A u d i o Tr a n s f o r m e r D a t a / Vo i c e C o u p l i n g T Y- 3 1 0 P Description: The TY series transformers are used for a variety of applications including impedance matching, isolation, repeat coil, line balancing, bridging and hybrid circuits. Electrical Specifications at 25º C: Impedance Max. DC Typ. Typ. Typ. Freq. (Ohms) Current Insertion Return Response Pri Sec (mA) 600 600 0 Loss (dB) Loss (dB) 1.0 26 (dB) ±.5 Designed to meet FCC Part 68 Longitudinal Balance: (FCC 68.310) – 60 dB min. 200 – 1000 Hz 45 dB min. 1000 – 4000 Hz .50 MAX Dielectric Strength: (FCC 68.304) – 1500VAC .125 TYP Power Level: -45 dBm to +7 dBm .040 DIA. Frequency Range: Data/Voice = 300 to 3500 Hz Data = 800 to 3500 Hz .86 MAX .468 Schematic: 4 1 PRIMARY SECONDARY 600 600 OHM OHM 3 1 3 6 4 .73 MAX .468 6 RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. *Upon printing, this document is considered “uncontrolled”.Please contact Triad Magnetics website for the most current version. web:www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 Publish Date: December 4, 2013