MA-COM AT

2.25 Volt Voltage Variable Absorptive Attenuator
42 dB, 1.8 - 2.5 GHz
Features
•
•
•
•
•
AT-119
V9
Functional Schematic
Single Positive Voltage Control: 0 to +2.25 Volts
42 dB Typical Attenuation Range at 2.4 GHz
Low DC Power Consumption
SOT-25 Plastic Package
Tape and Reel Packaging Available
5
VCC
4
VCTL
Description
M/A-COM’s AT-119 is a GaAs MMIC voltage
variable absorptive attenuator in a low cost, SOT-25
five-lead, surface mount plastic package. M/A-COM
fabricates the AT-119 with a proven monolithic GaAs
0.5 micron gate process that features full chip
passivation for performance and reliability.
1
RF
Applications
Package
AT-119
SOT-25 Plastic Package
AT-119TR-3000
3000 piece reel
AT-119SMB
Sample Test Board
(Includes 5 Samples)
Pin
Description
RF
RF (input / output)
2
GND
Ground
3
RF
RF (input / output)
4
VCTL
Control Voltage
5
VCC
DC Supply Voltage
TA = +25°C (unless otherwise specified)
2.
3.
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
Function
1
Absolute Maximum Ratings 2,3
1. Reference Application Note M513 for reel size information.
1
100pF
Pin Configuration
Ordering Information 1
Part Number
3
RF
100pF
The AT-119 is ideally suited for applications that
require fine tuning, linear attenuation with voltage,
and very low power consumption.
Typical applications for the AT-119 include
automatic gain control circuits in satellite radio
receivers and other wireless receivers.
2
GND
Parameter
Absolute Maximum
Input Power
+21 dBm
Supply Voltage VCC
-1V ≤ VCC ≤ +8 V
Control Voltage VCTL
-1V ≤ VCTL ≤ VCC +0.5 V
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
Exceeding any one or combination of these limits may cause
permanent damage to this device.
M/A-COM does not recommend sustained operation near
these survivability limits.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
2.25 Volt Voltage Variable Absorptive Attenuator
42 dB, 1.8 - 2.5 GHz
AT-119
V9
Electrical Specifications: TA = 25°C, Frequency = 2.4 GHz, VCC = 3.3 V, Z0 = 50 Ω
Parameter
Test Conditions 4,5
Units
Min.
Typ.
Max.
Insertion Loss
VCTL = 2.25 V
dB
—
2.4
3.2
Maximum Attenuation
VCTL = 0.5 V
dB
37
42
—
Attenuation Slope
0.75 V < VCTL < 1.75 V
dB/V
24
—
—
Return Loss
0.0 V < VCTL < 0.75 V
0.75 V < VCTL < 1.75 V
1.75 V < VCTL < 2.25 V
dB
dB
dB
—
—
—
6
10
14
—
—
—
Input Power for 1dB Change in Attenuation
0.75 V < VCTL < 2.25 V
dBm
—
10
—
Input 3rd Order Intercept Point
0.75 V < VCTL < 2.25 V
dBm
—
15
—
Switching Speed
50% VCTL to 10% / 90% RF
nS
—
100
—
Transients
VCTL = 3 V, In-Band
mV
—
10
—
4.
5.
External DC blocking capacitors are required on all RF ports.
VCC = +3.3 V @ 50 µA typical. VCTL = 0 V to +2.25 V @ 50 µA typical.
Application Schematic
Handling Procedures
VCC
V control
Static Sensitivity
100 pF
RF IN/
OUT
Please observe the following precautions to avoid
damage:
220 pF
100 pF
RF IN/
OUT
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
15 pF
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
2.25 Volt Voltage Variable Absorptive Attenuator
42 dB, 1.8 - 2.5 GHz
AT-119
V9
Typical Performance Curves
Insertion Loss vs. Frequency @ 2.25 V Control
Voltage
Attenuation vs. Control Voltage @ +25°C
0
4.0
3.5
10
3.0
20
2.5
30
2.0
1.5
40
+25°C
-40°C
+85°C
1.0
50
0.5
0.0
0.5
1.0
1.5
2.0
2.5
1.8 GHz
2.1 GHz
2.4 GHz
3.0
60
3.0
2.5
2.0
1.5
1.0
0.5
0.0
Control Voltage (V)
Frequency (GHz)
Attenuation vs. Frequency @ 0.0 V Control Voltage
Typical Device Variation, 2.4 GHz
0
0
10
10
20
20
30
30
40
40
50
50
60
+25°C
-40°C
+85°C
60
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0.5
1.0
Control Voltage (V)
1.5
2.0
2.5
3.0
Frequency (GHz)
Return Loss vs. Control Voltage
Insertion Loss Delta Normalized to +25°C (-40°C)
8
0
6
5
4
10
2
0
15
-2
20
1.8 GHz
2.1 GHz
2.4 GHz
1.8 GHz
2.1 GHz
2.4 Ghz
-4
25
-6
-8
30
2.0
1.5
1.0
0.5
0.0
Control Voltage (V)
3
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
3.0
2.5
2.0
1.5
1.0
0.5
0.0
Control Voltage (V)
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
2.25 Volt Voltage Variable Absorptive Attenuator
42 dB, 1.8 - 2.5 GHz
AT-119
V9
Typical Performance Curves
Insertion Loss Delta Normalized to +25°C (+85°C)
Input IP3 vs. Control Voltage @ +25°C
8
40
6
35
4
30
2
25
0
20
-2
15
1.8 GHz
2.1 GHz
2.4 GHz
-4
10
5
-6
0
-8
3.0
2.5
2.0
1.5
1.0
0.5
3.0
0.0
2.5
2.0
1.5
1.0
0.5
0.0
Control Voltage (V)
Control Voltage (V)
Input Power for 1 dB Change in Attenuation
30
Input IP3 vs. Control Voltage over Temperature
40
IIP3 @ +25C
IIP3 @ +85C
IIP3 @ -40C
35
25
30
20
25
15
20
15
10
10
5
0
3.0
1.8 GHz
2.4 GHz
2.5
2.0
1.5
5
1.0
0.5
0.0
Control Voltage (V)
0
3.0
2.5
2.0
1.5
1.0
0.5
0.0
Control Voltage (V)
SOT-25
4
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.