D2QW Sealed Subminiature Basic Switch Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. D 2 Q W ● Extra-long stroke even without levers. (OT: 2.7 mm) ● Clip contacts with highly reliable slide contact mechanism. ● High temperature resistance up to 85°C and drip-proof structure for wide range of applications environmental resistance required. (Conforms to IP67, except for terminal section.) ● Models available with highly reliable gold-plated contacts. RoHS Compliant Model Number Legend D2QW- @ @ @ @ @ - @ - @ 1 2 1. Cover C: M3-screw Mounting 3 4 5 6 7 4. Contact form 2: SPST-NC 3: SPST-NO 2. Ratings 0: Gold-plated contacts 5 VDC 1 mA~30 VDC 0.1 A 1: Silver-plated contacts 5 VDC 1 mA~30 VDC 0.1 A 3. Actuator 0: Pin plunger 6: Leaf lever 7: Simulated roller leaf lever 8: Bent leaf lever 5. Terminals D : PCB terminals H : Solder terminals M : Molded lead wires downwards ML : Molded lead wires on left-side MR : Molded lead wires on right-side 6. Special Specification 7. Special Industry Specification 1 D2QW Sealed Subminiature Basic Switch List of Models Contact Actuator Terminals PCB Solder Pin plunger Molded lead wires downwards Molded lead wires on left-side D 2 Q W Molded lead wires on right-side PCB Solder Simulated Roller Lever Molded lead wires downwards Molded lead wires on left-side Molded lead wires on right-side PCB Solder Leaf lever Molded lead wires downwards Molded lead wires on left-side Molded lead wires on right-side PCB Solder Bent leaf lever Molded lead wires downwards Molded lead wires on left-side Molded lead wires on right-side 2 Gold plated Contact form Silver plated Model SPST-NO D2QW-C003D D2QW-C103D SPST-NC D2QW-C002D D2QW-C102D SPST-NO D2QW-C003H D2QW-C103H SPST-NC D2QW-C002H D2QW-C102H SPST-NO D2QW-C003M D2QW-C103M SPST-NC D2QW-C002M D2QW-C102M SPST-NO D2QW-C003ML D2QW-C103ML SPST-NC D2QW-C002ML D2QW-C102ML SPST-NO D2QW-C003MR D2QW-C103MR SPST-NC D2QW-C002MR D2QW-C102MR SPST-NO D2QW-C073D D2QW-C173D SPST-NC D2QW-C072D D2QW-C172D SPST-NO D2QW-C073H D2QW-C173H SPST-NC D2QW-C072H D2QW-C172H SPST-NO D2QW-C073M D2QW-C173M SPST-NC D2QW-C072M D2QW-C172M SPST-NO D2QW-C073ML D2QW-C173ML SPST-NC D2QW-C072ML D2QW-C172ML SPST-NO D2QW-C073MR D2QW-C173MR SPST-NC D2QW-C072MR D2QW-C172MR SPST-NO D2QW-C063D D2QW-C163D SPST-NC D2QW-C062D D2QW-C162D SPST-NO D2QW-C063H D2QW-C163H SPST-NC D2QW-C062H D2QW-C162H SPST-NO D2QW-C063M D2QW-C163M SPST-NC D2QW-C062M D2QW-C162M SPST-NO D2QW-C063ML D2QW-C163ML SPST-NC D2QW-C062ML D2QW-C162ML SPST-NO D2QW-C063MR D2QW-C163MR SPST-NC D2QW-C062MR D2QW-C162MR SPST-NO D2QW-C083D D2QW-C183D SPST-NC D2QW-C082D D2QW-C182D SPST-NO D2QW-C083H D2QW-C183H SPST-NC D2QW-C082H D2QW-C182H SPST-NO D2QW-C083M D2QW-C183M SPST-NC D2QW-C082M D2QW-C182M SPST-NO D2QW-C083ML D2QW-C183ML SPST-NC D2QW-C082ML SPST-NO SPST-NC D2QW-C083MR D2QW-C082MR D2QW-C182ML D2QW-C183MR D2QW-C182MR D2QW Sealed Subminiature Basic Switch Contact form ●SPST-NO Characteristics ●SPST-NC COM NO (Black) (Blue) COM (Black) Permissible operating speed C0 series Specification Contact Material Minimum applicable load (see note) 120 operations/min Insulation resistance 100 MΩ min. (at 500 VDC with insulation tester) Dielectric strength Contact Specifications Model Permissible operating frequency Contact resistance (initial value) NC (Red) C1 series Slide Gold plated Silver plated 5 VDC 1mA Ratings Vibration resistance Shock resistance Durability Rated voltage Resistive load 30 VDC 14 VDC 0.1A 10mA Note. The above rating values apply under the following test conditions. (1) Ambient temperature: 20±2°C (2) Ambient humidity: 65±5% (3) Operating frequency: 20 operations/min SPST-NO: 1 mm to 500 m/s SPST-NC: 30 mm to 500 m/s Terminal models 100 mΩ max. Molded lead wire models 150 mΩ max. Between terminals of the same polarity 600 VAC 50/60 Hz 1min Between current-carrying metal parts and ground 1,500 VAC 50/60 Hz 1min Between terminals and non-current-carrying metal parts 1,500 VAC 50/60 Hz 1min Malfunction 10 to 55 Hz, 1.5 mm double amplitude D 2 Q W Durability 1,000 m/s2 {approx. 100G} max. Malfunction 300 m/s2 {approx. 30G} max. Mechanical 500,000 operations min. (30 operations/min) Electrical 30 VDC 0.1 A 200,000 operations min. 14 VDC 10 mA 500,000 operations min. (20 operations/min) Degree of protection IEC IP67 (excluding the terminals) Degree of protection against electric shock Class I Proof tracking index (PTI) 175 Ambient operating temperature –40°C to +85°C (at ambient humidity of 60% max.) (with no icing or condensation) Ambient operating humidity 95% max. (for +5°C to +35°C) Weight Approx. 0.7 g (for pin plunger models) 3 D2QW Sealed Subminiature Basic Switch Mounting Structure and Reference Positions for Operating Characteristics 1.7 dia. 8.3±0.1 (4) (Units: mm) Mounting Hole Dimensions (Reference) 8.2±0.2 5.3±0.2 3 +0.1 0 dia. holes OT M3 Tap (depth 1.5 mm min.) FP OP ia. d ±0.1 3.2 TTP 0 . 3 −0 .1 5.1 3 +0.1 0 dia 8.3±0.1 4.2 13.3±0.2 D 2 Q W Terminals/Appearances (Units: mm) ●PCB terminals SPST-NO <PCB Mounting Dimensions (Reference)> SPST-NC SPST-NO 3-1+0.1 0 3 2-0.9 10.16±0.05 13.3±0.2 5.08±0.05 ●Solder terminals SPST-NO 0.4 2-1.2 2-2 10.16±0.1 3 0.4 9.06 13.3±0.2 ●Molded lead wires Molded lead wires on left-side Molded lead wires on right-side Molded lead wires downwards NC AVSS0.3 (Red) or NO AVSS0.3 (Blue) COM AVSS0.3 (Black) NC AVSS0.3 (Red) or NO AVSS0.3 (Blue) 2.4 5.08±0.1 0.4 1.8 4.53 300±10 dia. holes SPST-NC 3 1.2 2 dia. holes 3 0.4 0.9 1.8 SPST-NC 3-1+0.1 0 12.9 COM AVSS0.3 (Black) 3.9 3.9 3.9 4.1 4.1 4.1 12.9 2.4 12.9 300±10 COM AVSS0.3 (Black) 300±10 NO AVSS0.3 (Blue) (5) 4 D2QW Sealed Subminiature Basic Switch Dimensions (Unit: mm) /Operating Characteristics The illustrations and drawings are for solder terminals models. Refer to "Terminals/Appearances" of the previous page for details on models with Straight PCB terminals. When ordering, replace @ with the code for the terminal that you need. ●Pin plunger D2QW-C@02@ D2QW-C@03@ 1.7 dia. 8.3±0.1 (4) 8.2±0.2 5.3±0.2 OT FP OP TTP 0 0.1 ± 3.2 d 5.1 3 +0.1 0 . 0.1 3− ia. dia 4.2 3 1.8 4.53 2-1.2 2-2 Operating characteristics Model Operating Force OF Max. Overtravel OT Free Position FP Max. 9.2 mm 9.2 mm Operating Position OP 8.7±0.3 mm 8.4±0.3 mm Total Travel Position TTP (5.9) mm (5.9) mm D2QW-C@62@ D2QW-C@63@ D2QW-C@02@ D2QW-C@03@ 1.5 N {153 gf} 1.5 N {153 gf} (2.9) mm (2.7) mm D 2 Q W 0.4 13.3±0.2 ●Leaf lever D2QW-C@62@ D2QW-C@63@ t=0.2 Stainless-steel lever 8.3±0.1 8.2±0.2 5.3±0.2 14 OT FP (0.55) (1.2) OP ±0.1 TTP 3.2 .1 5.1 3 +0.1 0 . 0 3−0 . dia dia 4.2 Operating characteristics Model Operating Force OF Max. 1.7 N {173 gf} 1.7 N {173 gf} Overtravel OT (3.7) mm (3.2) mm Free Position FP Max. 11.5 mm 11.5 mm Operating Position OP 9.8±0.5 mm 9.3±0.5 mm Total Travel Position TTP (6.2) mm (6.2) mm D2QW-C@72@ D2QW-C@73@ 3 2-0.9 0.4 10.16±0.05 13.3±0.2 ●Simulated roller leaf lever D2QW-C@72@ D2QW-C@73@ 8.2±0.2 5.3±0.2 3.4 t=0.2 Stainless-steel lever OT (0.45) FP OP (1.7) . dia TTP ±0.1 3.2 3 +0.1 0 . 0 .1 3−0 5.1 dia Operating characteristics Model Operating Force OF Max. 1.5 N {153 gf} 1.5 N {153 gf} Overtravel OT (3.9) mm (3.5) mm Free Position FP Max. 14.4 mm 14.4 mm Operating Position OP 12.5±0.5 mm 12.0±0.5 mm Total Travel Position TTP (8.7) mm (8.7) mm D2QW-C@82@ D2QW-C@83@ 4.2 3 1.8 4.53 2-1.2 2-2 0.4 13.3±0.2 ●Bent leaf lever D2QW-C@82@ D2QW-C@83@ t=0.2 Stainless-steel lever 8.3±0.1 14 3 8.2±0.2 5.3±0.2 R2 OT (0.55) (1.2) TTP ± 3.2 FP OP Operating characteristics Model Operating Force OF Max. 1.7 N {173 gf} 1.7 N {173 gf} Overtravel OT (3.7) mm (3.2) mm Free Position FP Max. 11.3 mm 11.3 mm Operating Position OP 9.6±0.5 mm 9.1±0.5 mm Total Travel Position TTP (6.0) mm (6.0) mm . 0.1 0 .1 −0 3 3 . dia dia 5.1 +0.1 0 4.2 3 2-0.9 10.16±0.05 13.3±0.2 0.4 5 D2QW Sealed Subminiature Basic Switch Precautions ★Please refer to "Basic Switches Common Switches" for correct use. Cautions ●Degree of Protection D 2 Q W • Do not use this product underwater. Although molded lead wire models satisfy the test conditions for the standard given below, this test is to check the ingress of water into the switch enclosure after submerging the Switch in water for a given time. Satisfying this test condition does not mean that the Switch can be used underwater. • JIS (Japanese Industrial Standards) C0920 (Waterproof test of the electrical machinery/appliance and wiring materials) Degree of protection: 7, Model: Waterproof • IEC (International Electrotechnical Commission) Publication 529 (Degrees of Protection Provided by Enclosures) Degree of protection: IP67 • Do not operate the Switch when it is exposed to water spray, or when water drops adhere to the Switch surface, or during sudden temperature changes, otherwise water may intrude into the interior of the Switch due to a suction effect. • Prevent the Switch from coming into contact with oil and chemicals. Otherwise, damage to or deterioration of Switch materials may result. • Do not use the Switch in areas where it is exposed to silicon adhesives, oil, or grease. Otherwise faulty contact may result due to the generation of silicon oxide. ●Soldering • When soldering the lead wire to the terminal, first insert the lead wire conductor through the terminal hole and then conduct soldering. Complete soldering within 3 seconds using a soldering iron with a capacity of 50 W max and a tip temperature of 300°C max. Also, do not apply external force to the Switch for 1 minute after soldering. Improper soldering involving an excessively high temperature or excessive soldering time may deteriorate the characteristics of the Switch. When performing automatic soldering, solder at 260 °C max and complete soldering with 5 seconds. Pay careful attention so that flux or solder liquid does not flow over the edge of the PCB panel. ●Side-actuated (Cam/Dog) Operation • When using a cam or dog to operate the Switch, factors such as the operating speed, operating frequency, push-button indentation, and material and shape of the cam or dog will affect the durability of the Switch. Confirm performance specifications under actual operation conditions before using the Switch in applications. Correct Use ●Mounting • Turn OFF the power supply before mounting or removing the Switch, wiring, or performing maintenance or inspection. Failure to do so may result in electric shock or burning. • When mouting with screw, use M3 mounting screw with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 0.27 to 0.29 N·m {28 to 30 gf}. Exceeding the specified torque may result in deterioration of the sealing or damage. • Secure the posts by thermal caulking or by pressing into an attached device. When pressed into an attached device, provide guides on the opposite ends of the posts to ensure that they do not fall out or rattle. ●Operating Body • Use an operating body with low frictional resistance and of a shape that will not interfere with the sealing rubber, otherwise the plunger may be damaged or the sealing may deteriorate. ●Handling • Do not handle the Switch in a way that may cause damage to the sealing rubber. • When handling the Switch, ensure that pressure is not applied to the posts in the directions shown in the following diagram. Also, ensure that uneven pressure or pressure in a direction other than the operating direction is not applied to the Actuator as shown in the following diagram. Otherwise, the post, Actuator, or Switch may be damaged, or the durability may be reduced. ●Using Micro Loads • Even when using micro load models within the operating range shown below, if inrush/surge current occurs, it may increase the contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company 6 Contact: www.omron.com/ecb Cat. No. B117-E1-04 1014(0207)(O)