Test Report. No. CANEC1603240909 Date: 15 Mar 2016 . Page 1 of 7. HANGZHOU SILAN MICROELECTRONICS CO.,LTD . NO.4 HUANGGUSHAN ROAD,HANGZHOU,ZHEJIANG CHINA. . The following sample(s) was/were submitted and identified on behalf of the clients as : SDIP-24 . SGS Job No. : CP16-010639 - GZ . Model No. :. SA2111C. Date of Sample Received : . 07 Mar 2016. Testing Period : . 07 Mar 2016 - 14 Mar 2016 . Test Requested : . Selected test(s) as requested by client. . Test Method : . Please refer to next page(s). . Test Results :. Please refer to next page(s). . Conclusion :. Based on the performed tests on submitted sample(s), the results of Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs) and Phthalates such as Bis(2-ethylhexyl) phthalate (DEHP) , Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP) , and Diisobutyl phthalate (DIBP) comply with the limits as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. . Signed for and on behalf of SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch. Echo Yeung. Approved Signatory . Kenny Wang. Approved Signatory . Test Report. No. CANEC1603240909 Date: 15 Mar 2016 . Page 2 of 7. Test Results :. Test Part Description : . Specimen No.. SN1. SGS Sample ID. CAN16-032409.009 Description. Black plastic w/ chip & brown printing . SN2. CAN16-032409.010 Silvery metal pin . Remarks :. (1) 1 mg/kg = 0.0001% . (2) MDL = Method Detection Limit . (3) ND = Not Detected ( < MDL ) . (4) "-" = Not Regulated . RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Test Method : . (1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES. (2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES. (3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES. (4)With reference to IEC 62321:2008, determination of Hexavalent Chromium by Colorimetric Method using UV-Vis. (5)With reference to IEC 62321-6:2015, determination of PBBs and PBDEs by GC-MS. (6)With reference to EN 14372:2004, determination of phthalates by GC-MS. . Test Item(s). Limit. Unit. MDL. 009. Cadmium (Cd) . 100 mg/kg. 2 ND Lead (Pb). 1,000 mg/kg. 2 ND Mercury (Hg). 1,000 mg/kg. 2 ND Hexavalent Chromium (CrVI) . 1,000 mg/kg. 2 ND Sum of PBBs . 1,000 mg/kg. - ND Monobromobiphenyl . - mg/kg. 5 ND Dibromobiphenyl . - mg/kg. 5 ND Tribromobiphenyl . - mg/kg. 5 ND Tetrabromobiphenyl . - mg/kg. 5 ND Pentabromobiphenyl . - mg/kg. 5 ND Hexabromobiphenyl . - mg/kg. 5 ND Heptabromobiphenyl . - mg/kg. 5 ND Octabromobiphenyl . - mg/kg. 5 ND Nonabromobiphenyl . - mg/kg. 5 ND Decabromobiphenyl . - mg/kg. 5 ND Test Report. No. CANEC1603240909 Date: 15 Mar 2016 . Test Item(s). Limit. Unit. Sum of PBDEs . MDL. 009. 1,000 mg/kg. - ND Monobromodiphenyl ether . - mg/kg. 5 ND Dibromodiphenyl ether . - mg/kg. 5 ND Tribromodiphenyl ether . - mg/kg. 5 ND Tetrabromodiphenyl ether . - mg/kg. 5 ND Pentabromodiphenyl ether . - mg/kg. 5 ND Hexabromodiphenyl ether . - mg/kg. 5 ND Heptabromodiphenyl ether . - mg/kg. 5 ND Octabromodiphenyl ether . - mg/kg. 5 ND Nonabromodiphenyl ether . - mg/kg. 5 ND Decabromodiphenyl ether . - mg/kg. 5 ND Dibutyl phthalate (DBP) . 1,000 mg/kg. 30 ND Butyl benzyl phthalate (BBP) . 1,000 mg/kg. 30 ND Bis (2-ethylhexyl) phthalate (DEHP) . 1,000 mg/kg. 30 ND Diisobutyl Phthalates (DIBP) . 1,000 mg/kg. 30 ND Page 3 of 7. Notes :. (1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863. . RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Test Method : . (1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES. (2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES. (3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES. (4)With reference to IEC 62321-7-1:2015 , determination of Hexavalent Chromium by Colorimetric Method using UV-Vis. . Test Item(s). Limit. Unit. MDL. 010. Cadmium (Cd) . 100 mg/kg. 2 ND Lead (Pb). 1,000 mg/kg. 2 8 Mercury (Hg). 1,000 mg/kg. 2 ND -. µg/cm². 0.10 ND Hexavalent Chromium (Cr(VI))▼ . Notes :. (1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863. (2) ▼= a. The sample is positive for CrVI if the CrVI concentration is greater than 0.13 μg/cm2. The sample coating is considered to contain CrVI b. The sample is negative for CrVI if CrVI is ND (concentration less than 0.10 μg/cm2). The coating is considered a non-CrVI based coating c. The result between 0.10 μg/cm2 and 0.13 μg/cm2 is considered to be inconclusive - Test Report. No. CANEC1603240909 Date: 15 Mar 2016 . Page 4 of 7. unavoidable coating variations may influence the determination Information on storage conditions and production date of the tested sample is unavailable and thus Cr(VI) results represent status of the sample at the time of testing. IEC 62321 series is equivalent to EN 62321 series http://www.cenelec.eu/dyn/www/f? p=104:30:1742232870351101::::FSP_ORG_ID, FSP_LANG_ID:1258637,25 . Test Report. No. CANEC1603240909 Date: 15 Mar 2016 . Page 5 of 7. ATTACHMENTS Pb/Cd/Hg/Cr6+/PBBs/PBDEs Testing Flow Chart 1) Name of the person who made testing: Bruce Xiao / Sunny Hu 2) Name of the person in charge of testing: Bella Wang / Cutey Yu 3) These samples were dissolved totally by pre-conditioning method according to below flow chart (Cr6+ and PBBs/PBDEs test method excluded ). Sample Preparation Sample Measurement Pb/Cd/Hg Acid digestion with microwave/ hotplate Sample solvent extraction Filtration Concentration/ Dilution of extraction solution Solution Residue Filtration 1) Alkali Fusion / Dry Ashing 2) Acid to dissolve ICP-OES/AAS DATA Cr6+ PBBs/PBDEs GC-MS DATA Nonmetallic material Metallic material Adding digestion reagent Boiling water extraction Heating to 90~95℃ for extraction Filtration and pH adjustment Adding 1,5diphenylcarbazide for color development UV-Vis DATA Adding 1,5diphenylcarbazide for color development UV-Vis DATA Test Report. No. CANEC1603240909 ATTACHMENTS Phthalates Testing Flow Chart 1) Name of the person who made testing: Sunny Hu 2) Name of the person in charge of testing: Cutey Yu Sample cutting / preparation Sample Measurem ent Solvent extraction Concentration/Dilution Filtration GC-MS DATA Date: 15 Mar 2016 . Page 6 of 7. Test Report. No. CANEC1603240909 Date: 15 Mar 2016 . Sample photo: . CANEC1603240909 CAN16-032409.009 . CANEC1603240909 CAN16-032409.010 . SGS authenticate the photo on original report only . *** End of Report *** . Page 7 of 7.