2016.1.26 3VD-XL

Test Report.
No. CANEC1600814069
Date: 26 Jan 2016 .
Page 1 of 7.
HANGZHOU SILAN INTEGRATED CIRCUIT CO.,LTD. .
NO.308,10TH ROAD,EAST HETZ,HANGZHOU
CHINA.
.
The following sample(s) was/were submitted and identified on behalf of the clients as : 3VD(XL) .
SGS Job No. :
CP16-001874 - GZ .
Date of Sample Received : .
13 Jan 2016.
Testing Period : .
13 Jan 2016 - 20 Jan 2016 .
Test Requested : .
Selected test(s) as requested by client. .
Test Method : .
Please refer to next page(s). .
Test Results :.
Please refer to next page(s). .
Conclusion :.
Based on the performed tests on submitted sample(s), the results of Lead,
Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs),
Polybrominated diphenyl ethers (PBDEs) and Phthalates such as
Bis(2-ethylhexyl) phthalate (DEHP) , Butyl benzyl phthalate (BBP), Dibutyl
phthalate (DBP) , and Diisobutyl phthalate (DIBP) comply with the limits as set by
RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. .
Signed for and on behalf of
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch.
Trophy Zhang.
Approved Signatory .
Kenny Wang.
Approved Signatory .
Test Report.
No. CANEC1600814069
Date: 26 Jan 2016 .
Page 2 of 7.
Test Results :.
Test Part Description : .
Specimen No..
SN1.
SGS Sample ID.
CAN16-008140.010
Description.
"3VD(XL)".
Remarks :.
(1) 1 mg/kg = 0.0001% .
(2) MDL = Method Detection Limit .
(3) ND = Not Detected ( < MDL ) .
(4) "-" = Not Regulated .
RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.
Test Method : . (1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.
(4)With reference to IEC 62321:2008, determination of Hexavalent Chromium by Colorimetric
Method using UV-Vis.
(5)With reference to IEC 62321-6:2015, determination of PBBs and PBDEs by GC-MS.
(6)With reference to EN 14372:2004, determination of phthalates by GC-MS. .
Test Item(s).
Limit.
Unit.
MDL.
010.
Cadmium (Cd) .
100
mg/kg.
2
ND
Lead (Pb).
1,000
mg/kg.
2
ND
Mercury (Hg).
1,000
mg/kg.
2
ND
Hexavalent Chromium (CrVI) .
1,000
mg/kg.
2
ND
Sum of PBBs .
1,000
mg/kg.
-
ND
Monobromobiphenyl .
-
mg/kg.
5
ND
Dibromobiphenyl .
-
mg/kg.
5
ND
Tribromobiphenyl .
-
mg/kg.
5
ND
Tetrabromobiphenyl .
-
mg/kg.
5
ND
Pentabromobiphenyl .
-
mg/kg.
5
ND
Hexabromobiphenyl .
-
mg/kg.
5
ND
Heptabromobiphenyl .
-
mg/kg.
5
ND
Octabromobiphenyl .
-
mg/kg.
5
ND
Nonabromobiphenyl .
-
mg/kg.
5
ND
-
mg/kg.
5
ND
1,000
mg/kg.
-
ND
Decabromobiphenyl .
Sum of PBDEs .
Test Report.
No. CANEC1600814069
Date: 26 Jan 2016 .
Limit.
Unit.
MDL.
010.
Monobromodiphenyl ether .
-
mg/kg.
5
ND
Dibromodiphenyl ether .
-
mg/kg.
5
ND
Tribromodiphenyl ether .
-
mg/kg.
5
ND
Tetrabromodiphenyl ether .
-
mg/kg.
5
ND
Pentabromodiphenyl ether .
-
mg/kg.
5
ND
Hexabromodiphenyl ether .
-
mg/kg.
5
ND
Heptabromodiphenyl ether .
-
mg/kg.
5
ND
Octabromodiphenyl ether .
-
mg/kg.
5
ND
Nonabromodiphenyl ether .
-
mg/kg.
5
ND
Decabromodiphenyl ether .
-
mg/kg.
5
ND
Dibutyl phthalate (DBP) .
1,000
mg/kg.
30
ND
Butyl benzyl phthalate (BBP) .
1,000
mg/kg.
30
ND
Bis (2-ethylhexyl) phthalate (DEHP) .
1,000
mg/kg.
30
ND
Diisobutyl Phthalates (DIBP) .
1,000
mg/kg.
30
ND
Test Item(s).
Notes :.
(1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863. .
Hexabromocyclododecane (HBCDD).
Test Method : . With reference to IEC 62321:2008, analysis was performed by GC-MS. .
Test Item(s).
Hexabromocyclododecane (HBCDD) .
Unit.
MDL.
010.
mg/kg.
10
ND
Page 3 of 7.
Test Report.
No. CANEC1600814069
Date: 26 Jan 2016 .
Page 4 of 7.
ATTACHMENTS
Pb/Cd/Hg/Cr6+/PBBs/PBDEs Testing Flow Chart
1) Name of the person who made testing: Bruce Xiao / Sunny Hu
2) Name of the person in charge of testing: Bella Wang / Cutey Yu
3) These samples were dissolved totally by pre-conditioning method according to below flow chart
(Cr6+ and PBBs/PBDEs test method excluded ).
Sample Preparation
Sample Measurement
Pb/Cd/Hg
Acid digestion with
microwave/ hotplate
Sample solvent
extraction
Filtration
Concentration/
Dilution of extraction
solution
Solution
Residue
Filtration
1) Alkali Fusion /
Dry Ashing
2) Acid to
dissolve
ICP-OES/AAS
DATA
Cr6+
PBBs/PBDEs
GC-MS
DATA
Nonmetallic
material
Metallic
material
Adding digestion
reagent
Boiling water
extraction
Heating to
90~95℃ for
extraction
Filtration and
pH adjustment
Adding 1,5diphenylcarbazide
for color
development
UV-Vis
DATA
Adding 1,5diphenylcarbazide
for color
development
UV-Vis
DATA
Test Report.
No. CANEC1600814069
ATTACHMENTS
Phthalates Testing Flow Chart
1) Name of the person who made testing: Sunny Hu
2) Name of the person in charge of testing: Cutey Yu
Sample cutting / preparation
Sample Measurem ent
Solvent extraction
Concentration/Dilution
Filtration
GC-MS
DATA
Date: 26 Jan 2016 .
Page 5 of 7.
Test Report.
No. CANEC1600814069
ATTACHMENTS
HBCDD Testing Flow Chart
1) Name of the person who made testing: Sunny Hu
2) Name of the person in charge of testing: Cutey Yu
Sample cutting / preparation
Sample Measurement
Solvent extraction
Concentration/Dilution
Filtration
GC-MS
DATA
Date: 26 Jan 2016 .
Page 6 of 7.
Test Report.
No. CANEC1600814069
Date: 26 Jan 2016 .
Sample photo: .
CANEC1600814069
CAN16-008140.010 .
SGS authenticate the photo on original report only .
*** End of Report *** .
Page 7 of 7.