Document 1103-1 Current Sense Transformers – SCS Series • Sensed current up to 30 A • Frequency range up to 1 MHz • 500 Vrms, one minute isolation (hipot) between windings. Core material Ferrite Terminations RoHS compliant matte tin over nickel over phos bronze Weight 3.4 – 3.7 g Ambient temperature –40°C to +125°C Storage temperature Component: –40°C to +125°C. Tape and reel packaging: –40°C to +80°C Resistance to soldering heat Max three 40 second reflows at +260°C, parts cooled to room temperature between cycles Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C / 85% relative humidity) Failures in Time (FIT) / Mean Time Between Failures (MTBF) 38 per billion hours / 26,315,789 hours, calculated per Telcordia SR-332 Packaging 200/13″ reel Plastic tape: 32 mm wide, 0.5 mm thick, 24 mm pocket spacing, 3.0 mm pocket depth PCB washing Tested with pure water or alcohol only. For other solvents, see Doc787_PCB_Washing.pdf 6 DCR max Frequency Volt-time SensedTerminating (Ohms) 2 current I 5 resistance R 6 Turns (N) Inductance range product4 in T Part number1 pri : sec min (mH) pri sec (kHz) (Vµsec) max (A) (Ohms) SCS-050L_1 : 50 3.8 0.0024 0.90 6 – 1000 80 30 1.7 SCS-100L_1 : 100 14.8 0.0024 1.80 3 – 1000 160 30 3.3 SCS-200L_1 : 200 59.2 0.0024 3.90 2 – 1000 320 30 6.7 1. When ordering, please specify packaging code: SCS-200LD Packaging:D =13″ machine-ready reel. EIA-481 embossed plastic tape (200 parts per full reel). B=Less than full reel. In tape, but not machine ready. To have a leader and trailer added ($25 charge), use code letter C instead. 2. Inductance measured between secondary pins at 10 kHz, 0.06 Vrms, 0 Adc. 3. Primary DCR is measured with the windings connected in parallel. 4. Maximum volt-time product is for the secondary, based on 2000 Gauss. 5. Primary current of 30 A causes less than 25°C temperature rise from 25°C ambient. Higher current causes a greater temperature rise (see Temperature Rise vs Current curve). 6. Terminating resistance (RT) value is based on 1 Volt output with 30 Amps flowing through the primary. Varying terminating resistance increases or decreases output Voltage/Ampere according to the following equation: RT = Vout × Nsec / Iin. 7. Electrical specifications at 25°C. Refer to Doc 362 “Soldering Surface Mount Components” before soldering. Typical Circuit Specifications subject to change without notice. Please check our website for latest information. Document 1103-1 Revised 10/30/14 Document 1103-2 SCS Series Current Sense Transformers Temperature Rise vs Current Dimensions Dimensions are in inches mm Document 1103-2 Revised 10/30/14