INTERSIL ZL2004ALNNT-01

ZL2004-01
February 18, 2009
Data Sheet
FN6847.0
Adaptive Digital DC-DC Controller with Current Sharing
Features
Description
Power Conversion
The ZL2004-01 is specialized version of the ZL2004
DC-DC controller that has been optimized for high
output accuracy within a given set of operating
conditions. The ZL2004-01 is otherwise identical to
the ZL2004 in features and functionality.
The
ZL2004-01 has been optimized for use with the
ZL1505 MOSFET driver and discrete MOSFETs.
•
•
•
•
•
•
•
•
The ZL2004-01 integrates a proprietary Digital-DC
communication bus for current sharing and inter device
communication. Adaptive algorithms improve light
load efficiency. All operating features can be
configured by simple pin-strap selection, resistor
selection or through the on-board serial port. The
PMBus™-compliant ZL2004-01 uses the SMBus™
serial interface for communication with other DigitalDC products or a host controller.
Efficient synchronous buck controller
± 0.2% VOUT set-point accuracy
8.0 V to 10.0 V input range
0.9 V to 1.1 V output range
Adaptive performance optimization algorithms
Fast load transient response
Active current sharing
DCR current sensing with digitally adjustable
current sense range
RoHS compliant (5 x 5 mm) QFN package
•
Power Management
•
•
•
•
•
•
•
•
Digital soft start/stop
Precision delay and ramp-up
Power good/enable
Voltage tracking, sequencing and margining
Voltage/current/temperature monitoring
SMBus communication (PMBus compliant)
Output voltage and current protection
Internal non-volatile memory (NVM)
Applications
•
•
•
EN PG
V (0,1)
VMON
MGN
SYNC
SS
FC
ILIM CFG
Servers / storage equipment
Telecom / datacom equipment
Power supplies (memory, DSP, ASIC, FPGA)
FLEX
LDO
POWER
MANAGEMENT
DDC
SCL
SDA
SALRT
V25 VR VDD
LEVEL
SHIFTER
NONVOLATILE
MEMORY
PWM
CONTROLLER
I2 C
MONITOR
ADC
SA (0,1)
VSEN+/VTRK
XTEMP
CURRENT
SENSE
PWMH
PWML
ISENA
ISENB
TEMP
SENSOR
SGND DGND
Figure 1. Block Diagram
1
1-888-INTERSIL or 1-888-468-3774|Intersil (and design) is a registered trademark of Intersil Americas Inc.
Copyright © Intersil Americas Inc. 2009. All Rights Reserved
All other trademarks mentioned are the property of their respective owners
ZL2004-01
1. Electrical Characteristics
Table 1. Absolute Maximum Ratings
Operating beyond these limits may cause permanent damage to the device. Functional operation beyond the
Recommended Operating Conditions is not implied. Voltage measured with respect to SGND.
Parameter
DC supply voltage
Logic I/O voltage
Analog input voltages
MOSFET drive reference
Logic reference
Ground voltage differential
(VDGND-VSGND)
Junction temperature
Storage temperature range
Lead temperature
(soldering, 10 s)
Pin(s)
Value
VDD
CFG, DDC, EN, FC, FLEX, ILIM,
MGN, PG, SA(0,1), SALRT, SCL,
SDA, SS,
SYNC, VMON, V(0,1)
-0.3 to 17
V
-0.3 to 6.5
V
VSEN+, VSEN-, VTRK, XTEMP
-0.3 to 6.5
V
ISENA, ISENB
VR
V25
-1.5 to 6.5
-0.3 to 6.5
-0.3 to 3
V
V
V
DGND, SGND
-0.3 to +0.3
V
–
–
-55 to 150
-55 to 150
o
–
300
o
Table 2. Recommended Operating Conditions and Thermal Information
Symbol
Parameter
Input Supply Voltage Range
VDD
Unit
o
C
C
C
Min
8.0
Typ
–
Max
10.0
Unit
V
Output Voltage Range
VOUT
0.9
1.0
1.1
V
Operating Frequency
FSW
–
400
–
kHz
Operating Ambient Temperature Range
TA
0
–
65
°C
Junction to Ambient Thermal Impedance1
QJA
–
35
–
°C/W
QJC
–
5
–
°C/W
2
Junction to Case Thermal Impedance
Notes:
1. ΘJA is measured in free air with the device mounted on a multi-layer FR4 test board and the exposed metal pad soldered to a
low impedance ground plane using multiple vias.
2. For ΘJC, the “case” temperature is measured at the center of the exposed metal pad
2
Data Sheet Revision 2/18/2009
www.intersil.com
ZL2004-01
Table 3. Electrical Specifications
VDD = 8.6 V, VOUT = 1.0 V, TA = 0°C to 65°C unless otherwise noted. Typical values are at TA = 25°C.
The following specifications describe the ZL2004-01 electrical specifications that differ from the ZL2004. Please refer
to the ZL2004 data sheet for the full operating specification limits for the remaining functions not described herein.
Parameter
Input and Supply Characteristics
IDD supply current at fSW = 400 kHz
IDDS shutdown current
VR reference output voltage
V25 reference output voltage
Output Characteristics
Output voltage adjustment range
Output voltage setpoint accuracy 1
Conditions
Min
Typ
Max
Unit
GH no load, GL no load,
MISC_CONFIG[7] = 1
–
16
30
mA
EN = 0 V No I2C/SMBus activity
VDD > 6 V, IVR < 50 mA
VR > 3 V, IV25 < 50 mA
–
4.5
2.25
2
5.2
2.5
5
5.5
2.75
mA
V
V
VIN > VOUT
VIN = 8.6V, VOUT = 1 V
TA = 0 °C to + 65 °C,
ILOAD = 0-40A
0.9
–
1.1
V
- 0.2
–
0.2
%
–
400
–
kHz
-5
–
5
%
2.85
–
16
V
Oscillator and Switching Characteristics
SYNC pin floating or NVM configured
Switching frequency 2
for 400kHz
Switching frequency set-point accuracy
Fault Protection Characteristics
UVLO threshold range
Configurable via I2C/SMBus
Notes:
1. VOUT set-point measured at the termination of the VSEN+ and VSEN- sense points.
2. The ZL2004-01 has been optimized for operation at 400 kHz only. Please consult the factory for requirements at other
operating frequencies.
3
Data Sheet Revision 2/18/2009
www.intersil.com
ZL2004-01
2. Ordering Information
4
Data Sheet Revision 2/18/2009
www.intersil.com
ZL2004-01
3. Revision History
Rev. #
Description
1.0
Data sheet initial release
1.1
Updated Ordering Information
Date
March 2008
May 2008
Assigned file number FN6847 to datasheet as this will be the first release with an
Intersil file number. Replaced header and footer with Intersil header and footer.
FN6847.0
Updated disclaimer information to read “Intersil and it’s subsidiaries including
Zilker Labs, Inc.” No changes to datasheet content
5
February 2009
Data Sheet Revision 2/18/2009
www.intersil.com
ZL2004-01
Zilker Labs, Inc.
4301 Westbank Drive
Building A-100
Austin, TX 78746
Tel: 512-382-8300
Fax: 512-382-8329
© 2008, Zilker Labs, Inc. All rights reserved. Zilker Labs, Digital-DC, and the Zilker Labs Logo are trademarks
of Zilker Labs, Inc. All other products or brand names mentioned herein are trademarks of their respective holders.
This document contains information on a product under development. Specifications are subject to change without notice. Pricing, specifications and availability are subject to change without notice. Please see www.zilkerlabs.com for updated information. This product is not intended for use in connection with any high-risk activity,
including without limitation, air travel, life critical medical operations, nuclear facilities or equipment, or the
like.
The reference designs contained in this document are for reference and example purposes only. THE REFERENCE DESIGNS ARE PROVIDED "AS IS" AND "WITH ALL FAULTS" AND INTERSIL CORPORATION
AND IT’S SUBSIDIARIES INCLUDING ZILKER LABS, INC. DISCLAIMS ALL WARRANTIES,
WHETHER EXPRESS OR IMPLIED. ZILKER LABS SHALL NOT BE LIABLE FOR ANY DAMAGES,
WHETHER DIRECT, INDIRECT, CONSEQUENTIAL (INCLUDING LOSS OF PROFITS), OR
OTHERWISE, RESULTING FROM THE REFERENCE DESIGNS OR ANY USE THEREOF. Any use of
such reference designs is at your own risk and you agree to indemnify Intersil Corporation and it’s subsidiaries
including Zilker Labs, Inc. for any damages resulting from such use.
6
Data Sheet Revision 2/18/2009
www.intersil.com