Product datasheet OT 6/200…240/24 CE CV Power supplies 24 V Areas of application _ Suitable for indoor and outdoor SELV installations _ Outdoor applications only in suitable installations _ Suitable for use in tight, flat luminaires or installation in suspended ceilings __ Product benefits _ Versatile scope of application due to output power range of up to 240 W _ Very high efficiency and reliability _ Constant luminous flux for very low and high temperatures due to Smart Power Supply June 9, 2016, 10:01:47 OT 6/200…240/24 CE © 2016, OSRAM GmbH. All rights reserved. Page 1 of 4 Product datasheet Technical data Electrical data __ Nominal voltage 200…240 V Mains frequency 50…60 Hz Input voltage AC 180…264 V 1) Total harmonic distortion < 20 % Power factor λ 0.50 ECG efficiency 80 % Device power loss 1.5 W 3) Inrush current 15 A 4) Max. ECG no. on circuit breaker 10 A (B) 30 Max. ECG no. on circuit breaker 16 A (B) 48 Max. ECG no. on circuit breaker 25 A (B) - Surge capability (L-N) 1 kV Nominal output voltage 24 V 5) U-OUT (working voltage) 24 V Nominal output power 6 W 6) Galvanic isolation SELV equivalent Galvanic isolation primary/secondary 3 kV 2) 1) Permitted voltage range 2) Minimum 3) Maximum at 230 V 5) ±0.8 V ,P AC 4) At 240 V =maximum, Ta=25 °C, steady state out AC 6) Partial load 0.4…6 W Dimensions & weight Length 51.0 mm Width 50.0 mm June 9, 2016, 10:01:47 OT 6/200…240/24 CE © 2016, OSRAM GmbH. All rights reserved. Page 2 of 4 Product datasheet Height 22.0 mm Product weight 73.00 g Cable cross-section, input side 1.0 mm² Cable cross-section, output side 1.0 mm² Wire preparation length, input side 10 mm Wire preparation length, output side 10 mm Colors & materials Casing material Plastic Temperatures & operating conditions Ambient temperature range -20…+50 °C Maximum temperature at tc test point 70 °C Max.housing temperature in case of fault 100 °C Permitted rel. humidity during operation 5…85 % Lifespan ECG lifetime 1) At T case __ 50000 h 1) = 60°C at T point / 10% failure rate c Additional product data Encapsulated No Capabilities 1) Dimmable No Overheating protection Automatic reversible Overload protection Automatic reversible Short-circuit protection Automatic reversible No-load proof Yes Max. cable length to lamp/LED module 10 m Suitable for fixtures with prot. class II 1) With OPTOTRONIC dimmers Certificates & standards Approval marks – approval CE / VDE / ENEC 10 Standards Acc. to IEC 61347-2-13/Acc. to IEC 62384/Acc. to EN 55015/Acc. to IEC 61000-3-2/Acc. to IEC 61000-33/Acc. to IEC 61547 Type of protection IP65 June 9, 2016, 10:01:47 OT 6/200…240/24 CE © 2016, OSRAM GmbH. All rights reserved. Page 3 of 4 Product datasheet Logistical data Temperature range at storage -40…85 °C Download Data File Addon Technical Information ADDON TECHNICAL INFO OT 6200-24010 CE VS20 and OT 6200-24024 CE VS20 (GB) Declarations of conformity Declaration of conformity OT 6200-24010 CE CAD data 3-dim 51x52x22 9900045 CAD data 3-dim 51x52x22 9900045 CAD data PDF 51x52x22 9900045 Logistical Data __ Product code Product description Packaging unit (Pieces/Unit) Dimensions (length x width x height) Volume Gross weight 4008321113269 OT 6/200…240/24 CE Shipping carton box 20 328 mm x 76 mm x 138 mm 3.44 dm³ 1212.50 g The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit. Disclaimer Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release. June 9, 2016, 10:01:47 OT 6/200…240/24 CE © 2016, OSRAM GmbH. All rights reserved. Page 4 of 4