NA5814-AL

Document 1042
Flyback Transformer
For Microchip AN1444
Microinverter
• Developed for the Microchip AN1444 Grid-Connected Solar
Microinverter
• Designed to operate at 57 kHz with 20 – 55 Vdc input
• Rectified sine wave output
• Maximum power: 100 W
• 3000 Vrms, one minute isolation primary to secondary
• 1500 Vrms, one minute isolation windings to core
Core material Ferrite
Terminations RoHS tin-silver-copper over tin over copper-clad steel.
Weight 90 g
Ambient temperature –40°C to +85°C
Storage temperature Component: –40°C to +85°C.
Tray packaging: –40°C to +80°C
Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C /
85% relative humidity)
Failures in Time (FIT) / Mean Time Between Failures (MTBF)
38 per billion hours / 26,315,789 hours, calculated per Telcordia SR-332
Packaging 20 parts per tray
PCB washing Tested with pure water or alcohol only. For other solvents,
see Doc787_PCB_Washing.pdf
Part
number
NA5814-AL
NA5919-AL
at 0 A1 L at Ipk2
±10% (µH) min (µH)
55.0
44.0
55.0
38.5
L
DCR max (Ohms)3
pri sec
0.0475
0.360
0.0480
0.110
Leakage
L4
max (µH)
1.45
1.58
Turns
ratio
pri : sec
1 : 7
1 : 4
Ipk2 Output
(A)(Vrms)
13.6
230
13.6
110
1. Inductance is for the primary, measured at 150 kHz, 1.0 Vrms, 0 Adc.
2.Ipk is the peak current drawn at minimum input voltage.
3. DCR for the primary is with windings connected in parallel
4. Leakage inductance measured on the primary winding with the secondary pins shorted.
5. Ambient operating temperature range –40°C to +85°C.
6. Electrical specifications at 25°C.
Dot indicates pin 1
1
0.047 ∅(12)
1,20
0.200 (8)
5,08
12
NA5814-AL
XXXX Y
6
1.670 max
42,40
7
1.968 max
50,0
1.400
35,56
0.300 (2)
7,62
5
6
10
Pri
Sec
2
1
12
Primary windings to be connected
in parallel on the PC board.
Recommended
Board Layout
1.200 max
30,48
0.031 (12)
0,80
0.130 min
3,30
Dimensions are in
inches
mm
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
Document 1042 Revised 04/23/14
© Coilcraft Inc. 2014
This product may not be used in medical or high
risk applications without prior Coilcraft approval.