Datasheet

For more information, please visit the product page.
date
01/30/2013
page
1 of 5
SERIES: VBSD2-SIP │ DESCRIPTION: DC-DC CONVERTER
2 W isolated output
industry standard 7 pin SIP package
single unregulated outputs
1,000 V isolation
short circuit protection
wide temperature (-40~85°C)
efficiency up to 85%
U
•
•
•
•
•
•
•
ED
FEATURES
MODEL
input
voltage
output
voltage
range
(Vdc)
(Vdc)
VBSD2-S5-S5-SIP
5
4.5~5.5
VBSD2-S5-S9-SIP
5
VBSD2-S5-S12-SIP
5
output
current
output
power
ripple
and noise1
efficiency
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
5
40
400
2
150
81
4.5~5.5
9
23
222
2
150
84
4.5~5.5
12
17
167
2
150
83
TI
typ
(Vdc)
N
RoHS
5
4.5~5.5
15
14
133
2
150
84
VBSD2-S12-S5-SIP
12
10.8~13.2
5
40
400
2
150
81
VBSD2-S12-S9-SIP
12
10.8~13.2
9
23
222
2
150
82
VBSD2-S12-S12-SIP
12
10.8~13.2
12
17
167
2
150
85
VBSD2-S12-S15-SIP
12
10.8~13.2
15
14
133
2
150
82
VBSD2-S24-S5-SIP
24
21.6~26.4
5
40
400
2
150
80
24
21.6~26.4
9
23
222
2
150
83
24
21.6~26.4
12
17
167
2
150
84
24
21.6~26.4
15
14
133
2
150
84
24
21.6~26.4
24
10
84
2
150
84
VBSD2-S24-S12-SIP
VBSD2-S24-S15-SIP
IS
C
VBSD2-S24-S24-SIP
O
VBSD2-S24-S9-SIP
N
VBSD2-S5-S15-SIP
Notes:
1. ripple and noise are measured at 20 MHz BW
D
PART NUMBER KEY
Base Number
VBSD2 - SXX - SXX -SIP
Input Voltage
Output Voltage
cui.com
Packaging Style
For more information, please visit the product page.
CUI Inc │ SERIES: VBSD2-SIP │ DESCRIPTION: DC-DC CONVERTER
date 01/30/2013 │ page 2 of 5
INPUT
conditions/description
min
typ
max
units
operating input voltage
5 V model
12 V model
24 V model
4.5
10.8
21.6
5
12
24
5.5
13.2
26.4
Vdc
Vdc
Vdc
surge voltage
1 second max.
9
18
30
Vdc
Vdc
Vdc
0.4
A
max
units
1.2
%
15
15
15
15
%
%
%
%
5 V model
12 V model
24 V model
-0.7
-0.7
-0.7
reverse polarity input current1
input filter
1. if the product reverse did not seek to limit current, may result in injury or permanent damage, testing is not recommended
OUTPUT
conditions/description
line regulation
for Vin change of 1%
min
5 V model
9 V model
12 V model
15 V model
voltage accuracy
see derating curves
switching frequency
100% load, input voltage range
TI
load regulation
measured from 10%
load to full load
N
parameter
U
Notes:
C filter
ED
parameter
temperature coefficient
PROTECTIONS
parameter
conditions/description
N
short circuit protection
min
typ
12.8
8.3
6.8
6.3
75
kHz
±0.03
%/°C
typ
max
units
1
s
max
units
SAFETY AND COMPLIANCE
conditions/description
isolation voltage
for 1 minute at 1 mA max.
1,000
Vdc
at 500 Vdc
1,000
MΩ
3,500,000
hours
isolation resistance
safety approvals
MTBF
min
typ
UL
yes
IS
C
RoHS compliant
O
parameter
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
storage humidity
typ
max
units
-40
85
°C
-55
125
°C
95
%
non-condensing
at full load
1.5 mm from case for 10 seconds
25
D
temperature rise
lead temperature
cui.com
°C
300
°C
For more information, please visit the product page.
CUI Inc │ SERIES: VBSD2-SIP │ DESCRIPTION: DC-DC CONVERTER
date 01/30/2013 │ page 3 of 5
DERATING CURVES
2. output voltage vs. output current
ED
1. output power vs. ambient temperature
+10%
Output Voltate (%)
Load (%)
100
80
60
40
20
-20
0
20
40
60
85
105 120
-2.5%
-7.5%
50%
10%
MECHANICAL
parameter
conditions/description
dimensions
0.772 x 0.276 x 0.394 (19.60 x 7.00 x 10.00 mm)
case material
plastic (UL94-V0)
min
TI
weight
MECHANICAL DRAWING
N
units: mm [inches]
tolerance: ±0.25 [±0.010]
pin section tolerance: ±0.10 mm [±0.004]
>@
O
(Top View)
IS
C
>@
>@
>@
>@
(Bottom View)
>@
>@
>@
>@
cui.com
max
units
inch
2.8
PIN CONNECTIONS
>@
typ
>@
>@
>@
>@
(Front View)
>@
100%
Output Current (%)
N
Ambient Temperature (°C)
D
+2.5%
Voltage
U
-40
+5%
Nominal
PIN
FUNCTION
1
+Vin
2
GND
4
0V
5
No PIN
6
+Vo
g
∅0>@
For more information, please visit the product page.
CUI Inc │ SERIES: VBSD2-SIP │ DESCRIPTION: DC-DC CONVERTER
date 01/30/2013 │ page 4 of 5
APPLICATION NOTES
ED
1. Requirement on Output Load
In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the
minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may
increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an
appropriate resistor as extra loading.
2. Overload Protection
Under normal operating conditions, the output circuit of these products has no protection against over-current and short-circuits. The
simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit.
+Vo
Vin
DC DC
Cin
C out
0V
TI
GND
N
Figure 1
U
3. Filtering
In some circuits which are sensitive to noise and ripple, a filtering capacitor may be added to the DC/DC output end and input end to
reduce the noise and ripple. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a
startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest
capacitance of its filter capacitor sees the external capacitor table. To get an extremely low ripple, an “LC” filtering network may be
connected to the input and output ends of the DC/DC converter, which may produce a more significant filtering effect. It should also
be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid
mutual interference (Figure 1).
4. Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat
protection that is connected to the input or output end in series (Figure 2).
REG
N
Vin
Figure 2
GND
REG
+Vo
DC DC
0V
O
5. External Capacitor Table
It is not recommended to connect any external capacitor in the application field with less than 0.5 W output.
Vin
(Vdc)
Vout
(Vdc)
5
4.7
5
10
12
2.2
9
4.7
Cout
(µF)
24
1
12
2.2
--
--
15
1
--
--
24
1
D
IS
C
Table 1
Cin
(µF)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VBSD2-SIP │ DESCRIPTION: DC-DC CONVERTER
date 01/30/2013 │ page 5 of 5
REVISION HISTORY
description
date
08/30/2007
1.0
initial release
1.01
new template applied
1.02
V-Infinity branding removed
1.03
updated capacitor table
ED
rev.
04/17/2012
09/06/2012
01/30/2013
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.