Datasheet

For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
date 11/2009
page 1 of 4
a division of CUI INC
SERIES:
DESCRIPTION:
12 W WALL PLUG
SWITCHING POWER SUPPLY
FEATURES
•universal AC input
•regulated output voltage
•short circuit, over load protection
•meets EISA / efficiency level IV regulations
•custom designs available
RoHS
MODEL
output voltage
output wattage
ripple*
nominal
(V dc)
output current
min
(A)
max
(A)
max
(W)
max.
(mVp-p)
efficiency level
cord length
EPS050250UPS-P5P-KH
5
0
2.5
12.5
80
IV
1800 ±30
EPS060175UPS-P5P-KH
6
0
1.75
10.5
80
IV
1800 ±30
(mm)
EPS090120UPS-P5P-KH
9
0
1.2
10.8
90
IV
1800 ±30
EPS120100UPS-P5P-KH
12
0
1.0
12
120
IV
1800 ±30
EPS150080UPS-P5P-KH
15
0
0.8
12
150
IV
1800 ±30
EPS180067UPS-P5P-KH
18
0
0.67
12.1
180
V
1800 ±30
EPS240050UPS-P5P-KH
24
0
0.5
12
240
IV
1800 ±30
*full load, 100~240 Vac input, measured at 20MHz bandwidth with a 22 uF electrolytic cap and a 0.1 uF ceramic cap on the output
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
fax 503.612.2382 www.v-infinity.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
date 11/2009
page 2 of 4
a division of CUI INC
SERIES:
12 W WALL PLUG
DESCRIPTION:
SWITCHING POWER SUPPLY
INPUT
parameter
max
units
rated input voltage
conditions/description
min
100
nom
240
V ac
input voltage range
90
264
V ac
rated frequency
50
60
Hz
frequency range
47
63
Hz
50
A
0.5
W
max
units
inrush current
no load power consumption
100 ~ 240 V ac input
OUTPUT
parameter
conditions/description
min
line regulation
nom
±2
load regulation
temp. coefficient
start-up time
at 110 V ac, full load
hold-up time
at 110 V ac, full load
%
±5
%
0.05
%/°C
2
10
over voltage protection
125%
overload protection
Overload results in decreased output voltage until
auto-recovery once the over load is removed.
short circuit protection
auto-recovery
s
ms
180%
V dc
max
units
3000
3000
V ac
V ac
SAFETY & EMI
parameter
conditions/description
HI-POT
input to output at 4 mA for 2 seconds
input to case at 4 mA for 2 seconds
min
insulation resistance
input to output at 500 V dc
safety approvals
UL/cUL (60950-1)
EMI standard
FCC part 15 class B
RoHS compliant
yes
LPS power supply
yes
nom
50
M
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
nom
0
max
units
40
°C
operating humidity
10
95
%
storage temperature
-20
70
°C
storage humidity
10
95
%
max
units
RELIABILITY
parameter
conditions/description
MTBF
at 25°C
20050 SW 112th Ave. Tualatin, Oregon 97062
min
nom
50,000
phone 503.612.2300
fax 503.612.2382 www.v-infinity.com
hours
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
date 11/2009
page 3 of 4
a division of CUI INC
SERIES:
DESCRIPTION:
12 W WALL PLUG
SWITCHING POWER SUPPLY
MECHANICAL DRAWING
refer to Cable
Gauge table
5.5
2.1
12
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
Cable Gauge
EPS050250
18 AWG
EPS060175
20 AWG
EPS090120
22 AWG
EPS120100
22 AWG
EPS150080
22 AWG
EPS180670
24 AWG
EPS240050
24 AWG
fax 503.612.2382 www.v-infinity.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
date 11/2009
page 4 of 4
a division of CUI INC
SERIES:
12 W WALL PLUG
DESCRIPTION:
SWITCHING POWER SUPPLY
INDIVIDUAL PACKAGING
PACKAGING
MODEL:
270
N.W.:
100V~120V
G.W.:
Q'TY: 100PCS
410
200V~240V
100V~120V
200V~240V
100V~240V
100V~240V
310
(Transverse Plane)
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
fax 503.612.2382 www.v-infinity.com