D2RV Miniature Basic Switch High Reliability for Micro Load Applications, Even in Adverse Atmospheres (Dust, High Humidity, Silicon Gas, etc.) D 2 R V ● The reed switch offers exceptional contact reliability in micro load applications. ● Same mounting pitch as for the V Miniature Basic Switch. ● High durability with a bounce time of 1 ms max. RoHS Compliant Model Number Legend Contact Form 1 @ 2 D2RV- @ ●SPST-NO Reed switch 1. Actuator None : Pin plunger model L11 : Short hinge lever L : Hinge lever L13 : Simulated roller lever L22 : Short hinge roller lever L2 : Hinge roller lever 2. Maximum Operating Force (OF) None : 0.49 N {50 gf} E G : 0.25 N {25 gf} (for pin plungers only) : 0.98 N {100 gf} NO COM Ratings Switching voltage 100 VDC (max.) Switching current 0.25 ADC (max.) Contact capacity 10 WDC (max.) Note. The above rating values apply under the following test conditions. (1) Ambient temperature: 20±2°C (2) Ambient humidity: 65±5% (3) Operating frequency: 30 operations/min Characteristics Note. These values are for the pin plunger models. List of Models Actuator Pin plunger Maximum Operating Force (OF) Model D2RV-E 0.49 N {50 gf} D2RV 0.98 N {100 gf} D2RV-G Short hinge lever 0.49 N {50 gf} D2RV-L11 0.98 N {100 gf} D2RV-L11G Hinge lever 0.25 N {25 gf} D2RV-L 0.49 N {50 gf} D2RV-LG 0.25 N {25 gf} D2RV-L13 0.49 N {50 gf} D2RV-L13G 0.49 N {50 gf} D2RV-L22 0.98 N {100 gf} D2RV-L22G Short hinge roller lever Hinge roller lever 0.1mm to 1 m/s (for pin plunger models) Permissible operating frequency Mechanical 200 operations/min Electrical 200 operations/min Insulation resistance 100 MΩ min. (at 500 VDC with insulation tester) Contact resistance (initial value) 0.25 N {25 gf} Simulated roller lever Permissible operating speed 0.25 N {25 gf} D2RV-L2 0.49 N {50 gf} D2RV-L2G Between terminals of the same polarity Dielectric strength * 1 Between currentcarrying metal parts and 500 VAC 50/60 Hz for 1 min ground Between each terminal and non-currentcarrying metal parts Vibration Malfunction resistance * 2 Shock resistance Durability * 3 150 mΩ max. 200 VDC 1 min 500 VAC 50/60 Hz for 1 min 10 to 55 Hz, 1.5 mm double amplitude Destruction 500 m/s2 {approx. 50G} max. Malfunction * 2 200 m/s2 {approx. 20G} max. Mechanical 10,000,000 operations min. (60 operations/min) Electrical 3,000,000 operations min. (30 operations/min) Degree of protection IEC IP40 Ambient operating temperature –10°C to +60°C (at ambient humidity of 60% max.) (with no icing or condensation) Ambient operating humidity 80% max. (for +5°C to +35°C) Weight Approx. 7g (for pin plunger models) Note. The data given above are initial values. *1. The values for dielectric strength shown are for models with a Separator (refer to "Basic Switch Common Accessories"). *2. For the pin plunger models, the above values apply for use at the free position and total travel position. For the lever models, they apply at the total travel position. Close or open circuit of the contact is 1ms max. *3. For testing conditions, consult your OMRON sales representative. Separator (Sold Separately), Actuator (Sold Separately), Terminal Connector (Sold Separately) Refer to "Basic Switch Common Accessories" 1 D2RV Miniature Basic Switch Terminals/Appearances Mounting Holes (Unit: mm) (Unit:mm) 6.3 2-3.1 dia. mounting holes or M3 screw holes t=0.5 2-Solder terminals 3.2 4.8 10.3±0.1 2.4 dia. 1.3 dia. 22.2±0.1 5.4 15.9 D 2 R V 1 (10) Dimensions (Unit: mm) /Operating Characteristics ●Pin Plunger D2RV-E D2RV D2RV-G A PT OP 5.15 20.2±0.25 R1.5 2.8 3.1+0.13 −0.03 dia. holes 10.3±0.1 Model 4.3 Operating Force 5.4 15.9 ●Short Hinge Lever D2RV-L11 D2RV-L11G 3.4±0.15 dia. 22.2±0.1 2.8 27.8 22.1 A PT OP t=0.5 * 10.3 1 Operating Position (10) 3.1+0.13 −0.03 dia. holes 10.3±0.1 ●Hinge Lever Models D2RV-L D2RV-LG A PT OP 35.6±0.8 t=0.5 * 1 Operating Position * Stainless-steel lever 3.1+0.13 −0.03 dia. holes 10.3±0.1 ●Simulated Roller Lever Models R3.5 D2RV-L13 PT A D2RV-L13G 1 Operating Position * Stainless-steel lever t=0.5 * 8.1 4.3 3.1+0.13 −0.03 dia. holes OP OF Max. OP Operating characteristics Operating Force OF Max. OP 10.3±0.1 5.4 15.9 2.8 3.1+0.13 −0.03 3.4±0.15 dia. 22.2±0.1 2.8 27.8 10.3 1 (10) * Stainless-steel lever Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). 2 D2RV-L11G 0.49 N {50 gf} 0.98 N {100 gf} 1.8 mm 0.4 mm 1.0 mm 15.0±0.6 mm D2RV-L D2RV-LG 0.25 N {25 gf} 0.49 N {50 gf} 4.0 mm 1.0 mm 1.6 mm 14.4±1.2 mm Model 5.15 32.6±0.8 OF Max. D2RV-L11 Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 10.3 (10) 14.4±0.6 mm Operating characteristics Operating Force 2.8 3.4±0.15 dia. 22.2±0.1 2.8 27.8 1.6 mm 0.6 mm 0.8 mm Model 4.3 5.4 15.9 3.1+0.13 −0.03 0.98 N {100 gf} Operating characteristics 5.15 8.1 0.49 N {50 gf} Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 10.3 (10) 0.25 N {25 gf} OP Operating Force 2.8 3.4±0.15 dia. 22.2±0.1 2.8 27.8 D2RV-G Model 4.3 5.4 15.9 3.1+0.13 −0.03 D2RV OF Max. 5.15 8.1 D2RV-E Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 2.8 3.1+0.13 −0.03 Operating characteristics Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. Operating Position OP D2RV-L13 D2RV-L13G 0.25 N {25 gf} 0.49 N {50 gf} 4.0 mm 1.0 mm 1.6 mm 18.1±1.2 mm D2RV Miniature Basic Switch ●Short Hinge Roller Lever Models D2RV-L22 D2RV-L22G PT 4.8 dia.×4.8 *2 5.15 t=0.5 *1 A 20.1 8.1 3.1+0.13 −0.03 dia. holes Model Operating characteristics Operating Force OP 10.3±0.1 5.4 15.9 2.8 3.1+0.13 −0.03 ●Hinge Roller Lever Models D2RV-L2 PT D2RV-L2G 3.4±0.15 dia. 22.2±0.1 2.8 27.8 10.3 1 (10) *1. Stainless-steel lever *2. Polyacetal resin roller t=0.5 *1 A 34±0.8 4.8 dia.×4.8 *2 5.15 8.1 3.1+0.13 −0.03 dia. holes 10.3±0.1 5.4 15.9 2.8 3.1+0.13 −0.03 3.4±0.15 dia. 22.2±0.1 2.8 27.8 10.3 Operating Position (10) 0.49 N {50 gf} 0.98 N {100 gf} 1.8 mm 0.4 mm 1.0 mm OP 20.4±0.6 mm D 2 R V Model Operating characteristics OF Max. D2RV-L2 D2RV-L2G 0.25 N {25 gf} 0.49 N {50 gf} Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. Operating Position 1 D2RV-L22G Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. Operating Force OP OF Max. D2RV-L22 OP 4.0 mm 1.0 mm 1.6 mm 19.9±1.2 mm *1. Stainless-steel lever *2. Polyacetal resin roller Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). Precautions ★Please refer to "Basic Switches Common Precautions" for correct use. Cautions ●Handling Do not drop the Switch or apply strong shock. It may result in internal mechanism damages and may deteriorate the characteristics of the inner Reed Switch. ●Effect of the External Vibration When a vibration of 1 kHz or higher is applied, note that false switching operations may occur due to resonant frequency, even with a low acceleration. ●Soldering • Terminal connections Complete the soldering at the iron tip temperature between 250 to 350°C (60W) within 5 seconds, and do not apply any external force for 1 minute after soldering. Apply minimum amount of flux required. It may result in contact failure once the flux penetrates into the internal part of the Switch. Correct Use ●Effect of the External Magnetic Fields • If two or more switch units are closely installed, mutual interference due to the fringing field will occur, resulting in malfunction. Be sure to keep the gap between the switch units 8 mm or more. • If you install the switch unit on the iron plate, each operating characteristic will change. Therefore, confirm that the interval between the switch units should be 2 mm or more. • Do not use the switch in some area where a strong external magnetic field would be applied, otherwise malfunction will be caused. • Use nonmagnetic brass or stainless steel (SUS304 alloy) screws for installation. Do not use any iron screw. 3 D2RV Miniature Basic Switch D 2 R V • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY 4 Contact: www.omron.com/ecb Cat. No. B056-E1-04 0812(0207)(O)