Datasheet

For more information, please visit the product page.
date
09/07/2012
page
1 of 5
SERIES: VESD2-DIP │ DESCRIPTION: DC-DC CONVERTER
2 W isolated output
industry standard 14 pin DIP package
dual unregulated outputs
3,000 V isolation
short circuit protection
wide temperature (-40~85°C)
efficiency up to 87%
U
•
•
•
•
•
•
•
ED
FEATURES
input
voltage
MODEL
output
voltage
range
(Vdc)
(Vdc)
VESD2-S5-D5-DIP
5
4.5~5.5
VESD2-S5-D9-DIP
5
VESD2-S5-D12-DIP
5
output
current
output
power
ripple
and noise1
efficiency
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
±5
±20
±200
2
75
82
4.5~5.5
±9
±12
±111
2
75
83
4.5~5.5
±12
±9
±83
2
75
85
TI
typ
(Vdc)
N
RoHS
5
4.5~5.5
±15
±7
±67
2
75
85
12
10.8~13.2
±5
±20
±200
2
75
83
N
VESD2-S5-D15-DIP
VESD2-S12-D5-DIP
VESD2-S12-D9-DIP
12
10.8~13.2
±9
±12
±111
2
75
84
VESD2-S12-D12-DIP
12
10.8~13.2
±12
±9
±83
2
75
86
12
10.8~13.2
±15
±7
±67
2
75
86
24
21.6~26.4
±5
±20
±200
2
75
84
VESD2-S24-D9-DIP
VESD2-S24-D12-DIP
VESD2-S24-D15-DIP
24
21.6~26.4
±9
±12
±111
2
75
85
24
21.6~26.4
±12
±9
±83
2
75
87
24
21.6~26.4
±15
±7
±67
2
75
87
1. ripple and noise are measured at 20 MHz BW
IS
C
Notes:
O
VESD2-S12-D15-DIP
VESD2-S24-D5-DIP
D
PART NUMBER KEY
Base Number
VESD2 - SXX - DXX -DIP
Input Voltage
Output Voltage
cui.com
Packaging Style
For more information, please visit the product page.
CUI Inc │ SERIES: VESD2-DIP │ DESCRIPTION: DC-DC CONVERTER
date 09/07/2012 │ page 2 of 5
INPUT
conditions/description
min
typ
max
units
operating input voltage
5 V model
12 V model
24 V model
4.5
10.8
21.6
5
12
24
5.5
13.2
26.4
Vdc
Vdc
Vdc
parameter
conditions/description
min
typ
max
units
line regulation
for Vin change of 1%
1.2
%
load regulation
measured from 10% load to full load
15
%
OUTPUT
see derating curves
switching frequency
100% load, input voltage range
temperature coefficient
PROTECTIONS
conditions/description
min
N
parameter
10
short circuit protection
SAFETY AND COMPLIANCE
75
kHz
±0.03
%/°C
U
voltage accuracy
ED
parameter
units
1
s
max
units
isolation voltage
for 1 minute at 1 mA max.
3,000
Vdc
isolation resistance
at 500 Vdc
1,000
MΩ
safety approvals
UL
3,500,000
hours
ENVIRONMENTAL
operating temperature
storage temperature
storage humidity
at full load
typ
max
units
-40
85
°C
-55
125
°C
95
%
25
°C
300
°C
15
1.5 mm from case for 10 seconds
D
lead temperature
min
non-condensing
IS
C
temperature rise
conditions/description
O
parameter
N
yes
TI
conditions/description
RoHS compliant
typ
max
parameter
MTBF
min
typ
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VESD2-DIP │ DESCRIPTION: DC-DC CONVERTER
date 09/07/2012 │ page 3 of 5
DERATING CURVES
2. output voltage vs. output current
+10%
Output Voltate (%)
Load (%)
100
80
60
40
20
-20
0
20
40
60
85
105 120
Voltage
-2.5%
-7.5%
10%
50%
MECHANICAL
parameter
conditions/description
dimensions
0.803 x 0.323 x 0.394 (20.40 x 8.20 x 10.00 mm)
case material
plastic (UL94-V0)
min
typ
MECHANICAL DRAWING
N
O
Side View
max
2.1
g
Layout
IS
C
20.40
8.20
14
9 8
1
7
4.10
Bottom View
10.00 7.62
1
14
PIN CONNECTIONS
7
10 9 8
15.24
cui.com
units
inch
TI
weight
units: mm
tolerance: ±0.25mm
pin section tolerance: ±0.10mm
100%
Output Current (%)
N
Ambient Temperature (°C)
D
+2.5%
U
-40
+5%
Nominal
ED
1. output power vs. ambient temperature
PIN
FUNCTION
1
-Vin
7
NC
8
+Vo
9
COM
10
-Vo
14
+Vin
For more information, please visit the product page.
CUI Inc │ SERIES: VESD2-DIP │ DESCRIPTION: DC-DC CONVERTER
date 09/07/2012 │ page 4 of 5
APPLICATION NOTES
Input filtering
To reduce the reflected ripple current and minimize EMI, especially when the converter input is more than 2” away from the DC
source, it is recommended to connect a low ESR electrolytic capacitor between Vin and Gnd. The values suggested are as shown in
Table 1. If additional filtering is required, the capacitance may be increased, or expanded to an LC network as shown in Figure 1.
Table 1
Input Voltage
External Input
Capacitance
5V
4.7 μF
12 V
2.2 μF
24 V
1.0 μF
ED
1.
L
L
+Vin
C
-Vin
DC DC
C
L
C
+Vout
COM
-Vout
Output Voltage
5V
Table 2
9V
12 V
4.7 μF
+Vin
-Vin
+Vout
REG
REG
DC
DC DC
DC
-Vout
2.2 μF
1.0 μF
+Vin
0.47 μF
-Vin
COM
REG
REG
+Vout
REG
REG
-Vout
DC
DC DC
DC
COM
Figure 2
N
15 V
External Input
Capacitance
N
Output filtering
An output capacitor is needed to meet output ripple requirements as shown in Table 2. Output capacitance may be increased for additional filtering, but should not exeed 10μF or expanded to an LC network as in Figure 1.
TI
2.
U
Figure 1
Minimum loading
The converter needs a minimum of 10% loading to maintain output regulation. Operation under no-load conditions will not cause immediate damages but may reduce reliability, and cause performance not to meet specifications.
4.
Regulation
With a semi-regulated design, the converter’s output voltage varies with load current and will change proportionally to the input voltage. If regulated output is needed, an external regulator can be used as shown in Figure 2.
5.
Protection
The converter has minimal protection against input over-voltage or output over-load, and may be permanently damaged if exposed to
these conditions. An input clamping device can be used for input voltage limiting. An input fuse or an output fuse can also be used to
protect against over-loading.
IS
C
O
3.
Dual outputs used as a single output
The +Vout and -Vout can be used to obtain a single output that is the sum of the two outputs. In this case, the COM pin shouldn’t be
used.
7.
External Regulator
An external 3-terminal regulator can be connected to the output of the converter to achieve full regulation. Make sure the converter’s
output voltage provides sufficient head room for the regulator. An additional benefit is that the built-in protection features in the regulator, such as OCP, OTP, etc, will protect the converter also. In a complimentory supply, a negative output regulator must be used to
achieve the negative regulated output.
D
6.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VESD2-DIP │ DESCRIPTION: DC-DC CONVERTER
date 09/07/2012 │ page 5 of 5
REVISION HISTORY
description
date
1.0
initial release
06/20/2006
1.01
new template applied, V-Infinity branding removed
ED
rev.
09/07/2012
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.