., LTD.
4
STR-X6759N
Off-Line Quasi-Resonant Switching Regulators
STR-X6759N
MOSFET Ta-PD1 Curve
STR-X6759N
MIC TF-PD2 C urve
60
1
50 PD1=46[W]
0.8
40
P D2 [W]
Power dissipation
PD1[W]
Power dissipation
With infinite heatsink
0.6
30
0.4
20
10
0.2
Without heatsink
PD1=2.8[W]
0
0
0
0 20 40 60 80 100 120 140 160
20
40
60
80 100 120 140
TF[℃]
Internal frame temperature
Ta [℃]
Ambient temperature
STR-X6759N
Transient thermal resistance curve
θch-c[℃/W]
Transient thermal resistance
1
0.1
0.01
0.001
1μ
100 m
t[sec]
Tim e
STRX6759N
SANKEN ELECTRIC CO., LTD.
5
STR-X6759N
Off-Line Quasi-Resonant Switching Regulators
ELECTRICAL CHARACTERISTICS
Characteristic
Symbol
Test Conditions
Min.
Typ.
Max.
Units
ELECTRICAL CHARACTERISTICS for Controller (MIC)1, valid at TA = 25°C, VCC = 20 V, unless otherwise specified
Power Supply Start-up Operation
Operation Start Voltage
VCC(ON)
VCC = 0→20 V
16.3
18.2
19.9
V
Operation Stop Voltage
VCC(OFF)
VCC = 20→8.8 V
8.8
9.7
10.6
V
Circuit Current In Operation
ICC(ON)
Circuit Current In Non-Operation
ICC(OFF)
Oscillation Frequency
VCC = 15 V
fosc
Soft Start Operation Stop Voltage
VSSOLP(SS) VSS/OLP increasing
Soft Start Operation Charging Current
ISSOLP(SS)
VSS/OLP = 0 V
–
–
6
mA
–
–
100
μA
19
22
25
kHz
1.1
1.2
1.4
V
–710
–550
–390
μA
Normal Operation
Bottom-Skip Operation Threshold Voltage 1
VOCPBD(BS1)
–0.720
–0.665
–0.605
V
Bottom-Skip Operation Threshold Voltage 2
VOCPBD(BS2)
–0.485
–0.435
–0.385
V
Overcurrent Detection Threshold Voltage
VOCPBD(LIM) VOCP/BD falling
–0.995
–0.940
–0.895
V
VOCP/BD = –0.95 V
–250
–100
–40
μA
Quasi-Resonant Operation Threshold Voltage 1
VOCPBD(TH1) VOCP/BD falling
0.28
0.40
0.52
V
Quasi-Resonant Operation Threshold Voltage 2
VOCPBD(TH2) VOCP/BD rising
OCP/BD Terminal Outflow Current
IOCPBD
0.67
0.80
0.93
V
VFB rising
1.32
1.45
1.58
V
IFB(ON)
VFB = 1.6 V
600
1000
1400
μA
Standby Operation Start Voltage
VCC(S)
VCC = 0→15 V, VFB = 1.6 V
10.3
11.2
12.1
V
Standby Operation Start Voltage Interval
VCC(SK)
VCC(SK) = VCC(S) – VCC(OFF)
1.10
1.35
1.65
V
Standby Non-Operation Circuit Current
ICC(S)
VCC = 10.2 V, VFB = 1.6 V
–
20
56
μA
FB Terminal Inflow Current, Standby Operation
IFB(S)
VCC = 10.2 V, VFB = 1.6 V
–
4
14
μA
FB Terminal Threshold Voltage, Standby Operation
VFB(S)
VCC = 15 V, VFB rising
0.55
1.10
1.50
V
Minimum On Time
tON(MIN)
0.65
1.05
1.45
μs
FB Terminal Threshold Voltage
VFB(OFF)
FB Terminal Inflow Current (Normal Operation)
Standby Operation
Protection Operation
Maximum On Time
tON(MAX)
27.5
32.5
39.0
μs
Overload Protection Operation Threshold Voltage
VSSOLP(OLP)
4.0
4.9
5.8
V
Overload Protection Operation Charging Current
ISSOLP(OLP) VSS/OLP = 2.5 V
–16
–11
–6
μA
VCC(OVP)
VCC = 0→30 V
25.5
27.7
29.9
V
ICC(H)
VCC(OFF) – 0.3 V
Overvoltage Protection Operation Voltage
Latch Circuit Holding
Current2
Latch Circuit Release Voltage2
VCC(La.OFF) VCC = 30→6 V, OVP operating
–
45
140
μA
6.0
7.2
8.5
V
–
V
μA
ELECTRICAL CHARACTERISTICS for MOSFET, valid at TA = 25°C, unless otherwise specified
Drain-to-Source Breakdown Voltage
Drain Leakage Current
VDSS
IDSS = 300 μA
650
–
IDSS
VDSSS = 650 V
–
–
300
IDS = 3.5 A
–
–
0.385
Ω
–
–
600
ns
–
–
0.99
°C/W
On Resistance
RDS(on)
Switching Time
tf
Thermal Resistance
Rθch-F
Channel to internal frame
1Current
polarity with respect to the IC: positive current indicates current sink at the terminal named, negative current indicates source at the
terminal named.
2The latch circuit means a circuit operated OVP and OLP.
STRX6759N
SANKEN ELECTRIC CO., LTD.
6
STR-X6759N
Off-Line Quasi-Resonant Switching Regulators
Package Outline Drawing, TO-3P
15.6 ±0.2
5.5±0.2
2 ±0.2
6
3.45±0.2
XXXXXXXX
6.7±0.5
3.35±0.1
+0.2
0.55 –0.1
5.8
REF
12.5±0.5
XXXXXXXX
3
XXXXXXXX
3.3
23 ±0.3
Branding
Area
Ø3.2 ±0.2
5.5±0.2
Gate Burr
View A
2X 2.54±0.1
4X 1.27±0.1
Terminal dimension at lead tip
4.3 ±0.5
3.6 ±0.5
Terminal dimension at lead tip
+0.2
1.33 –0.1
2
1
3
5
4
7
+0.2
5X 0.75 –0.1
+0.2
+0.2
5X 0.65 –0.1
2X 0.83 –0.1
6
+0.2
1.89 –0.1
Enlargement View A
0.5
0.5
Front View (Plan View)
Gate burr: 0.3 mm (max.)
Terminal core material: Cu
Terminal treatment: Ni plating and Pb-free solder dip
Leadform: 1905
Approximate weight: 6 g
Dimensions in millimeters
Drawing for reference only
Branding codes (exact appearance at manufacturer discretion):
1st line, type:
STR
2nd line, subtype: X6759
3rd line, lot:
YM DD N
Where: Y is the last digit of the year of manufacture
M is the month (1 to 9, O, N, D)
DD is the 2-digit date
N is the suffix of the subtype
Leadframe plating Pb-free. Device composition
includes high-temperature solder (Pb >85%),
which is exempted from the RoHS directive.
STRX6759N
SANKEN ELECTRIC CO., LTD.
7
STR-X6759N
Off-Line Quasi-Resonant Switching Regulators
Because reliability can be affected adversely by improper
storage environments and handling methods, please observe
the following cautions.
Cautions for Storage
• Ensure that storage conditions comply with the standard
temperature (5°C to 35°C) and the standard relative
humidity (around 40% to 75%); avoid storage locations
that experience extreme changes in temperature or
humidity.
• Avoid locations where dust or harmful gases are present
and avoid direct sunlight.
• Reinspect for rust on leads and solderability of the
products that have been stored for a long time.
Cautions for Testing and Handling
When tests are carried out during inspection testing and
other standard test periods, protect the products from
power surges from the testing device, shorts between
the product pins, and wrong connections. Ensure all test
parameters are within the ratings specified by Sanken for
the products.
Remarks About Using Silicone Grease with a Heatsink
• When silicone grease is used in mounting the products on
a heatsink, it shall be applied evenly and thinly. If more
silicone grease than required is applied, it may produce
excess stress.
• Volatile-type silicone greases may crack after long periods
of time, resulting in reduced heat radiation effect. Silicone
greases with low consistency (hard grease) may cause
cracks in the mold resin when screwing the products to a
heatsink.
Our recommended silicone greases for heat radiation
purposes, which will not cause any adverse effect on the
product life, are indicated below:
Type
Suppliers
G746
Shin-Etsu Chemical Co., Ltd.
YG6260
Momentive Performance Materials Inc.
SC102
Dow Corning Toray Co., Ltd.
Cautions for Mounting to a Heatsink
• When the flatness around the screw hole is insufficient, such
as when mounting the products to a heatsink that has an
extruded (burred) screw hole, the products can be damaged,
even with a lower than recommended screw torque. For
mounting the products, the mounting surface flatness should
be 0.05 mm or less.
•
Please select suitable screws for the product shape. Do not
use a flat-head machine screw because of the stress to the
products. Self-tapping screws are not recommended. When
using self-tapping screws, the screw may enter the hole
diagonally, not vertically, depending on the conditions of hole
before threading or the work situation. That may stress the
products and may cause failures.
• Recommended screw torque: 0.588 to 0.785 N●m (6 to 8
kgf●cm).
• For tightening screws, if a tightening tool (such as a driver)
hits the products, the package may crack, and internal
stress fractures may occur, which shorten the lifetime of
the electrical elements and can cause catastrophic failure.
Tightening with an air driver makes a substantial impact.
In addition, a screw torque higher than the set torque can
be applied and the package may be damaged. Therefore, an
electric driver is recommended.
When the package is tightened at two or more places, first
pre-tighten with a lower torque at all places, then tighten
with the specified torque. When using a power driver, torque
control is mandatory.
Soldering
• When soldering the products, please be sure to minimize
the working time, within the following limits:
260±5°C 10±1 s
(Flow, 2 times)
380±10°C 3.5±0.5 s (Soldering iron, 1 time)
• Soldering should be at a distance of at least 2.0 mm from
the body of the products.
Electrostatic Discharge
• When handling the products, the operator must be
grounded. Grounded wrist straps worn should have at
least 1 MΩ of resistance from the operator to ground to
prevent shock hazard, and it should be placed near the
operator.
• Workbenches where the products are handled should be
grounded and be provided with conductive table and floor
mats.
• When using measuring equipment such as a curve tracer,
the equipment should be grounded.
• When soldering the products, the head of soldering irons
or the solder bath must be grounded in order to prevent
leak voltages generated by them from being applied to the
products.
• The products should always be stored and transported in
Sanken shipping containers or conductive containers, or
be wrapped in aluminum foil.
Recommended operation temperature
• Inner frame temperature in operation TF = 115°C
STRX6759N
SANKEN ELECTRIC CO., LTD.
8
STR-X6759N
Off-Line Quasi-Resonant Switching Regulators
• The contents in this document are subject to changes, for improvement and other purposes, without notice. Make sure that this is the
latest revision of the document before use.
• Application and operation examples described in this document are quoted for the sole purpose of reference for the use of the products herein and Sanken can assume no responsibility for any infringement of industrial property rights, intellectual property rights or
any other rights of Sanken or any third party which may result from its use.
• Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure and defect of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at their own risk, preventative measures
including safety design of the equipment or systems against any possible injury, death, fires or damages to the society due to device
failure or malfunction.
• Sanken products listed in this document are designed and intended for the use as components in general purpose electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring equipment, etc.).
When considering the use of Sanken products in the applications where higher reliability is required (transportation equipment and
its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various safety devices, etc.), and whenever
long life expectancy is required even in general purpose electronic equipment or apparatus, please contact your nearest Sanken sales
representative to discuss, prior to the use of the products herein.
The use of Sanken products without the written consent of Sanken in the applications where extremely high reliability is required
(aerospace equipment, nuclear power control systems, life support systems, etc.) is strictly prohibited.
• In the case that you use Sanken products or design your products by using Sanken products, the reliability largely depends on the
degree of derating to be made to the rated values. Derating may be interpreted as a case that an operation range is set by derating the
load from each rated value or surge voltage or noise is considered for derating in order to assure or improve the reliability. In general,
derating factors include electric stresses such as electric voltage, electric current, electric power etc., environmental stresses such
as ambient temperature, humidity etc. and thermal stress caused due to self-heating of semiconductor products. For these stresses,
instantaneous values, maximum values and minimum values must be taken into consideration.
In addition, it should be noted that since power devices or IC's including power devices have large self-heating value, the degree of
derating of junction temperature affects the reliability significantly.
• When using the products specified herein by either (i) combining other products or materials therewith or (ii) physically, chemically
or otherwise processing or treating the products, please duly consider all possible risks that may result from all such uses in advance
and proceed therewith at your own responsibility.
• Anti radioactive ray design is not considered for the products listed herein.
• Sanken assumes no responsibility for any troubles, such as dropping products caused during transportation out of Sanken's distribution network.
• The contents in this document must not be transcribed or copied without Sanken's written consent.
STRX6759N
SANKEN ELECTRIC CO., LTD.
9