Data Sheet - SI-EPF006640WW

Product Data Sheet
Rev. 4.0
1#
2015.03.20
LED Driver
Indoor 15 W Dimmable
SI-EPF006640WW
Constant Current LED Driver
Wide Operating Range up to 0.5 A – Dimmable
Features & Benefits
• Output Current Range:
0.18 ~ 0.5 A
(adjustable via LEDset)
• Output Voltage Range:
20 ~ 50 Vdc
• Output Power Range:
3.6 ~ 15 W
• Dimming Control:
0-10 V
• Input Voltage:
120 ~ 277 Vac,
• Safety:
UL / cUL (UL 60950 + UL 8750)
• EMI:
FCC Part 15 Class B
50/60 Hz
• Protections:
Overload, No Load, Short Circuit, Over Temperature,
Over Voltage
• ta Range:
-20 ~ +50 °C
• Expected lifetime:
50,000 hours at ta = 50 °C
• Long lasting & high reliability
• Small compact housing
Applications
• Downlights, Spotlights and other Indoor Lighting Applications
• Office – Industry – Shop
2
Table of Contents
1.
Characteristics
-----------------------
3
2.
Typical Characteristics Graphs
-----------------------
5
3.
Protection
-----------------------
7
4.
Dimming Specification
-----------------------
8
5.
Reliability
-----------------------
8
6.
Outline Drawing & Dimension
-----------------------
9
7.
Label Structure
-----------------------
10
8.
Packing Structure
-----------------------
10
9.
Precautions in Handling & Use
-----------------------
11
3
1. Characteristics
Specification
Article
Symbol
Unit
Min.
Typ.
Note
Max.
INPUT SPECIFICATIONS
Nominal Voltage
Vin
Voltage Range
120 ~ 277
108
Nominal Frequency
fin
Frequency Range
Vac
305
50 / 60
47
Full input range, no range switching
Vac
Hz
63
Hz
At 120 Vac
Iin
0.18
A
At full load
At 277 Vac
Iin
0.08
A
At full load
THD
20
%
At Po>12 W, 120-277 Vac
-
At Po>12 W, 120-277 Vac
%
At full load, 120-277 Vac
W
At <1 V dimming voltage, 120-277 Vac
Input Current
Total Harmonic Distortion
Power Factor
Efficiency
PF
0.9
η
83
86
Stand-by Power
1
Protection Class
2
In-rush Current
20
Apk
Cold or hot start (twidth = 350 μs
measured at 50 % Ipk) at 277 Vac
Vdc
±2 %;
Vdc
Open circuit, No-load protection
OUTPUT SPECIFICATIONS
Nominal Voltage
Vo
20 ~ 50
Max. Voltage
55
Nominal Current
Io
0.18 ~ 0.5
Nominal Power
Po
3.6 ~ 15
Turn-on Delay Time
Td
at Io = 0.18-0.5 A
A
±5 % (0.5 A), ±10 % (0.18 A)
15
W
At Io = 0.18-0.5 A, Vo = 20-50 V
1
s
At full load, 108 Vac input
4
Specification
Article
Symbol
Unit
Min.
Typ.
Note
Max.
DIMMING SPECIFICATIONS
Dimming Control
0-10 V
See Dimming Specification section
ENVIRONMENTAL SPECIFICATIONS
50
ºC
90
ºC
Measured at tc point as indicated on
the product label
-25
80
ºC
Cool down before operating
20
90
%
Not condensing
L/N
±1
kV
LN / GND
±2
kV
Ambient Temperature
ta
Case Temperature
tc
Storage Temperature
ts
Relative Humidity
Surge Transient
Protection
-20
According to IEC/EN 61547
IP Rating
20
Expected Lifetime (e-cap)
MTBF
Dimensions
Net Weight
-
Suitable for indoor environment
50,000
h
At ta = 50 ºC, full load, 120-277 Vac
100,000
h
At ta = 25 ºC, full load, 120-277 Vac
4.8 x 3.1 x 1.3
inch
123 x 79 x 33
mm
240
g
LxWxH
± 25 g
2. Typical Characteristics Graphs
a) Operating Window
b) Efficiency vs. Load
Efficiency versus Output Power
100%
90%
80%
70%
y
c 60%
n
ie
icf 50%
f
E 40%
Eff@120Vac_Iout=0.5A
Eff@277Vac_Iout=0.5A
Eff@120Vac_Iout=0.18A
Eff@277Vac_Iout=0.18A
30%
20%
10%
0%
20V
25V
30V
35V
40V
45V
50V
Vout
c) Power Factor vs. Load
d) Total Harmonic Distortion vs. Load
Power Factor versus Output Power
THD versus Output Power
1.10
30%
1.05
25%
1.00
r
ot 0.95
c
a
F 0.90
r
e
w 0.85
o
P 0.80
PF@120Vac_Iout=0.5A
PF@277Vac_Iout=0.5A
PF@120Vac_Iout=0.18A
PF@277Vac_Iout=0.18A
THD@120Vac_Iout=0.5A
D 20%
H
T
15%
THD@277Vac_Iout=0.5A
THD@120Vac_Iout=0.18A
10%
THD@277Vac_Iout=0.18A
5%
0.75
0%
0.70
20V
25V
30V
35V
Vout
40V
45V
50V
20V
25V
30V
35V
Vout
40V
45V
50V
e) Current Setting
The output current can be adjusted using Rset resistor:
•
Disconnect Rset resistor to set full load at 0.5 A / 30 V condition
•
Connect Rset resistor to set output current (see below table and curve);
for Rset = 3.9 kOhm, the output is full load at
0.3 A / 50 V condition
•
The unit has minimum output current at 0.18 A when the Rset is 1 kOhm or less
•
The output voltage is limited by maximum output power (if the output current is set at 0.5 A, the maximum output voltage
will be 30 V; if the output current is set at 0.3 A, the maximum output voltage will be 50 V)
Output vs. Rset Curve
3. Protection
a) Output Short Circuit Protection
The unit is protected when output is short thus avoiding fire hazard, shock hazard and damage to the unit.
After the short circuit fault condition is removed, the unit will be in auto recovery mode.
b) Output Over Voltage Protection
When no load condition occurs, the unit will clamp output voltage to the OVP Voltage avoiding damage to the unit.
After the load is connected, the unit will be in auto recovery mode.
The OVP Voltage varies according to the Rset resistor value (see below curve and table) and under 55 V.
c) Over Temperature Protection
The unit is protected when IC is over 140 °C thus avoiding fire hazard and shock hazard.
down, the unit will be in auto recovery mode.
After the temperature is cooled
Output Current by Dimming
6. Outline Drawing & Dimension
a) Dimension (mm)
Housing material:
b) Wiring
Connectors type (input and output):
DN250A or compatible
Wire cross-section:
0.5 - 1.5 mm2
Wire peeling length:
7 - 9.5 mm
SGCC
7. Label Structure
8. Packing Structure
Dimension (mm)
Packing material
Max. quantity (pcs)
Outer Box
Pallet
20
960
(48 outer boxes)
Length
Width
Height
483
385
108
1220
1020
120
11
9. Precautions in Handling & Use
1) To prevent the LED Driver from any defect, please handle and store it with care
•
Do not drop or give shock
•
Do not store in very humid location or at extreme temperature
•
Do not open or disassemble the product
2) Static electricity or surge voltage may damage the components inside LED Driver, as such please observe proper antielectrostatic working process
•
People handing the Driver should be well grounded (e.g. using ESD wrist band) and wear anti-static working
clothes and gloves
•
All related devices and instruments in the production line should be well grounded (e.g. working table,
measuring equipment, assembly jigs)
3) Observe the correct polarity of output terminal
4) Avoid input voltage exceeds the maximum rating, which will cause damage to the circuit and result in malfunction
Legal and additional information.
About Samsung Electronics Co., Ltd.
Samsung Electronics Co., Ltd. inspires the world and shapes the future
with transformative ideas and technologies, redefining the worlds of TVs,
smartphones, wearable devices, tablets, cameras, digital appliances,
printers, medical equipment, network systems and semiconductors.
We are also leading in the Internet of Things space through, among others,
our Digital Health and Smart Home initiatives. We employ 307,000 people
across 84 countries. To discover more, please visit our official website at
www.samsung.com and our official blog at global.samsungtomorrow.com.
Copyright © 2015 Samsung Electronics Co., Ltd. All rights reserved.
Samsung is a registered trademark of Samsung Electronics Co., Ltd.
Specifications and designs are subject to change without notice. Non-metric
weights and measurements are approximate. All data were deemed correct
at time of creation. Samsung is not liable for errors or omissions. All brand,
product, service names and logos are trademarks and/or registered trademarks
of their respective owners and are hereby recognized and acknowledged.
Samsung Electronics Co., Ltd.
95, Samsung 2-ro
Giheung-gu
Yongin-si, Gyeonggi-do, 446-711
KOREA
www.samsungled.com