Downloads for Multiple Secondary Chassis Mount Power Transformers (F-198U)

P OWE R T RAN S FO R M E R
Chassis Mount: Multiple Secondary
F-198U
Electrical Specifications (@25C)
1. Maximum Power: 122.0 VA
2. Primary: 115V 50/60 Hz
3. Secondary 1: 32.0VCT @ 1.00 Amps
Secondary 2: 15.5VCT @ 6.00 Amps
4. Voltage Regulation: 5 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-198U is part of a series which has a long history of reliable service in the
field, made from a proven design and constructed with UL recognized materials.
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
BLK
BLK
Safety:
These products are 100% hipot tested with an insulation of 1500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
.203 X .375
D
Dimensions:
MTG SLOTS
Units: In inches
A
B
C
D
E
3.750
3.125
3.187
2.50
2.750
Weight:
6.2 lbs
C
Schematic:
RED
BLK
RED/YEL SEC 1
E
RED
PRIMARY
GRN
BLK
GRN/YEL
SEC 2
RED
GRN
RED/Y
RED
A
GRN
GRN/Y
GRN
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
B
Publish Date: May 11, 2015