BAT54, BAT54A, BAT54C, BAT54S Datasheet

BAT54, BAT54A, BAT54C, BAT54S
www.vishay.com
Vishay Semiconductors
Small Signal Schottky Diodes, Single and Dual
FEATURES
• These diodes feature very low turn-on voltage
and fast switching
• These devices are protected by a PN junction
guard ring against excessive voltage, such as
electrostatic discharges
• AEC-Q101 qualified available
BAT54
• Base P/N-E3 - RoHS-compliant, commercial grade
BAT54A
• Base P/N-HE3 - RoHS-compliant, AEC-Q101 qualified
3
3
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
Top View
1
2
1
MECHANICAL DATA
2
Case: SOT-23
BAT54C
BAT54S
3
3
Weight: approx. 8.8 mg
Packaging codes/options:
18/10K per 13" reel (8 mm tape), 10K/box
Top View
08/3K per 7" reel (8 mm tape), 15K/box
1
2
2
1
PARTS TABLE
PART
ORDERING CODE
BAT54
BAT54A
BAT54C
BAT54S
INTERNAL CONSTRUCTION
TYPE MARKING
Single diode
L4
Dual diodes common anode
L42
Dual diodes common cathode
L43
Dual diodes serial
L44
BAT54-E3-08 or BAT54-E3-18
BAT54-HE3-08 or BAT54-HE3-18
BAT54A-E3-08 or BAT54A-E3-18
BAT54A-HE3-08 or BAT54A-HE3-18
BAT54C-E3-08 or BAT54C-E3-18
BAT54C-HE3-08 or BAT54C-HE3-18
REMARKS
Tape and reel
BAT54S-E3-08 or BAT54S-E3-18
BAT54S-HE3-08 or BAT54S-HE3-18
ABSOLUTE MAXIMUM RATINGS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
SYMBOL
VALUE
Repetitive peak reverse voltage
TEST CONDITION
VRRM
30
V
Forward continuous current (1)
IF
200
mA
IFRM
300
mA
IFSM
600
mA
Ptot
230
mW
Repetitive peak forward current (1)
Surge forward current (1)
tp < 1 s
Power dissipation
UNIT
Note
(1) Device on fiberglass substrate, see layout on next page
THERMAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
Thermal resistance junction to ambient air
Junction temperature
TEST CONDITION
SYMBOL
VALUE
UNIT
Device on fiberglass substrate,
see layout on next page
RthJA
430
K/W
Tj
125
°C
Storage temperature range
Tstg
-65 to +150
°C
Operating temperature range
Top
-55 to +125
°C
Rev. 1.9, 16-Mar-16
Document Number: 85508
1
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
BAT54, BAT54A, BAT54C, BAT54S
www.vishay.com
Vishay Semiconductors
ELECTRICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
TEST CONDITION
SYMBOL
MIN.
Reserve breakdown voltage
IR = 100 μA (pulsed)
V(BR)
30
Leakage current
Forward voltage
Diode capacitance
Reserve recovery time
TYP.
MAX.
UNIT
V
Pulsed test tp < 300 μs,  <2 % at VR = 25 V
IR
2
μA
IF = 0.1 mA, tp < 300 μs,  < 2 %
VF
240
mV
IF = 1 mA, tp < 300 μs,  < 2 %
VF
320
mV
IF = 10 mA, tp < 300 μs,  < 2 %
VF
400
mV
IF = 30 mA, tp < 300 μs,  < 2 %
VF
500
mV
IF = 100 mA, tp < 300 μs,  < 2 %
VF
800
mV
VR = 1 V, f = 1 MHz
CD
10
pF
IF = 10 mA to IR = 10 mA,
iR = 1 mA, RL = 100 
trr
5
ns
LAYOUT FOR RthJA TEST
Thickness:
Fiberglas 15 mm (0.059")
Copper leads 0.3 mm (0.012")
7.5 (0.3)
3 (0.12)
1 (0.4)
2 (0.8)
1 (0.4)
12 (0.47)
2 (0.8)
0.8 (0.03)
15 (0.59)
5 (0.2)
1.5 (0.06)
5.1 (0.2)
17451
TYPICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
14
100
T j = 125 °C
- 40 °C
10
1
25 °C
0.1
0.01
0
18867
12
C D - Typical Capacitance (pF)
I F - Forward Current (mA)
1000
10
8
6
4
2
0
0.2
1.2
0.4 0.6 0.8
1
VF - Forward Voltage (V)
0
1.4
Fig. 1 - Typical Forward Voltage Forward Current vs.
Various Temperatures
18868
4
12
16
20
24
8
VR - Reverse Voltage (V)
28
Fig. 2 - Diode Capacitance vs. Reverse Voltage VR
Rev. 1.9, 16-Mar-16
Document Number: 85508
2
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
BAT54, BAT54A, BAT54C, BAT54S
www.vishay.com
Vishay Semiconductors
1000
I R - Reverse Current (µA)
T j = 125 °C
100
100 °C
75 °C
10
50 °C
1
25 °C
0.1
0.01
0
18869
5
10
15
20
25
VR - Reverse Voltage (V)
30
Fig. 3 - Typical Variation of Reverse Current
vs. Various Temperatures
PACKAGE DIMENSIONS in millimeters (inches): SOT-23
1.15 (0.045)
o8
°
0.2 (0.008)
0.098 (0.004)
0.175 (0.007)
0.1 (0.004) max.
0.550 ref. (0.022 ref.)
0.9 (0.035)
3.1 (0.122)
2.8 (0.110)
0.45 (0.018)
0.35 (0.014)
0.35 (0.014)
0° t
0.5 (0.020)
0.45 (0.018)
0.3 (0.012)
2.6 (0.102)
2.35 (0.093)
Foot print recommendation:
1 (0.039)
0.9 (0.035)
Document no.: 6.541-5014.01-4
Rev. 8 - Date: 23.Sept.2009
17418
0.9 (0.035)
0.7 (0.028)
2 (0.079)
1.43 (0.056)
1.20 (0.047)
0.45 (0.018)
0.35 (0.014)
1 (0.039)
0.9 (0.035)
0.95 (0.037)
0.95 (0.037)
Rev. 1.9, 16-Mar-16
Document Number: 85508
3
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000