Family data sheet

Product family datasheet
Baby SharXS HTI
Metal halide lamps, double-ended
__
Product benefits
_ High average luminance (30…50 kcd/cm2)
Product features
_ Color temperature: approx. 6,000 K (Daylight)
_ Hot restart capability
_ AC current
_ Average life: 500…3,000 h (depending on type)
_ Good color rendering index: R > 80 to > 85
a
June 23, 2016, 12:05:34
Baby SharXS HTI
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 4
Product family datasheet
Product line drawing
__
June 23, 2016, 12:05:34
Baby SharXS HTI
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 4
Product family datasheet
Technical data
Electrical data
Photometrical data
Dimensions & weight
Temperat
ures &
operating
condition
s
Lifespan
Additional
product data
Product description
Nominal
voltage
Ignition voltage
Nominal
current
Color
temperature
Color
rendering index
Ra
Diameter
Length
Light
center
length
(LCL)
Max.
permitted pinch
temp.
Lifespan
Base
(standard
designation)
Baby SharXS HTI 250 W/D5/80
75.0 V
2.0 / 20 kVp 1)
3.30 A
8000 K
› 85
16.0 mm
93.0 mm
35.0 mm
450 °C
3000 h
SFc10-4
Baby SharXS HTI 300 W/D5/57
75.0 V
4.5 / 20 kVp
4.30 A
5700 K
80
16.0 mm
93.0 mm
35.0 mm
450 °C
3000 h
SFc10-4
Baby SharXS HTI 300 W/D5/65
95.0 V
4.5 / 20 kVp
3.60 A
6500 K
85
16.0 mm
93.0 mm
35.0 mm
450 °C
750 h
SFc10-4
Baby SharXS HTI 575 W/D5/56
93.0 V
4.5 / 20 kVp
7.20 A
5600 K
85
16.0 mm
93.0 mm
35.0 mm
450 °C
500 h
SFc11-4
Capabilities
Certificates
&
standards
Product description
Burning position
EEI –
Energy
Label
Baby SharXS HTI 250 W/D5/80
Any
C
Baby SharXS HTI 300 W/D5/57
Any
C
Baby SharXS HTI 300 W/D5/65
Any
C
Baby SharXS HTI 575 W/D5/56
Any
C
__
1) Cold
June 23, 2016, 12:05:34
Baby SharXS HTI
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 4
Product family datasheet
Safety advice
Because of their high luminance, UV radiation and high internal pressure during operation, Baby SharXS HTI lamps may only be
operated in enclosed lamp casings specially constructed for the purpose. Appropriate filters must ensure that UV radiation is
reduced to an acceptable level. Mercury is released if the lamp breaks. Special safety precautions must be taken. Information
on safety and handling is available on request or can be found in the leaflet included with the lamp or in the operating
instructions.
Application advice
For more detailed application information and graphics please see product datasheet.
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.