Surge Components, Inc. 1.. FEATURE 500 Watts peak pulse power per line (tp=8/20us) SOD-323 package Replacement for MLV (0805) Unidirectional configurations Protects one power or I/O port ESD protection > 40 kV Low clamping voltage RoHS compliant Transient protection for data lines to IEC 61000-4-2(ESD) ± 15KV (air), ± 8KV(contact); IEC 6100-4-4(EFT) 40A (5/50ns) IEC 6100-4-5 (surge): 24A, 8/20us-Level 2 (line-ground) & Level 3 (line-line) 2. APPLICATION Laptop computers Cellular phones Digital cameras PDAs 3. ELECTRICAL CHARACTERISTICS PER LINE@25℃ ℃(UNLESS OTHERWISE SPECIFIED) Parameter Symbol Conditions Min. Typ. Max. Units 5 V Reverse stand-off voltage VRWM Reverse Breakdown voltage VBR Reverse Leakage Current IR VRWM =5V 1 µA Clamping Voltage VC IPP =1A tp=8/20µs 9.8 V Clamping Voltage VC IPP =42A tp=8/20µs 14.5 V Junction Capacitance Cj VR =0V, f =1MHZ It =1mA 2 6.0 V 300 pF 95 East Jefryn Blvd Deer Park, NY 11729 (631) 595-1818 Surge Components, Inc. 4. ABSOLUTE MAXIMUM RATING @25℃ ℃ Rating Symbol Value Units Unidirectional Peak Pulse Power(tp=8/20µs) PPP 500 W Tj -55 to +150 ℃ TSTG -55 to +150 ℃ Operating Temperature Storage Temperature 5.TYPICAL CHARACTERISTICS 3 95 East Jefryn Blvd Deer Park, NY 11729 (631) 595-1818 Surge Components, Inc. 6. PRODUCT DIMENSION AND PAD SIZE. DIM Min. Max A 1.60 1.80 B 1.15 1.45 C 0.80 1.00 D 0.25 0.40 D1 *0.4 D2 *0.5 E 0.15 e *2.20 H 0.00 0.10 J 0.089 0.18 K 2.30 2.70 Tipical Unit: mm 7..PACKING INFORAMTION Min. Max DIM Ao 1.42 1.62 Bo 2.80 3.00 Ko 1.25 1.45 Po 3.90 4.10 P1 3.90 4.10 P2 1.95 2.05 T 0.24 0.27 E 1.65 1.85 F 3.45 3.55 Do 1.40 1.60 D1 0.75 1.25 W 7.90 8.30 G *2.08 H *1.07 I *0.84 a1 5” a2 8” Tipical Unit: mm 4 95 East Jefryn Blvd Deer Park, NY 11729 (631) 595-1818