Datasheet

A6A
Rotary DIP Switch
Sealed Rotary DIP Switch with Various
selections for Code-setting.
● Top/Side-visible. Flat/Cone shaped/Extendedactuator models available.
● A slider lock and rotating PCB mechanism ensure
stable contact reliability.
● Sealed structure equivalent to IP64 (IEC-60529)
prevents flux penetration and provides high contact reliability even in dusty locations.
RoHS Compliant
■List of Models
Type (actuation color)
No. of
switching
positions
10
16
Extended actuator
wheel type (white)
Wheel type
(White with Black
Wheel)
Cone type (black)
Flat type (white)
BCD Decimal
A6A-10R
A6A-10RF
A6A-10RS
A6A-10RW
BCD Decimal complement
A6A-10C
A6A-10CF
A6A-10CS
A6A-10CW
BCD Hexadecimal
A6A-16R
A6A-16RF
A6A-16RS
A6A-16RW
BCD Hexadecimal complement
A6A-16C
A6A-16CF
A6A-16CS
A6A-16CW
Quantity
per box
Output code
100
Note: 1. Contact your OMRON sales representative to request special markings or designations.
2. Order in multiples of the package quantity.
■Ratings/Characteristics
Rating (resistive load)
0.1 A at 28 VDC
1 mA (minimum current) at 5 VDC
Ambient operating temperature
–10 to +70°C 60%RH max. (with no icing or condensation)
Ambient operating humidity
45% to 85%RH (at +5 to +35°C)
Insulation resistance
10 MΩ min. (at 250 VDC with insulation tester)
Contact resistance (initial value)
Dielectric strength
200 mΩ max.
Between terminals 250 VAC for 1 min
Vibration resistance
Malfunction
Shock resistance
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
300 m/s2 min.
Durability
Electrical
2,000 steps min.
Washing
Possible
Degree of protection
Internally sealed (IEC IP64)
Operating torque
1.18 to 2.45 × 10−2 N·m {1.2 to 2.5 gf·m}
Weight
Cone: Approx. 0.8 g
Flat: Approx. 0.7 g
Extended actuator: Approx. 0.8g
Wheel: Approx. 1.0g
1
A6A
A6A
■Output Codes
10-position Models
Type
Terminal No.
Position
16-position Models
BCD Decimal
complement code
BCD Decimal code
1
2
4
1
3
●
●
●
●
●
●
0
●
●
●
1
●
●
2
●
●
3
●
4
●
●
●
●
●
●
●
●
●
●
●
●
8
9
8
●
●
6
7
4
●
4
5
2
●
2
●
Terminal No.
1
8
0
Type
●
●
Position
●
5
●
6
●
7
●
●
8
●
●
9
1
2
B
4
●
●
4
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
8
●
●
E
F
2
1
●
C
D
8
●
A
Note: “●” indicates that the internal switch is ON.
BCD Hexadecimal
complement code
BCD Hexadecimal code
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Note: “●” indicates that the internal switch is ON.
(Unit: mm)
● Cone Type, 16 Positions
A6A-16R
10
A6A-16C
7 8 9
5
4
6
10
2
8
9
1
0
B CDE
3
A
7
4
10
3 4 5 6
● Cone Type, 10 Positions
A6A-10R
10
A6A-10C
F 0 1
0.7±0.2
(slot depth: 0.9)
1 2
1
3
4
0
(5.9)
7.5±0.2
3.2
(0.3)
0.2
7.62
(5.9) 7.5±0.2
(0.3)
0.2
0.6
● Flat Type, 10 Positions
A6A-10RF
A6A-10CF
789
2
10 4 dia. (3.4)
10
0
B C DE
7 8
2 3
5 6
2.54 2.54
A
4
9
1
10 4 dia. (3.4)
● Flat Type, 16 Positions
A6A-16RF
A6A-16CF
10
0.7
(slot depth: 0.9)
0 1
0.7
(slot depth: 0.9)
5.9
6.2 +0.3
-0.4
5.9
6.2 +0.3
-0.4
(0.3)
3.2
0.2
7.62
0.6
2.54 2.54
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2
3.2
0.6
7.62
2.54 2.54
3456
0
0.7±0.2
(slot depth: 0.9)
F
9
4
2
■Dimensions
(0.3)
3.2
0.2
7.62
0.6
2.54 2.54
A6A
A6A
2 3
3456
2
0
B C DE
7 8
10
789
A
5 6
4
9
1
10
● Extended Actuator Type, 16 Positions
A6A-16RS
10
A6A-16CS
F
● Extended Actuator Type, 10 Positions
A6A-10RS
10
A6A-10CS
4 dia.
0 1
0.7
0.7
0.9
0.9
7.3
0.2
7.62
7.3
5.9
5.9
(0.3)
3.2
(0.3)
3.2
0.2
7.62
0.6
0.6
2.54 2.54
2.54 2.54
● Wheel Type, 16 Positions
A6A-16RW
10
A6A-16CW
E
1
F
9.5 dia.
0.7
0 9
0.9
7.3
0
0
4 dia.
0.7
8 9
DCBA
8 7
10
1 2
1
2
0.2
7.62
3
5432
3 2
10
98 7
6
5 4
1
● Wheel Type, 10 Positions
A6A-10RW
10
A6A-10CW
6
4 dia.
0.9
7.3
DE F 0 1 23
4
9.5 dia.
4 dia.
12 3 4 5 67
5.9
5.9
(0.3)
3.2
(0.3)
3.2
0.6
2.54 2.54
0.2
7.62
0.6
2.54 2.54
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
■PCB Dimensions (Top View)
(Single-sided PCB, t = 1.2 to 1.6)
0.8-dia. holes
(0.9 dia. for automatic insertion)
7.62±0.1
5.08±0.1
2.54±0.1
2.54±0.1
■Internal Connections
Contact Form (Top View)
1
4
C
2
8
■Precautions
Be sure to read the Safety precautions common to all DIP Switches for correct use.
3
A6A
A6A
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
4
Contact: www.omron.com/ecb
Cat. No. A213-E1-02
1014(0207)(O)