PMBus DC/DC Converters with Power System Management

PMBus DC/DC Converters
with Power System Management
VIN
VOUT1
L
O
A
D
LTC3883
DC/DC Controller
VIN
VOUT2
LTC3880
L
O
A
D
VIN
DC/DC Controller
VOUT3
L
O
A
D
VIN
VOUT4
rPlay
LTpowe
L
O
A
D
For Prototyping and Debug
FREE Download
www.linear.com/LTpowerPlay
LTM4676
µModule® Regulator
USB
DC1613
PMBus Controller
Features
Power Supply Configuration
Sequence, Trim Margin and Supervise
Monitor Telemetry
Manage Faults and Create Fault Logs
LTpowerPlay™ GUI Support
PWM Control Mode
Integrated Power Stage
Accurate Current Monitoring
External Temperature Monitoring
Input Voltage Sense
Input Current Sense
Current Sense Calibration
Time Based Sequencing
Programmable Output Ramp Rate
Trim and Margin Accuracy
Fault Logging to Internal EEPROM
Autonomous Operation — “Set and Forget”
PMBus Compliant Command Set
PMBus
VOUT5
L
O
A
D
To other PMBus Power System Managers and DC/DC Converters
LTC®3880
Dual Output DC/DC
Controller
Dual
ü
ü
ü
ü
Current
LTC3883
Single Output DC/DC
Controller
Single
ü
ü
ü
ü
Current
ü
ü
ü
Inferred
ü
ü
ü
Direct
ü
ü
ü
0.5%
ü
ü
ü
ü
ü
0.5%
ü
ü
ü
L, LT, LTC, LTM, Linear Technology, the Linear logo and µModule
are registered trademarks and LTpowerPlay is a trademark of
Linear Technology Corporation. All other trademarks are the
property of their respective owners.
LTM®4676
Dual Output µModule
Regulator
Dual
ü
ü
ü
ü
Current
ü
ü
Optional
ü
Inferred
Factory Trimmed
ü
ü
1%
ü
ü
ü
Complete Power System Management Family
DC/DC Converters
with Power System Management
Power System Managers
Power Supply Channels
LTC2977
LTC2978(A)
LTC2974
LTC2975**
LTC3880
LTC3883
2
8
8
4
4
2
1
2
ü
ü
ü
ü
ü
ü
ü
Overview
Sequence
Trim and Margin
ü
ü
ü
ü
ü
ü
ü
ü
Supervise
ü
ü
ü
ü
ü
ü
ü
ü
Monitor Telemetry
ü
ü
ü
ü
ü
ü
ü
ü
Manage Faults
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
Create Fault Logs
Point-of-Load Buck Controller
Power
LTpowerPlay GUI Support
Sequencing
ü
ü
ü
ü
ü
ü
Output Channels
–
–
–
–
–
2
1
2
Output Voltage Range
–
–
–
–
–
0.5V to 5.5V
0.5V to 5.5V
0.5V to 5.4V
PWM Control Mode
–
–
–
–
–
Current
Current
Current
15V
15V
15V
15V
15V
24V
24V
26.5V
Time Based Sequencing
ü
ü
ü
ü
ü
ü
ü
Shared Timebase (SHARE_CLK)
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
0.25%
0.25%
Integrated Power Stage
Maximum Input Voltage
ü
Cascade Sequencing
Interfaces to Tracking DC/DC Converters
ü
Servo
Programmable Output Ramp Rate
Trim Accuracy*
Supervision
0.25%
0.25%
ü
ü
ü
0.5%
0.5%
1%
ü
ü
ü
ü
ü
ü
ü
ü
Margin Accuracy*
0.5%
0.25%
0.25%
0.25%
0.25%
0.5%
0.5%
1%
Worst Case Voltage Supervisor Accuracy*
ü
ü
ü
ü
ü
ü
ü
ü
0.5%
1.5%
1.5%
1.5%
1.5%
2.0%
2.0%
2.0%
Typical Analog OV Response Time*
–
–
–
–
–
100ns
100ns
100ns
Typical OV Fault Off-Time*
–
12µs
12µs
12µs
12µs
30µs
30µs
30µs
Input Voltage Comparator
ü
ü
ü
ü
ü
ü
ü
ü
Output Current Supervision
ü
ü
ü
ü
ü
ü
1 Internal
4 External
4 External
1 Int + 2 Ext
1 Int + 1
2 Int + 1 Ext
2
Temperature Supervision
Monitoring
0.5%
Margin High/Low
Output Voltage Supervision
1 Internal
1 Internal
Differential Output Voltage Sense Channels
2
8
8
4
4
2
1
Output Current Sense Channels
2
4†
4†
4
4
2
1
2
External Temperature Channels
–
–
–
4
4
2
1
1 Opt
Input Voltage Sense
ü
ü
ü
ü
ü
ü
ü
ü
Input Current Sense
–
–
–
–
Direct
Inferred
Direct
Inferred
ü
ü
ü
ü
Factory Trimmed
Input Power and Energy
ü
Output Power
ü
ü
Current Sense Calibration
Faults
Duty Cycle
ü
ü
ü
Fault Logging to Internal EEPROM
ü
ü
ü
ü
ü
ü
ü
Fault Sharing
ü
ü
ü
ü
ü
ü
ü
Autonomous Retry on Fault
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
Disable DC/DC Converter on Fault
ü
Disable Intermediate Bus Converter on Fault
Autonomous Operation — “Set and Forget”
Miscellaneous
LTM®4676
LTC2970
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
400kHz
400kHz
400kHz
400kHz
400kHz
100kHz
100kHz
100kHz
PMBus Compliant Command Set
ü
ü
ü
ü
ü
ü
ü
Command Plus Command Set
ü
6mm × 6mm
QFN
5mm × 5mm
QFN
16mm × 16mm
BGA
Power Good Support
Max I2C w/o Clock Stretching
Package
4mm × 5mm
QFN
9mm × 9mm
QFN
ü
9mm × 9mm
QFN
9mm × 9mm
QFN
9mm × 9mm
QFN
For the latest information, see http://www.linear.com/products/Power_System_Management
* Consult data sheet(s) for detailed specifications.
† Not temperature compensated. Available on odd channels only. All other channel features are disabled.
**Future product.
www.linear.com/pmbusconverters n 1-800-4-LINEAR
0413