Downloads for PC Mount Split Pack™ Power Transformers (F10-1200)

P OWE R T RAN S FO R M E R
P C M O U N T : SPLIT PACK
F10-1200
Description:
The F10-1200 is a single primary and dual secondary, split bobbin design which
operates with an input of 115V. The output voltage will be either 10.0V with a
center-tap under a 1.2A load with the secondaries wired in series, or 5.0V under
a 2.4A load with the secondaries wired in parallel. The split bobbin design
eliminates the need for costly electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 12.0VA
2. Primary:
115V
3. Secondary: Series: 10.0V CT@ 1.2A
Parallel: 5.0V @ 2.4A
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 2500 VRMS
W
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling.
Agency File:
E
UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
Canadian Use (CSA 22.2, No.66.2-06)
L
This model is also available in Class 2, UL 5085-3 (1585) version as F10-1200-C2
H
Dimensions:
H
W
1.437 1.562
Weight: 0.70 lbs
Units in inches.
L
1.875
A
0.300
B
0.400
C
1.410
D
0.041
E
0.020
F
0.234
1
4
D
F
Schematic:
5
A
1
115V
50/60Hz
4
A
5
6
7
8
B
8
C
RoHS Compliance: As of manufacturing date February 2005, all standard products
meet the requirements of 2011/65/EU, known as the RoHS initiative.
1
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2
and 5085-3, respectively.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
4
0.06" DIAMETER
HOLE
Board Layout
Publish Date: December 4, 2013
CLASS 2 TRANSFORMER
F10-1200-C2
Description:
The F10-1200-C2 is a single primary and dual secondary, split bobbin design which
operates with an input of 115V. The secondaries are 5V @ 1.2A each. They can
be used independently (up to 300V difference between them) or in series for double
the voltage or in parallel for double the current. The split bobbin design eliminates
the need for costly electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 12.0VA
2. Primary: 115V
3. Secondaries: 5.0V @ 1.2A each
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25° C TYP
6. Hipot tested 100% at 4200 VRMS pri to sec
7. Hipot tested 100% at 2160 VRMS sec to sec
8. Recommended fuse (fuse on primary): Cooper/Bussman, Type MDL, rated
500mA, 250V
W
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling. UL Class F Insulation System (155°C).
E
Agency File:
UL: File E65390, UL 5085-1 & 3 (1585), Class 2 Transformer
cUL: File E65390, UL 5085-1 & 3 (1585) For Canadian Use (CSA 22.2, No.66.3-06)
L
H
Dimensions:
H
W
1.437 1.562
Weight: 0.70 lbs
Units in inches.
L
1.875
A
0.300
B
0.400
C
1.410
D
0.041
E
0.020
4
1
F
0.234
D
F
Schematic:
5
A
5V @ 1.2A
1
115V
50/60 Hz
4
A
5
6
7
8
B
5V @ 1.2A
8
C
RoHS Compliance: As of manufacturing date February 2005, all standard products
meet the requirements of 2011/65/EU, known as the RoHS initiative.
1
Note: Order and shipping documentation may have a “-B” suffix; this indicates Bulk
packaging but does not show on the actual part number marked on the transformer.
4
0.06" DIAMETER
HOLE
Board Layout
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
www.TriadMagnetics.com
Phone: (951) 277-0757
Fax: (951) 277-2757
460 Harley Knox Blvd.
Perris, CA 92571
Publish Date: December 4, 2013