WKP Series Datasheet

WKP Series
www.vishay.com
Vishay Draloric
AC Line Rated Ceramic Disc Capacitors
Class X1, 760 VAC, Class Y1, 500 VAC
FEATURES
• Complying with IEC 60384-14 4th edition
• High reliability
• Wide range of different leadstyles
• Singlelayer AC disc safety capacitors
• Material categorization: for definitions of
compliance please see www.vishay.com/doc?99912
APPLICATIONS
• X1, Y1 according to IEC 60384-14.4
• Across-the-line
• Line-by-pass
QUICK REFERENCE DATA
• Antenna coupling
DESCRIPTION
VALUE
Ceramic Class
Ceramic Dielectric
Voltage (VAC)
1
DESIGN
2
N750
N750
Y5S,
Y5T,
Y5U
Y5S,
Y5T,
Y5U
The capacitors consist of ceramic disc both sides of which
are silver plated. Connection leads are made of tinned
copper having diameters of 0.6 mm or 0.8 mm.
500
760
500
760
The capacitors may be supplied with straight or kinked
leads having a lead spacing of 10.0 mm or 12.5 mm.
Min. Capacitance (pF)
33
47
Max. Capacitance (pF)
33
4700
Mounting
Radial
Coating is made of blue colored flame retardant epoxy resin
in accordance with UL 94 V-0.
CAPACITANCE RANGE
MARKING
33 pF to 4.7 nF
Marking indicates series, AC rating, capacitance, tolerance
code, and approvals.
TOLERANCE ON CAPACITANCE
± 10 %, ± 20 %
OPERATING TEMPERATURE RANGE
-40 °C to +125 °C
TEMPERATURE CHARACTERISTICS
Class 1
N750 (U2J)
Class 2
Y5S, Y5T, Y5U
SECTIONAL SPECIFICATIONS
RATED VOLTAGE
• X1:
760 VAC, 50 Hz (IEC 60384-14.4)
760 VAC, 50 Hz / 60 Hz (US/UL/CSA 60384-14)
• Y1:
500 VAC, 50 Hz (IEC 60384-14.4)
500 VAC, 50 Hz / 60 Hz (US/UL/CSA 60384-14)
TEST VOLTAGE
Climatic category (according to EN 60058-1)
• 4000 VAC, 50 Hz, 2 s
Class 1
40/125/21
• 4000 VAC, 50 Hz, 60 s Random sampling test (destructive)
Class 2
40/125/21
• 4000 VAC, 50 Hz, 60 s Voltage proof of coating (destructive)
Component test (100 %)
APPROVALS
INSULATION RESISTANCE AT 500 VDC
IEC 60384-14.4
UL 60384-14.1
CSA E60384-1:03 2nd edition, CSA E60384-14:09 2nd edition
10 000 M (60 s)
Revision: 19-Feb-16
DISSIPATION FACTOR
Class 1:
max. 0.5 % (1 kHz)
Class 2:
max. 2.5 % (1 kHz)
Document Number: 22206
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
WKP Series
www.vishay.com
Vishay Draloric
DIMENSIONS in millimeters
Smax.
3.0 max.
Dmax.
V
F
30 - 3
or 10 ± 1
Ø d ± 0.05
TECHNICAL DATA
CAPACITANCE (2)
C (pF)
CAPACITANCE
TOLERANCE
BODY
DIAMETER
DMAX. (mm)
BODY
THICKNESS
SMAX. (mm)
LEAD
SPACING (1)
F (mm)
± 1 mm
LEAD
DIAMETER (1)
d (mm)
± 0.05 mm
WIDTH (1)
V (mm)
± 0.5 mm
± 10 %,
± 20 %
8.0
6.0
12.5
0.6
1.9
PART NUMBER
MISSING DIGITS
SEE ORDERING
CODE BELOW
N750 (U2J)
33
WKP330#CP###KR
Y5S (2C3)
47
WKP470#CP###KR
± 10 %,
68
8.0
6.0
12.5
0.6
2.3
WKP680#CP###KR
± 20 %
100
WKP101#CP###KR
Y5T (2D3)
150
WKP151#CP###KR
± 10 %,
8.0
6.0
12.5
0.6
2.3
± 20 %
220
WKP221#CP###KR
Y5U (2E3)
330
WKP331#CP###KR
8.0
470
0.6
2.5
WKP471#CP###KR
680
9.0
WKP681#CP###KR
1000
10.0
WKP102#CP###KR
± 10 %,
6.0
12.5
1500
12.0
WKP152#CP###KR
± 20 %
2200
13.0
WKP222#CP###KR
0.8
2.7
3300
15.0
WKP332#CP###KR
3900
16.0
WKP392#CP###KR
4700
18.0
WKP472#CP###KR
Notes
(1) Standard lead configuration, other lead spacing and diameter available on request
(2) Capacitance values from 1 nF to 4.7 nF: the alternative usage of smaller VKP series is recommended for new application.
ORDERING CODE
7th digit
10th to 12th digit
WKP
#
###
Example
Series
Capacitance tolerance
Lead configuration
222
M
Capacitance
Tolerance code
value
± 10 % = K, ± 20 % = M
see “General Information”
CP
ED0
Lead
Voltage code
configuration
K
Internal code
R
RoHS
compliant
MARKING
WKP
760~X1
500~Y1
33p M
WKP 33 pF to 1.5 nF
Revision: 19-Feb-16
IEC 384-14/2
760 500 250~
X1 Y1
WKP 2n2 M
WKP 2.2 nF to 4.7 nF
Document Number: 22206
2
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
WKP Series
www.vishay.com
Vishay Draloric
APPROVALS
IEC 60384-14.4 - Safety tests
This approval together with CB test certificate substitutes all national approvals.
CB Certificate
Y1-capacitor: CB test certificate:
US-26549-UL
33 pF to 4.7 nF
500 VAC
X1-capacitor: CB test certificate:
US-26549-UL
33 pF to 4.7 nF
760 VAC
Minimum thickness of insulation: 0.4 mm
VDE
Y1-capacitor: VDE marks approval:
136493
33 pF to 4.7 nF
500 VAC
X1-capacitor: VDE marks approval:
136493
33 pF to 4.7 nF
760 VAC
DIN EN 60384-14 VDE 0565-1-1:2006-04 - Safety tests
Minimum thickness of insulation: 0.4 mm
Underwriters Laboratories Inc. / Canadian Standards Association
Y1-capacitor: UL-test certificate:
E183844
33 pF to 4.7 nF
500 VAC
X1-capacitor: UL-test certificate:
E183844
33 pF to 4.7 nF
760 VAC
UL 60384-14.1, CSA E60384-1:03 2nd edition, CSA E60384-14:09 2nd edition
Across-the-line, antenna-coupling and line-by-pass component
Minimum thickness of insulation: 0.4 mm
5000
IMPEDANCE VS. FREQUENCY (typical)
Z (Ω)
I (μA)
LEAKAGE CURRENT VS. VOLTAGE (typical)
4000
10
4.7 nF
1
3000
2000
2.2 nF
4700 pF
3900 pF
3300 pF
2200 pF
1500 pF
1000 pF
680 pF
470 pF
330 pF
220 pF
150 pF
100 pF
68 pF
3.3 nF
0.1
1.0 nF
1000
470 pF
0
0.01
0
500
1000 1500 2000 2500 3000 3500 4000
1
10
100
UR (V~)
1000
f (MHz)
RELATED DOCUMENTS
General Information
www.vishay.com/doc?22001
CB Test Certificate
www.vishay.com/doc?22214
VDE Marks Approval
www.vishay.com/doc?22216
UL Test Certificate
www.vishay.com/doc?22215
Revision: 19-Feb-16
Document Number: 22206
3
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000