P OWER TRANSFORMER P C MOUNT: WORLD SERIES VPP24–2330 Electrical Specifications (@25C) 1. Maximum Power: 56.0VA 2. Input: Series: 230VAC, 50/60Hz; Parallel: 115VAC, 50/60Hz 1 2 3. Output: Series : 24.0V CT@ 2.33A; Parallel : 12.0V @ 4.66A 4. Voltage Regulation: 25% TYP @ full load to no load 5. Temperature Rise: 30C TYP (45C MAX allowed) 6. Insulation Resistance: 100MΩ 7. Hipot: 4000VAC between primary to secondary and windings to core. 3 8. Recommended Fuse : Series: Littelfuse p/n 313 2.5HXP, 2.5A 250V, slow blow, ¼ x 1 ¼ or, Cooper Bussmann p/n BKMDL-2½, 2.5A 250V, ¼ x 1 ¼ Parallel: Littelfuse p/n 313 5.0HXP, 5A 250V, slow blow, ¼ x 1 ¼ or, Cooper Bussmann p/n BKMDL-5, 5A 250V, ¼ x 1 ¼ Construction: Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds UL flammability requirements. Safety: Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required. World Series Transformers are designed and manufactured to meet the following agency approvals: Agency File: UL: File E53148, UL 5085-1 and 2 (formerly UL 506), General Purpose. UL: File E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3. CSA: File LR 221330. C22.2 NO. 66, General Purpose. TUV: File R72103639, EN 60950, (IEC950) information Technology Equipment. A. Dimensions: Units: In inches H W D A B C ML MD MW 1.812 3.0 2.50 0.600 0.300 1.900 - 2.0 2.5 B. PIN DIM. : 0.045 SQ C. WT Lbs. : 1.70 D. Mounting Holes: 0.180 dia. x 4 Connections4: Input: Series – Pin 1 to Pin 6, Jumper Pin 4 to Pin 3 Parallel – Pin 1 to Pin 6, Jumper Pin 1 to Pin 4 and Pin 3 to Pin 6 Output: Series – Pin 7 to Pin 12, Jumper Pin 9 to Pin 10 Parallel – Pin 7 to Pin 12, Jumper Pin 7 to Pin 10 and Pin 9 to Pin 12 RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. * Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the most current version. 6 12 1 4 10 2 3 9 Non-Inherently limited. Class 2 not wet, Class 3 wet. Non-Inherently limited. Class 2. 3 Fuse must be used on secondary as conditions of acceptability for UL Class2/3 operation. 4 Primary and secondary windings are designed to be connected in series or parallel. Winding are not intended to be used independently. Web: www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 7 1 SCHEMATIC Publish Date: December 4, 2013