G3R/G3RD Solid State Relays Same Shape as SSR Type G2R Power Relay for PCB Mounting • Direct mounting to PCBs. Also standardized with input indicator. • High dielectric strength of 2,500 VAC for 2-A models. • High-voltage DC version also available. RoHS Compliant Refer to "Solid State Relays Common Precautions". ■List of Models Terminals Isolation Zero cross function Indicator Rated output load Yes Yes PCB Yes No 2 A at 100 to 240 VAC *2 Minimum packing unit G3R-102PLN G3R-202PN 5, 12, 24 VDC G3R-202PLN 1.5 A at 5 to 110 VDC − Photocoupler Model G3R-102PN 2 A at 100 to 120 VDC *1 No Phototriac Rated input voltage 20 pcs G3RD-101PN 2 A at 4 to 48 VDC *3 G 3 R / G 3 R D G3RD-X02PN Note: Refer to the "List of Certified Models" for UL, CSA, and EN approved models. *1. Product is labelled “125 VAC”. *2. Product is labelled “250 VAC”. *3. Product is labelled “50 VDC”. ■Ratings Input (AC Output With Zero Cross Function) Model Item Rated voltage G3R-102PN G3R-202PN Must release voltage level Input impedance 5 VDC Operating voltage 4 to 6 VDC Must operate voltage level 3.5 VDC max. 0.375 VDC min. 250 Ω±20% 12 VDC 9.6 to 14.4 VDC 8.4 VDC max. 0.9 VDC min. 600 Ω±20% 24 VDC 19.2 to 28.8 VDC 16.8 VDC max. 1.8 VDC min. 1.5 kΩ±20% Input (AC Output Without Zero Cross Function, DC Output) Model Item Rated voltage G3R-102PLN G3R-202PLN G3RD-X02PN G3RD-101PN Operating voltage Must operate voltage level Must release voltage level Input impedance 5 VDC 4 to 6 VDC 3.5 VDC max. 0.375 VDC min. 300 Ω±20% 12 VDC 9.6 to 14.4 VDC 8.4 VDC max. 0.9 VDC min. 750 Ω±20% 24 VDC 19.2 to 28.8 VDC 16.8 VDC max. 1.8 VDC min. 1.5 kΩ±20% Output Item Model Applicable load Rated load voltage Load voltage range G3R-102PN G3R-102PLN Load current Inrush current 100 to 120 VAC 75 to 132 VAC 0.1 to 2 A * G3R-202PN G3R-202PLN 100 to 240 VAC 75 to 264 VAC 0.1 to 2 A * G3RD-X02PN 4 to 48 VDC 3 to 52.8 VDC 0.01 to 2 A * 8 A (10 ms) G3RD-101PN 5 to 110 VDC 3 to 125 VDC 0.01 to 1.5 A * 2.5 A (10 ms) 30 A (60 Hz, 1 cycle) * The applicable output load current varies depending on the ambient temperature. Consult your Omron sales representative for details. ■Characteristics Model Item Operate time Release time G3R-102PLN G3R-102PN G3R-202PLN G3R-202PN G3RD-X02PN G3RD-101PN 1 ms max. 1/2 of load power source cycle + 1 ms max. 1 ms max. 1/2 of load power source cycle + 1 ms max. 1 ms max. 1/2 of load power source cycle + 1 ms max. 1 ms max. 1.6 V (RMS) max. 1.5 V max. Output ON voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient operating temperature Ambient operating humidity Storage temperature Weight 2 mA max. (at 100 VAC) 2 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) 0.1 mA max. (at 50 VDC) 0.1 mA max. (at 125 VDC) 100 MΩ min. (at 500 VDC) 2,500 VAC, 50/60Hz for 1 min. between input and output 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) 1,000 m/s2 –30°C to 80°C (with no icing or condensation) 45% to 85%RH –30°C to 100°C (with no icing or condensation) Approx. 12g (1-A load model), Approx. 18 g (2-A LOAD, DC output model) 1 G3R/G3RD Solid State Relays ■Engineering Data ●Load Current vs. Ambient Temperature Characteristics 2-A Load Model G3R-102P(L)N, G3RD-X02PN, G3R-202P(L)N Load current (A) Load current (A) 1-A Load Model G3RD-101PN 2 2 1.5 1.5 1 1 0.5 0.5 0 −30 −20 0 20 40 60 80 0 −30 −20 100 0 20 40 Ambient temperature (°C) 80 100 30 20 Inrush current (A) Inrush current (A. Peak) ●One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3R-102PN, G3R-102PLN For DC-load G3R-202PN, G3R-202PLN G3RD-101PN G3RD-X02PN Inrush current (A. Peak) G 3 R / G 3 R D 60 Ambient temperature (°C) 3 15 14 13 12 11 10 9 2 8 7 6 10 5 1 4 3 2 0 10 30 50 100 300 5001,000 3,000 0 10 30 50 100 300 500 1,000 Energized time (ms) 1 0 3,000 10 30 50 300 500 1,000ࠉࠉ3,000 100 Energized time (ms) Energized time (ms) ■Dimensions (Unit: mm) G3R-102P@ G3R-202P@ G3RD-101PN G3RD-X02PN Terminal Arrangement/ Internal Connections (BOTTOM VIEW) 13 max. 29 max. − − Input voltage + 29 max. (+) LOAD INPUT + (−) 5 2-1 2-0.5 20.0 3.5 (2.1) 3.5 ● Please refer to “Solid State Relays Common Precautions” for correct use. 2 (+) Load power supply Mounting Holes (BOTTOM VIEW) 1 7.5 ■Safety Precautions Load (−) 4 7.5 2-0.5 3 Note. The plus and minus symbols shown in the parentheses are for DC loads. (0.3) 4 1 20 Four 1.3-dia. holes G3R/G3RD Solid State Relays G 3 R / G 3 R D • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K059-E1-06 0812(0207)(O) 3