ACG4000CE274

New
Infrastructure type
Old
( HHR-10V10T )
BK-10V10T
■ Typical charge characteristics
16
Voltage (V)
15
14
13
─ ー10 ℃
─
0℃
─ 20 ℃
─ 35 ℃
12
■ Dimensions
Charge : 20 A dT/dt = 0.3 ℃/min +3 A 2 h
11
0
428 (with handles)
1
2
3
4
5
Charge time (hours)
6
7
8
389※
■ Typical discharge characteristics
15
Charge : 20 A dT/dt = 0.3 ℃/min +3 A 2 h
Discharge : 25 ℃
14
159
270
(witn bolt)
Voltage (V)
13
12
11
10
─ 10 A
─ 20 A
─ 30 A
─ 50 A
─ 100 A
247※
9
8
7
151※
※Excluding
0
10
20
30
protrusions
40
50
60
Capacity(Ah)
70
80
90
100
Unit: mm
15
■ Main Specifications
12 V / 90 Ah
Discharge current
100 A
Operating temperature range
-20 ℃ to 60 ℃
Dimensions(mm)
W: 428 × D: 159 × H: 270
Battey cell
BK-10V1S × 10
Volume
18.4 ℓ
Mass
23 kg
Display function
Remaining capacity
13
Voltage (V)
Rated(battery pack)
Charge : 20 A dT/dt = 0.3 ℃/min +3 A 2 h
Discharge : 20 A
14
12
11
─ ー10 ℃
─
0℃
─ 20 ℃
─ 35 ℃
10
9
8
0
10
20
30
40
50
60
Capacity(Ah)
70
80
90
100
*Specifications subject to change.
*Handle, excluding protrusions.
■ Exclusive battery charger
*Under battery charger development
Battery performance and cycle life are strongly affected by how they are used. In order to
maximize battery safety, please consult Panasonic when determining charge/discharge
specs, warning label contents and unit design.
*The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty.
Nickel Metal Hydride Battery
2014/03