C505A-4RM, C505CA-2RM/4RM/LM, C505CA-4RC, Step ES-CA, CA

Errata Sheet
V 1.1, 2006-03
Device
C505A-4RM,
C505CA-2RM/4RM/LM,
C505CA-4RC
Marking/Step
Step ES-CA, CA
Package
P-MQFP-44, Bare Die
This Errata Sheet describes the deviations from the current user documentation.
The module oriented classification and numbering system uses an ascending sequence
over several derivatives, including already solved deviations. So gaps inside this
enumeration can occur.
Current Documentation
•
•
•
•
•
C505(C) User's Manual 08.97
C505A/C505CA Addendum to C505(C) User’s Manual 09.97
C505(A)/C505C(A) Data Sheet 12.02
C505CA-4RC Step BB (Bare Die) Data Sheet V1.3 12.00
Instruction Set Manual 05.98
Note: Devices marked with EES- or ES are engineering samples which may not be
completely tested in all functional and electrical characteristics, therefore they
should be used for evaluation only.
The specific test conditions for EES and ES are documented in a separate Status Sheet.
Contents
Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page
History List/Change Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Functional Deviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Deviations from Electrical- and Timing Specification. . . . . . . . . . . . . . . . . . . . . . . .6
Application Hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Errata Sheet, C505A-4RM/C505CA-2RM/C505CA-4RM/C505CA-LM/C505CA-4RC,
Step ES-CA, CA
1/7
V 1.1, 2006-03
Errata Sheet
History List/Change Summary
1
History List/Change Summary
(since last CPU Step ES-CA,CA, previous Errata Sheet V1.0)
Table 1
Functional Deviations
Functional
Deviation
Short Description
CAN.2
Unexpected Remote Frame Transmission (C505CA
only)
CAN.3
Description in User's Manual regarding the reception
of remote frames and the data length code (DLC) field
is incorrect (C505CA only)
CAN.4
Flowchart sequence in figure in User's Manual
regarding Micro-controller handling of the Last Message Object is partly incorrect (C505CA only)
CAN.5
Description in User's Manual section 6.4.5 regarding
the Configuration of the Bit Timing is partly incorrect
(C505CA only)
SWPD.1
Triggering of Software Power Down (SWPD) wake up
immediately after SWPD entry via external interrupt
on a frequent basis is not recommended.
Table 2
AC/DC Deviations
AC/DC
Deviation
Short Description
DC.4
Minimum limit of logic 0 input current IIL min is lower
Table 3
Application Hints
Application
Hint
Short Description
HINT.1
Content of VR2 register is incremented
Fixed
Change
in Step
Fixed
Change
in Step
Fixed Change
in Step
NEW
Errata Sheet, C505A-4RM/C505CA-2RM/C505CA-4RM/C505CA-LM/C505CA-4RC
Step ES-CA, CA
2/7
V 1.1, 2006-03
Errata Sheet
Functional Deviations
2
Functional Deviations
CAN.2: Unexpected Remote Frame Transmission (C505CA only)
The on-chip CAN module may send an unexpected remote frame with the identifier=0,
when a pending transmit request of a message object is disabled by software.
There are three possibilities to disable a pending transmit request of a message object
(n=1..14):
• Set CPUUPDn element
• Reset TXRQn element
• Reset MSGVALn element
Either of these actions will prevent further transmissions of message object n.
The symptom described above occurs when the CPU accesses CPUUPD, TXRQ or
MSGVAL, while the pending transmit request of the corresponding message object is
transferred to the CAN state machine (just before start of frame transmission). At this
particular time the transmit request is transferred to the CAN state machine before the
CPU prevents transmission. In this case the transmit request is still accepted from the
CAN state machine. However the transfer of the identifier, the data length code and the
data of the corresponding message object is prevented. Then the pre-charge values of
the internal ìhidden bufferî are transmitted instead, this causes a remote frame
transmission with identifier=0 (11 bit) and data length code=0.
This behavior occurs only when the transmit request of message object n is pending and
the transmit requests of other message objects are not active (single transmit request).
If this remote frame loses arbitration (to a data frame with identifier=0) or if it is disturbed
by an error frame, it is not retransmitted.
Effects to other CAN nodes in the network
The effect leads to delays of other pending messages in the CAN network due to the high
priority of the Remote Frame. Furthermore the unexpected remote frame can trigger
other data frames depending on the CAN node’s configuration.
Workaround:
1. The behavior can be avoided if a message object is not updated by software when a
transmission of the corresponding message object is pending (TXRQ element is set)
and the CAN module is active (INIT = 0). If a re-transmission of a message (e.g. after
lost arbitration or after the occurrence of an error frame) needs to be cancelled, the
Errata Sheet, C505A-4RM/C505CA-2RM/C505CA-4RM/C505CA-LM/C505CA-4RC
Step ES-CA, CA
3/7
V 1.1, 2006-03
Errata Sheet
Functional Deviations
TXRQ element should be cleared by software as soon as NEWDAT is reset from the
CAN module.
2. The nodes in the CAN system ignore the remote frame with the identifier=0 and no
data frame is triggered by this remote frame.
CAN.3: Description in User's Manual regarding the reception of remote frames and
the data length code (DLC) field is incorrect
It is inaccurately described in the User's Manual on page 6-94 under 'Arbitration
Registers' that 'When the CAN controller stores a remote frame, only the data length
code is stored into the corresponding message object'. The correct should be that the
DLC field remains unchanged in the receiving message object, and that the CPU has the
responsibility to define the DLC of the answering data frame.
This correction will be updated to the future versions of the User's Manuals.
Workaround:
Not applicable.
CAN.4: Flowchart sequence in figure in User's Manual regarding Micro-controller
handling of the Last Message Object is partly incorrect
For the software flowchart figure 6-48 in User's Manual 11.97, the correct would be to
first 'process message contents' and then to 'clear bit NEWDAT'.
process message
NEWDAT: = 0
This correction will be updated to the future versions of the User's Manuals.
Workaround:
Not applicable.
Errata Sheet, C505A-4RM/C505CA-2RM/C505CA-4RM/C505CA-LM/C505CA-4RC
Step ES-CA, CA
4/7
V 1.1, 2006-03
Errata Sheet
Functional Deviations
CAN.5: Description in User's Manual section 6.5.5 regarding the Configuration of
the Bit Timing is partly incorrect (C505CA only)
As described for the CAN Bit Timing Register High BTR1, the minimum total time
requirement for segment 1 and segment 2 is as follows:
tTSeg1 ≥ 3 x tq
tTSeg2 ≥ 2 x tq
The total bit time remains at (tTSeg1 + tTSeg2 ≥ 7 x tq).
This correction will be updated to the future versions of the User's Manuals.
Workaround:
Not applicable.
SWPD.1: Triggering of Software Power Down (SWPD) wake up immediately after
SWPD entry via external interrupt on a frequent basis is not recommended.
When the micro-controller is running at frequencies lower than 10MHz and the external
wake up from SWPD occurs very soon (e.g. <200ms) after entering this mode and this
happens on a regular basis, the internal clock may still be valid when the wake up trigger
occurs. In this rare case, the micro-controller may get confused with its state and
program execution becomes unpredictable.
Workaround:
In applications running at 10MHz or below, that enters and exits the SWPD mode on a
frequent basis, it is recommended to enter Slow Down mode before Power Down mode
entry. On SWPD wake up, the first instruction in the interrupt routine at 07bH should
disable Slow Down mode. This method would only cause an insignificant delay in the
range of s and would ensure specified behavior of the micro-controller. Note that when
Slow Down mode has been entered, there is no longer a minimum time requirement
before SWPD external wake up is triggered.
Errata Sheet, C505A-4RM/C505CA-2RM/C505CA-4RM/C505CA-LM/C505CA-4RC
Step ES-CA, CA
5/7
V 1.1, 2006-03
Errata Sheet
Deviations from Electrical- and Timing Specification
3
Deviations from Electrical- and Timing Specification
DC.4: Minimum limit of logic 0 input current IIL min is lower
The minimum for the logic 0 input current at the ports is lower than the specified values:
IIL min. is –5 µA
(instead of –10 µA)
Errata Sheet, C505A-4RM/C505CA-2RM/C505CA-4RM/C505CA-LM/C505CA-4RC
Step ES-CA, CA
6/7
V 1.1, 2006-03
Errata Sheet
Application Hints
4
Application Hints
No application hints are known for this step.
Hint 1: Content of VR2 register is incremented
The VR2 register has a reset value of 34H.
Workaround:
None.
Errata Sheet, C505A-4RM/C505CA-2RM/C505CA-4RM/C505CA-LM/C505CA-4RC
Step ES-CA, CA