Downloads for Chassis Mount Leaded World Series™ Power Transformers (VPL28-180)

P OWER TRANS FOR MER
Chassis Mount : International Series
VPL28-180
Electrical Specifications (@25C)
1. Maximum Power: 5.0VA
2. Input Voltage – Series: 230VAC @ 50/60Hz, Parallel: 115VAC@ 50/60Hz
1
2
3. Output Voltage – Series : 28.0V CT@ 0.180A, Parallel : 14.0V @ 0.360A
4. Voltage Regulation: 20% TYP @ full load to no load
5. Hipot: 3500VAC between primary to secondary and windings to core.
Construction:
BRN
BLU
BLK
WHT
Dual winding construction with an insulated shroud, both made of a high temperature
material that exceeds UL flammability requirements. Shrouds are provided over the
connections of the leads to the windings on both primary and secondary coils. Devices are
designed with a minimum of 6mm creepage distance between the primary and secondary
and are manufactured with a Class B (130°C) insulation system.
E
Agency Files:
GRY
YEL
Dimensions:
Units: In inches
A
B
C
D
E
F
1.437
2.375
1.437
2.00
8.00
0.187
VIO
RED
A
UL File: E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3
cUL: File E65390, For Canadian Use (CSA 22.2, No.66.1-06 and No.66.3-06)
TUV Certificate No.: R72103639, EN60950, Information Technology
B
D
Weight: 0.4 lbs.
C
3
Connections :
F
Input: Series – BLK to BLU, Jumper WHT to BRN
Parallel – BLK to BLU, Jumper BLK to BRN and WHT to BLU
Output: Series – RED to GRY, Jumper YEL to VIO
Parallel – RED to GRY, Jumper RED to VIO and YEL to GRY
BLK
RED
WHT
BRN
YEL
VIO
BLU
GRY
RoHS Compliance: As of manufacturing date February 2005, all standard products meet the
requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
1
Inherently limited. No fusing required. Class 3.
2
Inherently limited. No fusing required. Class 2 not wet, Class 3 wet.
3
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
SCHEMATIC
Publish Date: December 4, 2013