THERMAL MEASUREMENT SYSTEM iQ-200 TM FEATURES: TEMPERATURE MEASURE TEMPERATURE, VELOCITY & PRESSURE WITH ONE SYSTEM » 12 thermocouple ports supporting J, K, T and E types, with a range of -40 to 750oC. iQ-200™ provides the user with the capability to simultaneously or individually measure all of the required thermal parameters with one system. » 16 thermister ports (also used » iQ-200™ provides multiple channels of Temperature, Velocity and Pressure. VELOCITY » iQ-200™ eliminates the need for having multiple systems or additional software to synchronize data collection of different parameters. » iQ-200™ comes with the unique LabVIEWTM - based operating software, IQstage™, eliminates data collection errors induced because of measurement time lapses or transience associated with the use of multiple systems. » iQ-200™ provides a compact, portable and versatile system to minimize lab clutter and go where measurement is required. » for velocity measurement) with a range of -10 to 85oC. » 16 hot wire anemometer ports supporting ATS single sensor velocity measurement technology, (requiring no need to change sensors when measuring different velocity ranges). » Supports ATS unique, patented Candle Stick Sensor APPLICATION DOMAIN iQ-200™ is designed to be used wherever Temperature, Pressure and Velocity measurements are required, either simultaneously or individually. OVERALL DIMENSIONS (D x W x H) Some examples where iQ-200 » » » » » » TM is used: Heat sink design and selection PCB characterization Card rack (ATCA, PICMG, 1U, etc.) characterization Qualification testing in the environmental chamber,e.g., NEBS, Milspec, etc. Mockup testing Wind tunnel testing of cards, heatsinks, etc. Data Port Panel Data Port Panel Back Panel 43 cm x 34 cm x 12.6 cm (17” x 13.3” x 5”) NUMBER OF VELOCITY CHANNELS 16 FLOW RANGE 0 to 50 m/s (0 to 10,000 ft/min) NUMBER OF THERMOCOUPLES 12 (J, K, T, and E types) NUMBER OF PRESSURE SENSORS 4 (Differential) PRESSURE RANGE 0 to 0.15 psi SOFTWARE IQstageTM VOLTAGE INPUT 110V or 220V WEIGHT 7.5 kg (15 lbs.) For further technical information, please contact Advanced Thermal Solutions, Inc. at 1-781-769-2800 or www.qats.com ATS Candlestick Sensor » Standard range for velocity measurement is 0-6 m/s (1200 ft/min). With custom calibration, the range is 0-50 m/s (10,000 ft/min) – no need to change sensors PRESSURE » Four ports supporting differential or absolute pressure measurements with a range of 0-1,035Pa (0-0.15 psi) DATA ACQUISITION SOFTWARE - IQstageTM » IQstage™ manages incoming data from various sensors and provides a rich graphical presentation of the results » User-friendly LabVIEWTM - based IQstage™ is included with the system » Free Lifetime Tech Support 89-27 ACCESS ROAD, NORWOOD, MA 02062 USA | T: 781.769. 2800 F: 781.769.9979 | WWW.QATS.COM R2_0215