P OWER TRANSFORMER P C MOUNT: WORLD SERIES VPP12–4400 Electrical Specifications (@25C) 1. Maximum Power: 56.0VA 2. Input: Series: 230VAC, 50/60Hz; Parallel: 115VAC, 50/60Hz 3. Output: Series: 12.6V CT@ 4.4A; Parallel: 6.3V @ 8.8A 4. Voltage Regulation: 25% TYP @ full load to no load 5. Temperature Rise: 30C TYP (45C MAX allowed) 6. Insulation Resistance: 100MΩ 7. Hipot: 4000VAC between primary to secondary and windings to core. Construction: Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds UL flammability requirements. Safety: Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required. World Series Transformers are designed and manufactured to meet the following agency approvals: Agency File: UL: File E53148, UL 5085-1 and 2 (formerly UL 506), General Purpose. CSA: File LR 221330. C22.2 NO. 66, General Purpose. TUV: File R72103639, EN 60950, (IEC950) information Technology Equipment. A. Dimensions: Units: In inches H W D A B C ML MD MW 1.812 3.0 2.50 0.600 0.300 1.900 - 2.0 2.5 B. PIN DIM. : 0.045 SQ C. WT Lbs. : 1.70 D. Mounting Holes: 0.180 dia. x 4 Connections1: Input: Series – Pin 1 to Pin 6, Jumper Pin 4 to Pin 3 Parallel – Pin 1 to Pin 6, Jumper Pin 1 to Pin 4 and Pin 3 to Pin 6 Output: Series – Pin 7 to Pin 12, Jumper Pin 9 to Pin 10 Parallel – Pin 7 to Pin 12, Jumper Pin 7 to Pin 10 and Pin 9 to Pin 12 RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. * Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the most current version. 1 Primary and secondary windings are designed to be connected in series or parallel. Winding are not intended to be used independently. Web: www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 6 12 4 10 3 9 1 7 SCHEMATIC Publish Date: December 4, 2013