Electrical Specifications (@25C)
1. Maximum Power: 126.0 VA
2. Primary: 115V 50/60 Hz
3. Secondary: 6.3V @ 20.0 Amps
4. Voltage Regulation: 10 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-22A is part of a series which has a long history of reliable service in the field,
made from a proven design and constructed with UL recognized materials.
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
A
These products are 100% hipot tested with an insulation of 2000V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
Dimensions:
D
Units: In inches
A
B
C
D
E
F
3.875
3.281
4.125
2.50
3.00
2.00
B
Lead length: 10.0 inches + 1 inch
Weight: 7.0 lbs
F
Schematic:
BLK
GRN
GRN/YEL
E
BLK
C
GRN
Primary:
Black to Black
Secondary: Green to Green
RoHS Compliance: As of manufacturing date February 2005, all standard products meet the
requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
MTG SLOTS
.203 X .375
REF
Publish Date: December 4, 2013