Photoelectric sensors FLDK 110G1006/S14 Copy counters dimension drawing 30 50 LED 45 13 M12 x 1 54 98 6 15 ° Laser beam 24 M6 ø 6 110 81 DIP switches 8,5 general data photo measuring distance Sd 0 ... 120 mm optimum operating distance 100 mm counting rate < 600000 copies/h object speed 5 m/sec sensitivity single sheet/edge thickness 0,25 mm sync. input no measuring point visible red laser line 3 mm light source pulsed red laser diode wave length 670 nm laser class 2 edge indicator LED yellow power on indication LED green false pulse suppression on/off switchable connection diagram electrical data voltage supply range +Vs 10 ... 30 VDC current consumption max. (no load) 180 mA (3) (1) +VS output circuit push-pull (1) (4) output output pulse length 5 / 10 ms selectable short circuit protection yes (6) (3) ground reverse polarity protection yes S42 S14 200mA 10Ω polyfuse laser warning mechanical data width / diameter 30 mm type rectangular housing material PA 6 connector base (main connector) M12 x 1, 4 pin front (optics) glass LASER RADIATION DO NOT STARE INTO BEAM Wavelength: 620...680nm Max. av. Output: < 1mW IEC 60825-1, Ed. 2, 2007 CLASS 2 LASER PRODUCT Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No. 50, dated June 24, 2007 ambient conditions operating temperature 0 ... +50 °C protection class IP 54 FLDK 110G1006/S14 www.baumer.com 11/11/2015