Power Transformer Chassis Mount: Quick Pack FD6-36 Description: The FD6-36 Quick Pack small power transformer offers a significant reduction in size and weight over a standard transformer. This transformer can be used for a wide variety of applications. It is bobbin wound for reduced size and small operating space. Electrical Specifications (@25C): Maximum Power: 30.0VA Input Voltage: Series: 230VAC@50/60Hz Parallel: 115VAC@50/60Hz Output Voltage: [email protected] Hipot: 2500VAC primary to secondary; 1500VAC windings to core. Construction: Split bobbin non concentric winding eliminates costly electrostatic shielding. Termination is suitable for quick connects or soldering. Built with UL Class B Insulation System. Safety: E UL: File E53148, UL 5085-1 and 2 (formerly UL 506), General Purpose. 10 8 6 Dimensions: A B C D E F G 1.937 2.812 3.250 1.687 2.312 .187 Dia 1.062 A Notes: 1. Units: inches. 2. Terminal size: .187” X 0.021”. 3. Weight: 1.10 lbs C Schematic: 1 6 2 3 4 5 8 1 2 4 F 10 D G 5 Input (115V): Input 1 & 2 Connect 1&4, 2&5 Input (230V): Input 1 & 5 Connect 2&4 Output: 6 & 10 B RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative.. * Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the most current version. Web: www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 Publish Date: December 4, 2013