www.osram.com/prevaled 03/2016 Technical application guide PrevaLED® Cube G3 LED modules Light is OSRAM PrevaLED ® Cube G3 LED modules | Contents Contents 1 Introduction 03 4 Thermal considerations 11 1.1 System overview 03 4.1 Thermal power values 11 1.2 Nomenclature 03 4.2 Operating current as a function of temperature 11 4.3 Thermal protection features 12 2 Optical considerations 04 4.4 TIM and other accessories 12 2.1 Light distribution 04 4.5 Cooling system and heat sink 13 2.2 Reflector design 04 4.6 tc point location and temperature measurement 13 2.3 Color temperature 05 4.7 Thermocouple 14 2.4 Color rendering 05 2.5 Spectral distribution 06 5 Lifetime and thermal behavior 15 2.6 Luminous flux behavior 06 5.1 Luminous flux as a function of temperature 15 5.2 Lifetime 16 3 Electrical considerations 07 3.1 Forward voltage as a function of temperature 07 6 Mechanical considerations 17 3.2 Driver compatibility 07 6.1 Outline drawing 17 3.3 Wiring 08 6.2 3D drawing 17 3.4 OTi DALI LED drivers 09 6.3 Mechanical protection of the light engine 17 3.5 OT FIT LED drivers 09 6.4 Mounting 17 3.6 OTe LED drivers 09 3.7 LEDset2 (LT2) 10 7 Norms and standards 18 3.8 ESD 10 Please note: All information in this guide has been prepared with great care. OSRAM, however, does not accept liability for possible errors, changes and/or omissions. Please check www.osram.com or contact your sales partner for an updated copy of this guide. This technical application guide is for information purposes only and aims to support you in tackling the challenges and taking full advantage of all opportunities the technology has to offer. Please note that this guide is based on own measurements, tests, specific parameters and assumptions. Individual applications may not be covered and need different handling. Responsibility and testing obligations remain with the luminaire manufacturer/OEM/ application planner. 2 PrevaLED ® Cube G3 LED modules | Introduction 1 Introduction 1.1 System overview Building an LED-based luminaire poses a set of technical challenges, among them optical requirements, providing adequate thermal management for stable operation and dealing with the improving performance of LEDs. Nevertheless, LED technology also provides an unknown number of possibilities, opening up unprecedented levels of performance. OSRAM’s PrevaLED® family of LED light engines addresses the challenges of LED-based lighting while providing users with great performance and flexibility at the same time. Enabled by the application of LED technology, PrevaLED® is aiming to push the envelope of what is possible in terms of performance and simplicity. PrevaLED® Cube G3 LED light engines offer one of the best and easiest ways to outfit luminaires with LED technology. They are ideally suited for use in highly diffuse wall-mounted and ceiling-mounted luminaires in decorative, hospitality or domestic application as well as a broad range of wide- reflector-based luminaires such as downlights. Future-proof concept To allow for a smooth transition to this new generation of the PrevaLED® Cube series, crucial features have remained the same: —— Complete portfolio in terms of luminous flux, color temperature and color rendering —— Same form factor and mechanical/optical interfaces as previous generation —— High driver flexibility allows cost-effective and intelligent systems —— 5-year guarantee (for current terms and conditions of the guarantee, please visit www.osram.com/systemguarantee) —— Selection of dimmable and non-dimmable LED drivers Of course, important improvements have been realized as well: —— High flexibility through four lumen packages and four color temperatures: The PrevaLED® Cube G3 series is available as a 1 100 lm, 2 000 lm, 3 000 lm and soon 5 000 lm package in two light colors (3 000 K and 4 000 K); further light colors (2 700 K and 3 500 K) and the PrevaLED® Cube G3 board version are available upon request through your sales partner —— Low height of optical contact area (OCA) of 18.6 mm for compact luminaire design —— Near Lambertian light distribution for best quality of light in diffuser as well as reflector-based applications —— Industry-standard mounting holes and light-emitting surface (LES) for use with standard heat sink and reflector accessories —— Lifetime (L70B50) at tc = 80 °C: 50 000 hours —— Improved poke-in connector for stranded and solid wires —— Very good light quality —— Very high efficiencies for smaller heat sinks and easier thermal management —— Typical module efficacy: up to 135 lm/W —— tc max: 90 °C —— Thermal protection —— Thermal derating with LEDset2 —— Thermal shutdown 1.2 Nomenclature PL-CUBE: PrevaLED® Cube family 1100: 1100 lm 8: CRI > 80 27: Color temperature, 2700 K G3: Generation 3 PL-CUBE-1100-827-G3 3 PrevaLED ® Cube G3 LED modules | Optical considerations 2 Optical considerations 2.1 Light distribution The light distribution of PrevaLED® Cube G3 light engines is shown below. They create a beam angle of 110° FWHM. For optics support, you can find our partners via OSRAM’s LED Light for You network: www.ledlightforyou.com. Moreover, standard components and support for reflector design are available e.g. through the following suppliers: The PrevaLED® Cube G3 board version has an even wider beam angle of 120° FWHM. Light distribution curve Jordan Reflektoren GmbH & Co. KG Schwelmer Strasse 161, 42389 Wuppertal, Germany +49 202 60720 [email protected] www.jordan-reflektoren.de ACL-Lichttechnik GmbH Hans-Boeckler-Strasse 38 A, 40764 Langenfeld, Germany +49 2173 9753 0 [email protected] www.reflektor.com Jordan Luxar GmbH & Co. KG Schneiderstrasse 76 d, 40764 Langenfeld, Germany Phone: +49 (0)2173 279-0, Fax: +49 (0)2173 279-250 [email protected] www.jordan-luxar.de 2.2 Reflector design The light-emitting surface of the light engines is covered by a diffuser to ensure a homogenous, smooth light distribution. Please ensure that the temperature of the diffuser does not exceed 120 °C. PrevaLED® Cube G3 light engines can also be used with secondary optics. As their optical interface has the same dimensions as common downlight modules in the market, they can be combined with available off-the shelf secondary optics. OSRAM provides mechanical (3D files) and optical simulation data (ray files) to support customized reflector design. Ray file data are available upon request through your sales partner. Almeco S.p.A. Via della Liberazione, 15, 20098 San Giuliano Milanese (Mi), Italy +39 02 988963 1 [email protected] www.almecogroup.com Nata Lighting Co., Ltd. 380 Jinou Road, Gaoxin Zone, Jiangmen City, Guangdong, China +86 750 377 0000 [email protected] www.nata.cn Widegerm Lighting Ltd. Flat A, 3/F., Tak Wing Ind. Building 3 Tsun Wen Rd. Tuen Mun, N.T., Hong Kong +85 224 655 679 [email protected] www.widegerm.com.hk 4 PrevaLED ® Cube G3 LED modules | Optical considerations Color coordinates 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The color coordinates within the CIE 1931 color space are given below. y Three-step MacAdam ellipses 0.42 Initial color vales of the CCT 2700 K 3000 K 0.41 2700 K 3000 K 3500 K 4000 K Cx 0.464 0.439 0.412 0.387 Cy 0.412 0.405 0.394 0.384 3500 K 0.40 4000 K 0.39 Within each available color temperature, the PrevaLED® Cube G3 series provides a maximum color variation of three threshold value units (MacAdam steps). The diagram on the right shows these threshold values within the CIE 1931 color space. 0.38 0.37 0.37 0.39 0.41 0.43 0.45 0.47 x These color coordinates apply to PrevaLED Cube G3 incl. housing ® 2.4 Color rendering PrevaLED® Cube G3 LED modules provide a color rendering index (CRI) of > 80. The table below shows the indivi dual Ra values from R1 to R14 for the available color temperatures. Dusky pink Mustard yellow Yellowish green Light green Turquois Azure Aster violet Lilac violet Red, s aturated Yellow, s aturated Green, s aturated Blue, s aturated Pink, skin color Leaf green General CRI R a values R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 Ra CCT = 2700 K 79 91 95 78 79 90 81 55 5 80 76 74 82 98 81 CCT = 3000 K 80 90 97 79 80 87 83 59 7 77 78 69 82 99 82 CCT = 3500 K 81 90 97 80 81 87 85 62 9 77 78 66 83 99 83 CCT = 4000 K 81 90 96 81 81 85 87 65 12 75 80 63 83 98 83 Typical values of PrevaLED Cube G3 with 2000 lm ® 5 PrevaLED ® Cube G3 LED modules | Optical considerations 2.5 Spectral distribution The typical spectral distribution of the PrevaLED® Cube G3 LED modules is shown in the following diagram. Wavelength spectrum 827 Realtive spectral emission [% · 100] 830 835 840 1.00 0.80 0.60 0.40 0.20 0.00 400 450 500 550 600 650 700 750 800 850 Wavelength [nm] 2.6 Luminous flux behavior The following diagrams show the luminous flux as a function of the operating current for PrevaLED® Cube G3 LED modules with 1 100 lm, 2 000 lm and 3 000 lm. The data related to the operating current is derived from a tp temperature of 75 °C. PL-CUBE-1100-G3 PL-CUBE-2000-G3 Flux normalized at rated current [%] Flux normalized at rated current [%] 150 150 100 100 50 50 0 0 0 100 200 300 400 500 600 700 If [mA] 0 100 200 300 400 500 600 700 800 If [mA] PL-CUBE-3000-G3 Flux normalized at rated current [%] 160 140 120 100 80 60 40 20 0 0 200 400 600 800 1000 If [mA] 6 PrevaLED ® Cube G3 LED modules | Electrical considerations 3 Electrical considerations 3.1 Forward voltage as a function of temperature PL-CUBE-1100-G3 PL-CUBE-2000-G3 Uf typ [V] Uf typ [V] 33.0 23.5 32.5 23.0 32.0 22.5 31.5 22.0 31.0 21.5 30.5 -20 0 20 40 60 80 100 tc [°C] -20 0 20 40 60 80 100 tc [°C] PL-CUBE-3000-G3 Uf typ [V] 33.0 32.5 32.0 31.5 31.0 30.5 -20 0 20 40 60 80 100 tc [°C] 3.2 Driver compatibility PL-CUBE-3000-840 PL-CUBE-3000-830 PL-CUBE-2000-840 PL-CUBE-2000-830 PL-CUBE-1100-840 PL-CUBE-1100-830 Drivers OTe 13/220-240/350 PC OTe 25/420 CS OTe 35/700 CS OT FIT 25/500 CS OT FIT 35/700 CS OTi DALI 15 LT2 OTi DALI 25/700 LT2 OTi DALI 35/1A0 LT2 OT FIT 15/500 LT2 OT FIT 25/700 LT2 OT FIT 40/1A0 LT2 Modules Compatibility of PrevaLED® Cube with OPTOTRONIC® tested compatibility preliminary compatibility Note: For the maximum allowed number of LED drivers per circuit breaker, please see the datasheet of the driver at www.osram.com/ot. 7 PrevaLED ® Cube G3 LED modules | Electrical considerations 3.3 Wiring The used input clamps can handle solid or flexible wire with a cross-section of 0.2 to 0.75 mm2 (AWG 24–18). The use of solid wire is recommended. Example: H05V-U 1x 0.5 mm2 Wire preparation 6–7 mm (0.24–0.28 inches) Notes: —— The connector is designed for three “poke-in” and release cycles. —— The installation of LED modules has to be carried out in compliance with all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. Solid wire Plug directly. Flexible wire 1. L ightly press the push button of the connection clamp. 2. Insert the flexible wire. To press/release the clamps, please use an operating tool (Wago type: 206-860) or a small screwdriver. 8 PrevaLED ® Cube G3 LED modules | Electrical considerations 3.4 OTi DALI LED drivers If you use the PrevaLED® Cube G3 series in combination with the OSRAM OTi DALI LED driver series, you will get the best results and the full functionality of the LED module. 3.6 OTe LED drivers If you want to use the OSRAM OTe series, please connect the terminal LED+ to the LED module and select the desired current by connecting it to only one of the output terminals 21, 22 or 23. The system includes a one-wire communication interface, using the LEDset2 communication standard between the LED driver and the LED module. A thermal derating and a luminous flux calibration are included. Therefore, please connect all three terminals of the module to the LED driver. OTe 35/220-240/700 CS OTi DALI 50/220-240/1A4 LT2 FAN 3.5 OT FIT LED drivers It is also possible to use the PrevaLED® Cube G3 series with a constant-current LED driver. The OT FIT series offers different available currents. To wire the LED module to the LED driver, please connect the terminals LED+ and LED- to the LED module as shown in the image below. The current is selected by a bridge between ports 3, 4 and 5. The new OT FIT LT2 drivers will also support the LEDset2 functionality as explained above in chapter 3.4. OT FIT 25/220-240/500 CS 9 PrevaLED ® Cube G3 LED modules | Electrical considerations 3.7 LEDset2 (LT2) LEDset helps you to meet important market requirements: —— Future-proof solutions in terms of luminous flux —— Long-life operation —— Luminaire customization —— Energy and cost savings 3.8 ESD It is not necessary to handle PrevaLED® Cube G3 LED modules with housing in electrostatic protected areas (EPAs). To protect a PrevaLED® Cube G3 LED module from electrostatic damage, do not open it. The PrevaLED® Cube G3 board version without housing must be handled in electrostatic protected areas. LEDset2 (LEDset generation 2) is the enhanced interface between OPTOTRONIC® LED drivers and LED modules (such as OSRAM PrevaLED®). It can be identified by the product name of the LED driver, including the letters “LT2” at its end. LEDset2 is based on a three-wire connection between the LED driver and the LED module. This interface is designed to allow communication between the LED module and the LED driver, performing LED current setting and thermal protection functionality. Combined with PrevaLED® Cube G3 LED modules, the interface supports the following functionalities: —— Absolute output current setting of the constant-current LED driver (LED module self-recognition) —— Thermal protection of the LED module LEDset2 allows a selection of the output current through the simple selection of the proper Rset resistor value and the connection of a potentiometer or a fixed standard resistor to the LEDset line. The relationship Iout vs. Rset is defined by the following formula: Iout [A] = 5 V x 1000 Rset [Ω] Note: More detailed information about the possibilities of LEDset2 interfaces can be found in the corresponding driver application guidelines and at www.osram.com/ledset. 10 PrevaLED ® Cube G3 LED modules | Thermal considerations 4 Thermal considerations The proper thermal design of an LED luminaire is critical for achieving the best performance and ensuring the longest lifetime of all components. Due to the high efficacy of PrevaLED® Cube G3 light engines, only a partial amount of the introduced electrical power has to be dissipated through the back of the light engine. The thermal power that has to be dissipated for PrevaLED® Cube G3 light engines is given below. 4.1 Thermal power values Product reference Rated input current [mA] Typical thermal power at rated input current [W]* Max. thermal power at Max. allowable thermal rated input current [W]* resistance at rated input current (R th [K/W])** PL-CUBE-1100-827-G3 394 5.3 6.2 13.2 PL-CUBE-1100-830-G3 371 4.8 5.6 13.5 PL-CUBE-1100-835-G3 371 4.8 5.6 13.5 PL-CUBE-1100-840-G3 371 4.8 5.6 13.5 PL-CUBE-2000-827-G3 476 9.5 11.1 7.3 PL-CUBE-2000-830-G3 449 8.7 10.2 7.5 PL-CUBE-2000-835-G3 449 8.7 10.2 7.5 PL-CUBE-2000-840-G3 449 8.7 10.2 7.5 PL-CUBE-3000-827-G3 733 15.2 17.7 4.8 PL-CUBE-3000-830-G3 690 13.9 16.2 5.0 PL-CUBE-3000-835-G3 690 13.9 16.2 5.0 PL-CUBE-3000-840-G3 690 13.9 16.2 5.0 * Value measured at the tc point at a reference temperature of 75 °C ** Value measured on the back of the luminaire at an ambient temperature of 25 °C 4.2 Operating current as a function of temperature Maximum rated currents vs. temperature 1100 lm l max [mA] 2000 lm 3000 lm 1200 Note: The lifetime for rated currents and different temperatures are described in the table in chapter 5.2 “Lifetime”. The lifetime will be reduced if the current exceeds rated currents. 85; 1050 1000 For example: A 3 000-lm module can be driven up to 1 050 mA as long as the temperature at the tc point is maintained below 85 °C. The same module should be driven with reduced current if higher case temperatures are desired. In this case, the drive current should not exceed 900 mA at 90 °C. 90; 900 800 85; 750 90; 650 600 90; 612 400 200 0 70 75 80 85 90 95 tc [°C] The above chart indicates the maximum drive currents including ripple at a desired temperature at the tc point. 11 PrevaLED ® Cube G3 LED modules | Thermal considerations 4.3 Thermal protection features To achieve the best possible lifetime of the LED module and to save it from damage by overheating, thermal protection features have been integrated. The thermal protection of the PrevaLED® Cube G3 LED module is divided into two parts: The first part of the thermal protection is a thermal derating function that works in combination with LED drivers with LEDset2 functionality. It protects the LED module from overheating by communicating with the LED driver (the LEDset port of the LED module must be connected to the LED driver). The system reduces the current of the LED module if critical temperatures are reached. This results in the best possible performance and lifetime of the LED module. The characteristic of the thermal derating function is shown in the graph “Thermal derating with LEDset2”. The second part is a reversible onboard thermal fuse that prevents the module from damage by overheating. This feature does not require LEDset2. If the temperature at the tc point exceeds the maximum allowed value by approx. 20 °C, the thermal fuse is triggered and the module shuts off completely. The thermal fuse can be reset by disconnecting the mains and repowering. The characteristic of the shut-off is shown in the graph “Thermal shut-off without LEDset2”. Thermal derating with LEDset2 Current [% of minimal LED driver current] Thermal shut-off without LEDset2 Current [% of minimal LED driver current] 100 0 102 110 116 tc [°C] 4.4 TIM and other accessories When mounting a PrevaLED® Cube G3 light engine within a luminaire, it is recommended to use thermal interface material (TIM) between the back of the light engine and the luminaire housing or heat sink. It is recommended to use thermal paste. In order to balance possible unevenness, the material should be applied as thinly as possible, but as thickly as necessary. In this way, air inclusions, which may otherwise occur, are replaced by TIM and the required heat conduction between the back of the light engine and the contact surfaces of the luminaire housing is achieved. For this purpose, the planarity and roughness of the surface should be optimized. The list below is a selection of suppliers of thermal interface materials. Additional suppliers for thermal management support can also be found via OSRAM’s LED Light for You network at www.ledlightforyou.com or at www.osram.com. 100 50 0 tc max Thermal interface materials 105 tc [°C] The behavior below 50 % of the system current depends on the nominal system current and the applied LED driver. Company Website Alfatec www.alfatec.de Kerafol www.kerafol.de Laird www.lairdtech.com Bergquist www.bergquistcompany.com Arctic Silver www.arcticsilver.com Wakefield www.wakefield.com 12 PrevaLED ® Cube G3 LED modules | Thermal considerations Total power dissipation of the LED module, max. ambient temperature ta, max. reference temperature tr according to lifetime requirements Define boundary conditions Rth = Estimate heat sink thermal resistance on LED module level tr - ta Pth Location of the tc point 41.4 All figures in mm tr measured at the tc point Use the estimated Rth as a target for a possible heat sink profile and examine the performance curve in the heat sink manufacturer’s catalog. Select heat sink thermal resistance 4.6 tc point location and temperature measurement The tc point is the location where to check if the chosen cooling solution (heat sink) is sufficient to ensure the LED module performance. The tc point is located on the back of the LED module under the center of the light-emitting surface (see following image). 37.3 4.5 Cooling system and heat sink For the selection of a suitable heat sink, several points regarding thermal resistance have to be considered. The selection is usually carried out through the following necessary steps. Notes: A thermal design must always be confirmed by performing a thermal measurement in steady-state condition. The whole area of the PCB must be in full contact with the heat sink. tc point To enable a lifetime of 50 000 (L70B50), the reference temperature (tr) at the tc point must not exceed 80 °C. The maximum temperature reached at the tc point must not exceed 90 °C. A correct temperature measurement can, for example, be performed with a thermocouple. The list below is a selection of suppliers of different cooling solutions. Supplier of active and passive cooling systems Company Website Nuventix www.nuventix.com Sunon www.sunon.com Cooliance www.cooliance.eu AVC www.avc-europa.de SEPA www.sepa-europe.com Wakefield-Vette www.wakefield-vette.com Fischer Elektronik www.fischerelektronik.de Wakefield www.wakefield.com MechaTronix www.mechatronix-asia.com 13 PrevaLED ® Cube G3 LED modules | Thermal considerations 4.7 Thermocouple Use a thermocouple that can be glued onto the LED module. Make sure that the thermocouple is fixed with direct contact to the tc point. Examples of suitable thermocouples: K-type thermocouple with miniature connector Different thermocouples Mounting of a thermocouple through a hole in the heat sink Illustration Description Temperature range [°C] PVC-insulated thermoc ouple -10 … +105 PFA-insulated thermoc ouple -75 … +260 Sprung thermoc ouple -75 … +260 To measure the temperature and to ensure a good thermal coupling between the LED module and the heat sink, you should drill a hole into the heat sink and push the thermocouple through it. To ensure a direct contact between the thermocouple and the PCB, it is recommended to glue the thermocouple onto the PCB. You can, for example, use an acrylic adhesive (e.g. type Loctite 3751). Mounting of a PFA-insulated thermocouple by means of a groove It is also possible to use a sprung thermocouple. A suitable type is: Electronic Sensor FS TE-4-KK06/09/2m. Please note that a good thermal contact between the thermocouple and the PCB is required. Please refer to the datasheet and the application guideline of the manufacturer to ensure correct handling. Another possible way is to create a small groove along the top surface of the heat sink and run the thermocouple to the tc point inside the groove. Notes: Please keep in mind that you need a direct contact between the thermocouple and the PCB. If you use TIM, you should cut out a small area where the thermocouple has direct contact to the PCB. 14 PrevaLED ® Cube G3 LED modules | Lifetime and thermal behavior 5 Lifetime and thermal behavior 5.1 Luminous flux as a function of temperature The following diagrams show the behavior of the luminous flux output as a function of the temperature at the tc point for PrevaLED® Cube G3. PL-CUBE-1100-G3 PL-CUBE-2000-G3 Flux normalized at rated current [%] Flux normalized at rated current [%] 115 115 110 110 105 105 100 100 95 95 90 90 -20 30 80 130 tc [°C] -20 0 20 40 60 80 100 120 tc [°C] PL-CUBE-3000-G3 Flux normalized at rated current [%] 115 110 105 100 95 90 -20 30 80 130 tc [°C] 15 PrevaLED ® Cube G3 LED modules | Lifetime and thermal behavior 5.2 Lifetime The performance of PrevaLED® Cube G3 light engines is measured at a typical tc of 75 °C. The maximum temperature at the tc point must not exceed 80 °C to achieve the expected lifetime (L70B50) of 50 000 hours. The maximum temperature at the tc point to cover the operational warranty of the light engine is 90 °C. A warranty of 5 years can only be given if the light engine is not operated above a tc point temperature of 75 °C. Please note that as the tc increases, the lifetime of PrevaLED® Cube G3 light engines decreases. Moreover, the failure rate will also increase. PL-CUBE-DC-1100-G3 L70B50 L80B10 L80B50 L0C10 L0C50 L70F10 L70F50 L80F10 L80F50 Lifetime [h] at t c point = 70 °C 49000 L70B10 50000 32000 46000 >130000 >130000 49000 50000 32000 46000 Lifetime [h] at t c point = 75 °C 43000 50000 28000 40000 >130000 >130000 42000 50000 28000 40000 Lifetime [h] at t c point = 80 °C 38000 50000 25000 35000 >130000 >130000 37000 50000 25000 35000 Lifetime [h] at t c point = 85 °C 33000 49000 22000 31000 >130000 >130000 33000 49000 22000 31000 Lifetime [h] at t c point = 90 °C 29000 43000 19000 27000 >130000 >130000 29000 43000 19000 27000 PL-CUBE-DC-2000-G3 L70B50 L80B10 L80B50 L0C10 L0C50 L70F10 L70F50 L80F10 L80F50 Lifetime [h] at t c point = 70 °C 49000 L70B10 50000 32000 46000 >130000 >130000 49000 50000 32000 46000 Lifetime [h] at t c point = 75 °C 43000 50000 28000 40000 >130000 >130000 42000 50000 28000 40000 Lifetime [h] at t c point = 80 °C 38000 50000 25000 35000 >130000 >130000 37000 50000 25000 35000 Lifetime [h] at t c point = 85 °C 33000 49000 22000 31000 >130000 >130000 33000 49000 22000 31000 Lifetime [h] at t c point = 90 °C 29000 43000 19000 27000 >130000 >130000 29000 43000 19000 27000 PL-CUBE-DC-3000-G3 L70B50 L80B10 L80B50 L0C10 L0C50 L70F10 L70F50 L80F10 L80F50 Lifetime [h] at t c point = 70 °C 44000 L70B10 50000 29000 42000 >130000 >130000 44000 50000 29000 42000 Lifetime [h] at t c point = 75 °C 39000 50000 25000 36000 >130000 >130000 38000 50000 25000 36000 Lifetime [h] at t c point = 80 °C 34000 50000 22000 32000 >130000 >130000 34000 50000 22000 32000 Lifetime [h] at t c point = 85 °C 30000 44000 20000 28000 >130000 >130000 30000 44000 19000 28000 Lifetime [h] at t c point = 90 °C 26000 39000 17000 25000 >130000 >130000 26000 39000 17000 25000 16 PrevaLED ® Cube G3 LED modules | Mechanical considerations 6 Mechanical considerations The following schematic drawing provides further details on the dimensions of PrevaLED® Cube G3 LED modules. For 3D files of the LED modules, please go to www.osram.com. 18.6 21.1 6.1 Outline drawing 54.4 6.3 Mechanical protection of the light engine The housing of a PrevaLED® Cube G3 LED module should not be exposed to strong mechanical stress. Please apply force only to the dedicated mounting positions. Strong mechanical stress can lead to irreversible damage of the LED module. 6.2 (screw contact area) 41.4 kg Tc 82.8 37.3 68 81.6 61 4.3 All figures in mm Note: General mechanical tolerances according to ISO 2768 c. 6.2 3D drawing For operation in damp, wet or dusty environments, the user has to make sure that an adequate ingress protection (IP) is chosen. The LED module has to be protected by a suitable IP rating of the luminaire housing. Please consider the luminaire standard IEC 60598-1 as well as the different requirements for indoor and outdoor application. 6.4 Mounting To fix a PrevaLED® Cube G3 light engine to a heat sink, you may use M4 cylinder head screws according to DIN 912 or ISO 4762. The recommended torque is 1.0 ± 0.5 Nm. Enable 3D View Move me! Movable 3D PrevaLED ® Cube G3 LED module (works with Adobe Acrobat 7 or higher) Mount the LED module from the top 17 PrevaLED ® Cube G3 LED modules | Norms and standards 7 Norms and standards Safety: IEC/EN 62031 UL 8750 Class 2 Photobiological safety: IEC/EN 62471 Risk group 1 Ingress protection: IP20 (no ingress protection without housing) Approvals: CE, UL, VDE ENEC Disclaimer All information contained in this document has been collected, analyzed and verified with great care by OSRAM. However, OSRAM is not responsible for the correctness and completeness of the information contained in this document and OSRAM cannot be made liable for any damage that occurs in connection with the use of and/or reliance on the content of this document. The information contained in this document reflects the current state of knowledge on the date of issue. 18 03/16 OSRAM LLS SSL-OEM-EM Subject to change without notice. Errors and omissions excepted. www.osram.com/prevaled OSRAM GmbH Head office: Marcel-Breuer-Strasse 6 80807 Munich, Germany Phone +49 89 6213-0 Fax +49 89 6213-2020 www.osram.com