Automotive datasheet 8412 EN

customized design!
8412ENHV / 17-175
DC axial fan
– Low noise level by special commutation electronics
– Electronic locked rotor and reverse polarity protection
– Self-diagnosis function: In case of failure (stiffness/blocking) a signal for speed control
will be pulled down to ground. Loss of electrical contact will cause shutdown of motor
– External speed setting via PWM
– Speed control and diagnosis combined in one wire
– Closed loop speed control (restricted, working independently of nominal operating
voltage and charge)
– EMC protective measures suitable for direct connection to vehicle supply system
– Flanges for application in sucking or blowing operation
– Housing made of 2 parts to facilitate assembly and to avoid mechanical stresses
to the bearing system
ebm-papst • St. Georgen
Nominal data
Type
8412ENHV / 17-175
Supply voltage range
V DC
9 … 15
Nominal supply voltage
V DC
12
Nominal current consumption max.
mA
140
Nominal speed max.
min-1
3850
Speed setting (PWM, open collector, f=3…4 kHz)
%
35 … 90
Max. flow rate (p = 0)
CFM
27.90
Max. pressure (V = 0)
Pa
48
Sound pressure level (∆pf)
dB(A)
45
Ambient temperature range
°C
-40 … +70
Service life (at 23°)
h
> 5000
Bearing system
Mass
Ball bearing
g
75
All data are average figures at nominal voltage.
Subject to technical change.
ebm-papst St. Georgen GmbH & Co. KG
Hermann-Papst-Straße 1 • D-78112 St. Georgen • Phone +49 (0) 77 24 / 81-0 • Fax +49 (0) 77 24 / 81-1309 • [email protected] • www.ebmpapst.com/de