DVI Connectors XM4M Transfer High-resolution Video Signals with OMRON’s DVI-compliant Digital Visual Interface Connectors. ■ Used for both digital video (TMDS) and conven- tional analog (RGB) signals. ■ OMRON’s DVI Connector is an analog interface capable of up to 2.5-GHz bandwidths. ■ Transfers broadband data up to 9.9 Gbps (dual link) to ensure full compatibility with advanced broadband applications. ■ Shielded against EMI for high-speed data transfer. ■ Digital and digital/analog models available. RoHS Compliant ■ Terminology z DVI z bps Abbreviation for Digital Visual Interface. One of the specifications for connecting a PC and display. Using the DVI, you can directly send digital signals from a PC to the display. Abbreviation of Bits Per Second. Unit of data speed expressing the number of bits that can be transmitted in one second. 1 bps means 1 bit of data can be transmitted per second. z TMDS z EMI Abbreviation for Transition Minimized Differential Signaling. A digital transmission method of the display video signal used for the DVI. Abbreviation of ElectroMagnetic Interference (noise). z RGB Three video signals of R (Red), G (Green) and B (Blue). ■ Ordering Information Type Digital Digital/Analog Accessories No anchors Inch screws, length = 5.8 mm No anchors Inch screws, length = 5.8 mm Model XM4M-2432-5012 XM4M-2432-1312 XM4M-2932-5012 XM4M-2932-1312 Appearance ■ Ratings and Characteristics Type Digital Digital/Analog Item Rated current 1.5 A Rated voltage 40 VAC Contact resistance 30 mΩ max. (at 20 mVDC, 100 mA max.) Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength 500 VDC for 1 min (leakage current: 0.5 mA max.) ■ Materials and Finish Housing PBT (UL94 V-0)/natural Cover PBT (UL94 V-0)/natural Contact Mating end Copper alloy/nickel base, gold plating Terminal Copper alloy/nickel base, tin plating Shell Steel/nickel plated Anchors Steel/nickel plated Grounding Fixture Copper alloy/tin plated Insertion durability 100 times Ambient operating − 20 to 85°C (with no condensation or icing) temperature 1 ■ Dimensions (unit: mm) XM4M-2432-1312 Mounting holes (t = 1.6 mm, bottom view) 18.2 5.8 3.3 ±0.05 6.5 24.03 1.905 30.73 ±0.1 19.05 ±0.1 5.84 ±0.05 Board terminals Four, 1.93 +0.1 dia. 0 1.93 ±0.05 Pin 24 1.905 ±0.05 36.78 32.51 17.78 13.335 1.905 #4-40 UNC 1.905 ±0.05 7.72 9.9 32.51 ±0.05 27.43 ±0.05 2.5 1.905 13.335 19.05 30.73 2.03 2.73 3.3 2.7 1.905 ±0.05 13.335 ±0.1 Panel dimensions (For XM4M-2432-501@) (t = 1.2 mm max.) 4.95 1.905 dia. 24, 0.86 +0.1 0 Pin 1 Two, R0.64 ±0.1 dia. Two, 3.05 +0.1 0 9.14 ±0.05 1.905 Two, R2.54 ±0.1 2.54 ±0.05 XM4M-2932-1312 Mounting holes (t = 1.6 mm, bottom view) 30.73 ±0.1 19.05 ±0.1 Board terminals Six, 0.66 +0.1 dia. 0 5.84 ±0.05 Four, 1.93 +0.1 0 dia. 18.2 2.67 ±0.05 3.94 ±0.05 2.54 ±0.05 5.8 6.5 3.3 ±0.05 5.08 ±0.05 24.03 1.27 ±0.05 2.54 ±0.05 24, 0.86 +0.1 dia. 0 1.93 ±0.05 1.905 #4-40 UNC 36.78 32.51 13.335 1.905 1.905 ±0.05 9.9 2.03 1.27 2.54 13.335 19.05 30.73 1.905 ±0.05 13.335 ±0.1 7.72 4.95 1.905 1.905 Pin 1 1.905 ±0.05 1.27 2.54 2.54 1.27 2.73 2.66 3.3 3.94 2.7 Panel dimensions (For XM4M-2932-501@) (t = 1.2 mm max.) 2.5 2.54 5.08 1.905 32.51 ±0.05 27.43 ±0.05 Two, R0.64 ±0.1 dia. Two, 3.05 +0.1 0 9.14 ±0.05 Two, R2.54 ±0.1 2.54 ±0.05 ■ Terminal layout Digital/Analog sharing type terminal Arrangement Terminal layout viewed from the mating surface Terminal 9 Board terminal arrangement (BOTTOM VIEW) Terminal 16 Terminal 1 Terminal 8 Board edge Terminal 17 C1 C2 Terminal 16 C3 C5 Terminal 24 1 8 C1 C3 24 C4 C2 C5 C4 Terminal 9 Terminal 1 Terminal 17 Terminal 24 C3 C5 C4 Terminal 8 C1 C2 C5 Note: The digital type does not have C1 to C5. ■ Precautions Precautions for Correct Use Automated Soldering About panel mount Soldering Use anchor 3 (XM4Z-002@ series) to lock connectors without anchors. (For anchor 3, refer to XM3-L/XM-2L/XM4K/XM4L.) Automated Soldering Conditions (Jet Flow) 1. Soldering temperature: 250 ±5°C 2. Continuous soldering time: Within 5±1 s Tightening torque for anchors To install an anchor on the connector body, tighten it with 0.49 N·m. Also, use a proper size tool to do this work. 2 DVI Connectors XM4M Mating Do not connect the Connectors in the wrong direction, otherwise it may be damaged. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. G061-E1-02 1014(0412)(O)