Model 15 Multidial

Model 15 Multidial
www.vishay.com
Vishay Spectrol
Mounting Instructions
PRINCIPLES OF OPERATION
The left-hand numeral of the Model 15 Multidial indicates the total number of revolutions of the drive sleeve (component shaft)
that have been completed. The center numeral and right numeral indicate tenths and hundredths of a revolution, respectively.
The graduations between the numerals on the right digit wheel can be read to one five-hundredth of a revolution of the drive
sleeve.
Example: If the reading in the window displays 652, the reading is 6 turns plus 52 % of the seventh turn. Use of the graduations
can further subdivide the reading at this setting.
MOUNTING INSTRUCTIONS
The following instructions apply when the Model 15 is panel-mounted in conjunction with Spectrol 500 or 800 series
potentiometers or other rotary components:
1. Provide a hole in the panel for the non-turn lug on the rear of the dial. The preferred dimensions are shown in the mounting
hole pattern outline overleaf.
2. Mount the potentiometer or component to the panel.
3. Prepare the Model 15 Multidial for mounting by:
a. Rotating the dial to the desired reading.
b. Locking the brake.
c. Removing the spring-detented knob with a straight pull to expose the mounting set screws.
4. Place the dial over the component shaft and engage the non-turn lug into the hole provided in step 1.
5. Rotate the exposed component shaft to phase the component output to the preselected dial reading.
6. Tighten the set screws against the component shaft, replace the spring-detented knob, and release the brake.
7. The dial is now ready to operate.
Removable knob exposes end of
component shaft for precise phasing.
Knob covers mounting set screws
to give unit smooth, unblemished
appearance.
Nonturn lug
Model 15 dial
Flats on knob and hub
key parts together
Dial nonturn lug hole
(Ø 0.128") drilled 0.750"
above centerline of
component mounting hole
Knob is removed by a
firm outward pull
Potentiometer
Springs snap over rib
on hub of dial to
hold knob in place
Set screws attach dial
to component shaft
Panel
Shaft of component is
exposed for accurate
effortless phasing to
dial reading
Potentiometer
locating lug hole
0.125 (3.17)
0.084 (2.13)
0.750
(19.05)
+ 0.003
Ø 0.128 - 0.001
+ 0.08
(3.25 - 0.03 )
(No. 30 drill)
0.750
(19.05)
Ø 0.495 Ø 0.695
(12.57) (17.65)
CL Component
shaft hole
+ 0.002
Mounting hole pattern
Rear view
Ø 0.250 - 0.000
(6.35 +- 00.05 )
Dimensions in inches (millimeters)
Revision: 10-Aug-12
Document Number: 57108
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000