pdf

OPTOTRONIC® LED Power Supply
OT 100/120-277/800 2DIMLT2 P
Instruction Sheet
Technical Data
Nominal Input Voltage
Input Voltage (L/N)
Input Current
Mains Frequency
Power Factor
Control Input /Dimming
0-10V Interface
Standby Power
LED Interface
IP Rating
Remarks:
1)
220-240 Vac
120/277 Vac
108 – 305 Vac
1.06A @ 120 Vac
0,56A @ 230 Vac
50 / 60 Hz
≥ 0,95 @ 230 Vac
0-10V / 2DIM
< 1mA
No switch off possible
LEDset2 (LT2)
IP 64
277 Vac @ 60Hz:
220-240 Vac @ 50Hz:
120 Vac @ 60Hz:
Maximum Output Power Pmax
100W @ 537 - 800mA
Output Power Range
Maximum Output Voltage Uout
Rated Output Voltage
Rated Output Current
Rated Dimming Range
Ambient Temperature
Max. Case Temperature at tc
Max. Cable Length (LED+/LED-)
Max. Cable Length (LT2/NTCset)
Version
45 W – 100 W / 90W
200 Vdc
50 – 186 Vdc
350 – 800 mAdc
30 -100 %
1)
- 40°C to +55°C
+ 85°C
10 m
2m
AA68630
1)
Ta = -40°C to +50°C, Pmax= 100W
Ta = -40°C to +55°C, Pmax= 100W
Ta = -40°C to +45°C, Pmax= 90W
Read latest datasheet and the related documents (e.g application notes) before using the unit.
The documents are available on the internet (www.osram.com).
Operating Window
General Notes
•
•
•
•
•
•
•
•
•
The unit must be installed by a qualified electrician.
Do not service the unit when the mains voltage is connected.
Do not use damaged or defective contacts or housings.
Do not use damaged units.
The unit is intended for built-in use. The luminaire manufacturer is responsible to prevent direct exposure for
example to sunlight, water, snow, ice.
The luminaire manufacturer is responsible for its own luminaire design, this has to comply with all relevant safety
standards.
The maximum temperature should never exceed Tc(max) at the case temperature point (tc).
Cap off all unused wires to prevent accidental contact with other parts of the luminaire and driver.
Programmed parameters needs to be verified before usage (see restrictions: 0-10V/AstroDIM Features).
1
Edition:3rd August 2015
Ver.: 1.2
Status: Released
C10419714
G10549898
OPTOTRONIC® LED Power Supply
OT 100/120-277/800 2DIMLT2 P
Instruction Sheet
Default Parameter Settings
Dimming Mode
Output Current
Temperature Protection
Constant Lumen
Lamp Operating Time
End of Life
0-10V
0 -10 V
700 mA
Enabled; Resistor based; Start: 6,3 kOhm; End: 5,0 kOhm; Level 50%
OFF
0 khrs
OFF
Minimum Dimming Level 30 %
Programming
This unit is fully programmable via OSRAM OT Programmer with the help of the Tuner4TRONIC
Programming of the driver via Prog+ and Prog- is only allowed without powering it via L/N.
®
software.
The new programmed parameters would get valid with the next power on cycle. Further details are available in the
application guide for the 2DIMLT2 family.
Thermal Protection
This unit offers resistor based mode to set the thermal protection of the LED module or the luminaire. An external
temperature sensor (e.g. NTC) must be connected between LED- and NTCset. This feature is recommended to
guarantee long lifetime of the LED luminaire.
Resistor based
If the NTC value falls below the “start derating” resistance value, the unit starts derating down to set “derating level” at
the “end derating” value.
Start Derating
Temperature
[6,3 kOhm]
56 °C
66 °C
75 °C
85 °C
NTC Type
22K
33k
47k
68k
End Derating, Switch
On Temperature
[5,0 kOhm]
62 °C
72 °C
83 °C
92 °C
The temperature threshold would vary on the used NTC component and tolerance.
2
Edition:3rd August 2015
Ver.: 1.2
Status: Released
C10419714
G10549898
OPTOTRONIC® LED Power Supply
OT 100/120-277/800 2DIMLT2 P
Instruction Sheet
LEDset2 (LT2)
The unit offers two operating modes: “Fixed Current” or “LEDset2”. By default the “Fixed Current” Mode is enabled.
®
In case the LEDset2 interface is activated the external thermal protection feature is disabled. With the Tuner4TRONIC
it is feasible to set one of those two modes.
I OUT [A ] =
5V
×1000
Rset [Ω ]
Iout [mA]
Rset [kOhm]
Iout [mA]
Open Circuit
350
500
700
800
Undefined
Short Circuit
> 47,6
14.0 (E192)
10.0 (E192)
7,15 (E192)
6,19 (E192)
< 3,12
< 900
105
357
500
699
808
800/105
105
reference
nominal
Refer to the LEDset2 application note for further details.
0-10V/AstroDIM
®
Dimming down to 10% of the maximum rated output current could be enabled through the Tuner4TRONIC software,
but the compliance with EN61000-3-2 must be checked below 30% dimming level.
The device will follow the dimming scheme of each feature. When the output level in the dimming scheme is below the
minimum physical dimming level (minPHY), the minimum physical dimming level will be used.
Insulation
The unit has double/reinforced insulation from primary to the secondary side and double/reinforced insulation between
all electronic parts and the chassis.
Symbols:
The equipotential connection / casing (EQUI) meets the requirements for double insulation versus primary side.
Port
L/N
EQUI/
housing
0-10V
LT2
NTCset
Prog+
LED+
LEDProg-
L/N
-
double
basic
double
double
EQUI / housing
double
-
supplementary
basic
basic
0-10V
basic
supplementary
-
supplementary
supplementary
LT2/NTCset/Prog+
double
basic
supplementary
-
-
LED+/LED-/Prog-
double
basic
supplementary
-
-
‘-‘ no insulation
3
Edition:3rd August 2015
Ver.: 1.2
Status: Released
C10419714
G10549898
OPTOTRONIC® LED Power Supply
OT 100/120-277/800 2DIMLT2 P
Instruction Sheet
Wiring
•
•
•
•
•
•
•
•
•
The EQUI (=housing) [2] shall be connected to the heat sink of the LED module [1] to improve the surge
withstand capability of the system and EMI in critical luminaires.
The unit is suitable for protection class I and II luminaires. The connection of the EQUI (=housing) to protective
earth is only necessary in protection class I luminaires [3].
The connection of the EQUI (=housing) to Protective Earth is necessary to meet UL approbation in case of
connection to dead metal parts.
Maximum output cable length is limited by EMI and cross diameter.
This control gear is not suitable to disconnect the LED load during normal operation.
Input and Output Wire length: 280 mm +/- 20 mm
This control gear is inherently protected against wrong wiring on the output side. The wrong connections
between LED+ with LT2/NTCset could damage irreversibly the ECG. All the other wrong wirings on the output,
once removed, make the ECG work regularly.
The NTCset/LT2, LED+ and LED-, 0-10V cables are ESD protected up to 4kV according IEC 61000-4-2.
The startup time to reach the set output current is less than 5 s.
OSRAM GmbH
OSRAM China Lighting LTD.
Steinerne Furt 62,
86167 Augsburg, Germany
No. 1, North Industrial Road
528000 Foshan Guangdong, P.R. China
www.osram.com
www.osram.com
4
Edition:3rd August 2015
Ver.: 1.2
Status: Released
C10419714
G10549898