OPTOTRONIC®
OT 50/220-240/24
Constant Voltage LED Power supply for 24V LED - Modules
1. Technical Data
Nominal Voltage
Input Voltage
Line Current, nominal
Mains Frequency
Power Factor
Interface
IP Rating
220 – 240 Vac
220 – 240 Vdc
198 – 264 Vac
198 – 264 Vdc
0,35A
0 / 50 / 60 Hz
0,95 @ 230 Vac
None
IP 20
Max Out Power
50 Watt
Output Voltage
Efficiency
Ambient Temperature Ta
Max. Case Temperature at Tc
Max. Cable Length
Max load per circuit breaker B10
Max load per circuit breaker B16
24 Vdc (- 0,5V/+0,9V)
85% @ 230 Vac
-20°C to +45°C
+95°C
10m
12
19
2. Connection Schemes
3. Safety
Power supplies can be connected in parallel on the primary side, but not on the secondary side
®
The installation of two or more OPTOTRONIC OT 50/220-240/24 Power supplies with common “-“ or “+” wiring is forbidden.
OSRAM AG
www.osram.com
2012-12-12
AA420880055
Steinerne Furt 62, 86167 Augsburg, Germany
No. 1, North Industrial Road
528000 Foshan Guangdong, P.R. China
OPTOTRONIC®
OT 50/220-240/24
Constant Voltage LED Power supply for 24V LED - Modules
Wiring and Connection
•
•
•
•
•
Ensure that the LED module load is within the range of rated voltage, current and power supply
(see Technical data)
Maximum output cable length is limited by EMI and cross diameter
Use output cable sections adequate to the load demand
The luminaire manufacturer is responsible for providing the required clearances and creepage
distances and also for protection against electrical shock, especially for the line and load wires
Wire preparation:
Input
Mains Terminal
Output
LED Terminal
A=11.5 mm, B=6 mm
A=11.5 mm, B=6 mm
Solid and flexible
Solid and flexible
Wire cross section :
Wire cross section :
H05VV-F 2x1,5 mm2
H03VV-F2x0,50 mm2
Cable Clamp Reference
Cable Jacket Diameter:
Round: max 7mm
Earth Connection
•
OT 50/24 is a “Protection Class II” power supply, therefore ground connection is not required
Mounting and Environmental protection
•
•
The control gear is an independent type for luminaire integration
Maximum permissible ambient temperature must not be exceeded. Make sure there is adequate
space to avoid a build-up of heat. In critical installations the temperature at tc has to be controlled. Cfr
drawing below:
Bottom view
2 General Note
•
•
•
Power supplies must be installed by a qualified electrician
Disconnected from mains supplies before wiring work
For further information see also “OPTOTRONIC – Technical guide” at www.osram.com