1W SMD DC-DC Converter P1JS-Series ● ● ● ● ● ● SMD 8 lead package Up to 3000 VDC isolation MTBF > 3.5 Mio. h at 25 °C -40...105 °C operating temperature range Efficiency up to 81 % Continuous short circuit protection Model guide Input voltage range Type P1JS3R33R3S P1JS3R305S P1JS053R3S P1JS0505S P1JS0509S P1JS0512S P1JS0515S P1JS0524S P1JS123R3S P1JS1205S P1JS1209S P1JS1212S P1JS1215S P1JS1515S P1JS2405S P1JS2409S P1JS2415S P1JS2424S [VDC] Full load [mA] typ. No load [mA] typ. [VDC] min. [mA] max. [mA] Output ripple & noise (see note 4) [mVp-p] typ. 2.97..3.63 2.97..3.63 4.5..5.5 4.5..5.5 4.5..5.5 4.5..5.5 4.5..5.5 4.5..5.5 10.8..13.2 10.8..13.2 10.8..13.2 10.8..13.2 10.8..13.2 13.5..16.5 21.6..26.4 21.6..26.4 21.6..26.4 21.6..26.4 415 388 263 250 250 250 250 250 111 104 104 103 103 82 52 52 51 51 25 25 20 20 20 20 20 20 15 15 15 15 15 10 7 7 7 7 3.3 5.0 3.3 5.0 9.0 12.0 15.0 24.0 3.3 5.0 9.0 12.0 15.0 15.0 5.0 9.0 15.0 24.0 30 20 30 20 11 9 7 5 30 20 11 9 7 7 20 11 7 5 303 200 303 200 110 84 66 42 303 200 110 84 66 66 200 110 66 42 30 30 30 30 30 30 60 60 30 30 30 30 60 60 30 30 60 60 Input current Part designation structure Output power Series designation P1 1W J Output voltage Mounting technology S SMD Output current Input voltage Output voltage 3R3 05 12 15 24 3R3 05 09 12 15 24 3.3 V 5V 12 V 15V 24 V 3.3 V 5V 9V 12 V 15 V 24 V Output configuration S single Efficiency typ. Maximum capacitive load [%] 73 78 76 80 80 80 80 80 75 80 80 81 81 81 80 80 81 81 [µF] 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 Packing blank TR Tube Reel Specifications Input Voltage range Filter Reflected ripple current Input / output: Isolation voltage tested for 60 sec. @ leakage current < 1mA Isolation resistance @ 500 VDC Capacitance Output Output voltage drift @ 3.3V Vout models Output voltage drift @ all other models Output voltage tolerance Output voltage deviation at load change Temperature coefficient Short circuit protection General Switching frequency Reliability, MTBF (MIL-HDBK-217 @ 25 °C) Physical Package material Weight ± 10 % of nominal Capacitors 15 mAp-p, typ. 3 kVDC 109 Ω, min. 20 pF, typ. ± 1.5 % @ 1% Vin change ± 1.2 % @ 1% Vin change ± 5 % @ 70 % load, See output voltage tolerance diagram See output voltage tolerance diagram 0.03 % / °C, max., at full load Continuous, auto recovery 100 kHz, typ. 300 kHz, max. 3.5 Mio. hours Environmental Operating temperature (ambient) Storage temperature Derating Cooling Case temperature rise at full load Humidity EMC CISPR22 / EN55022 class B (Recommended circuit refer to Fig. 1) CISPR22 / EN55022 class B (Recommended circuit refer to Fig. 1) IEC/EN61000-4-2 contact ± 8 kV perf. criteria B CE EMI RE EMS -40 °C to +105 °C -55 °C to +125 °C See derating curve Free air convection 25 °C Up to 95 %, non-condensing ESD Absolute maximum ratings Vin 3.3 V types Vin 5 V types Vin 12 V types Vin 15 V types Vin 24 V types Manual soldering lead temperature Soldering temperature Moisture sensitivity level (MSL) -0.7 ~ 5 VDC, max. 1 s -0.7 ~ 9 VDC, max. 1 s -0.7 ~ 18 VDC, max. 1 s -0.7 ~ 21 VDC, max. 1 s -0.7 ~ 30 VDC, max. 1 s 300 °C max. 10 s max., 1.5 mm distance from body 217 °C for 60 s max., 245 °C peak IPC/JEDEC J-STD-020D.1 Epoxy resin (UL94-V0) 1.5 g, typ. Page 1 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W SMD DC-DC Converter P1JS-Series Input reflected ripple current measure circuit oscilloscope current probe + Vin 4.7µH Measure point 220 µF ESR <1 Ω at 100 kHz Load - Vin Figure 1 Recommended EMC / EMI circuit for Class B standard + Vin 6.8µH + Vout 4.7µF Cout - Vin Load - Vout Cout see to table at figure 3 Page 2 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W SMD DC-DC Converter P1JS-Series Note: 1. Operation under minimum load will not damage the converter, however they may not meet all specifications. 2. Max. capacitive load is tested at nominal input voltage and full load. 3. Unless otherwise noted, all specifications are measured at Ta 25 °C, humidity <75 %, nominal input voltage and rated output load. 4. Ripple and noise tested with „parallel cable“.method. 5. P1JS series is not usable for IGBT driver applications. Page 3 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W SMD DC-DC Converter P1JS-Series Application notes 1) Requirement on output load To ensure this module can operate efficiently and reliably during operation, the minimum output load must be higher than 10 % of the full load. If the actual output power is very small, please connect a resistor with proper resistance at the output end in parallel to increase the load, or use our company’s products with a lower rated output power. Operation with smaller load than minimum load will not damage the converter. However, they may not meet all specification listed, and that will reduce the life time of product. 2) Overload Protection Under normal operating conditions, the output circuit of these products has no protection against overload. The simplest method is to connect a self recovery fuse in series at the input end or add a circuit breaker to the circuit. 3) Output Voltage Regulation and Over-voltage Protection Circuit The simplest device for output voltage regulation, over voltage and over current protection is a linear voltage regulator with overheat protection that is connected to the input or output end in series. 4) Recommended circuit If you want to further decrease the input / output ripple, filter capacitors may be connected to the input and output ends of the DC/DC converter, see (Figure 3). It should also be noted that the capacitance of the capacitor must be proper. If the capacitance is too large, a startup problem might arise. It should also be noted that the capacitance of the capacitor must be proper. If the capacitance is too large, a startup problem might arise. For an safe and reliable operation of every model, the recommended capacitance of the capacitor refer to table below. Figure 3 + Vin + Vout Cin - Vin Cout - Vout Vin P1JS3R3xxS P1JS05xxS P1JS12xxS P1JS15xxS P1JS24xxS Cin 4.7 µF 4.7 µF 2.2 µF 2.2 µF 1 µF Vout P1JSxx3R3S P1JSxx05S P1JSxx09S P1JSxx12S P1JSxx15S P1JSxx24S Cout 10 µF 10 µF 4.7 µF 2.2 µF 1 µF 0.47 µF It’s not recommended to connect any external capacitor in the application field with less than 0.5 W output power! 5) The input and the output of the product are recommended to be connected to ceramic capacitor or electrolytic capacitor. Using tantalum capacitor may cause risk of failure 6) Not for parallel connection or plug and play (hot swap) application! Package dimensions Lead 1 2 3 4 5 6 7 8 - Vinput + Vinput No lead - Voutput + Voutput No lead No lead Not connected Notes: All dimensions are in mm General tolerances ±0.25 mm Pin tolerances ±0.1 mm Page 4 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W SMD DC-DC Converter P1JS-Series PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 10.14 f Page 5 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]