HC

C
O
LO & MP
LI
GE
AN
N
T
FR
EE
*R
oH
S
**
HA
331151
82
AY
Applications
n High current type
n Overtemperature and overcurrent protection
Battery cell protection for:
n Notebook PCs
n Tablet PCs
n Smart phones
n Mobile phones
for lithium polymer and prismatic cells
n Controls abnormal, excessive current
instantaneously
n Wide range of temperature options
V
–1
*R
oH
S
C
OM
PL
IA
N
T
HC
5–
Features
Komatsulite™ HC Series Breaker
Ratings
Model
F
RE
E
Specification
HC77AY-1
72 °C ± 5 °C
77 °C ± 5 °C
LE
AD
HC72AY-1
Trip Temperature
Reset Temperature
HC82AY-1
HC85AY-1
HC90AY-1
82 °C ± 5 °C
85 °C ± 5 °C
90 °C ± 5 °C
40 °C min.
DC9V / 25 A, 6000 cycles
Maximum Breaking Current
DC5V / 80 A, 100 cycles
Ro VE LEA
HS RS D
C ION FRE
OM S E
PL AR IA E
NT
*
Contact Rating
Maximum Voltage
DC28V / 25 A, 100 cycles
Minimum Holding Voltage
3 V @ 25 °C for 1 minute
Maximum Leakage Current
200 mA max. @ 25 °C
Resistance
5 milliohms max.
Product Dimensions
Agency Recognition
5.8±0.1
(.228±.004)
2.7±0.1
(.106±.004)
Description
2.7±0.1
(.106±.004)
UL, cUL
0.1±0.01
(.004±.0004)
TUV
2.5±0.1
(.098±.004)
3.75±0.1
(.148±.004)
DIMENSIONS:
MM
(INCHES)
Product Structure
COVER
ARM
CONTACT
ARM
TERMINAL
BASE
HC 72 A Y - 1
Series Designator
Trip Temperature (±5 °C)
• 72
• 85
• 77
• 90
• 82
Arm Material
A = Cu Alloy
COVER
PLATE
PROJECTION
File Number: R50203147
How to Order
1.15
MAX.
(.045)
2.5±0.1
(.098±.004)
File Number: E215638
BIMETALDISC
PTC
BASE
TERMINAL
Manufacturer’s Internal Code
Terminal Type
(with/without Projection & Terminal Length)
PROJECTION
AVAILABLEWITHANDWITHOUTPROJECTIONS.
* RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
**Bourns considers a product to be “halogen free” if (a) the Bromine (Br) content is 900 ppm or less; (b) the Chlorine (Cl) content is 900 ppm or less; and (c) the total Bromine (Br) and Chlorine (Cl) content is 1500 ppm or less.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Komatsulite™ HC Series Breaker
MF-NSMF Series - PTC Resettable Fuses
Typical Performance
Current (A)
Current vs. Temperature Curves
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
HC72AY-1 (Low 67 °C average)
HC77AY-1 (Low 72 °C average)
HC82AY-1 (Low 77 °C average)
HC85AY-1 (Low 80 °C average)
HC90AY-1 (Low 85 °C average)
20
30
40
50
60
70
80
Temperature (°C)
The above curves were derived from placing test samples in an oven at 25 ℃, 40 ℃, 60 ℃ and 70℃, increasing current flow through the
sample at a rate of 0.1 A/minute and recording the current value when the sample trips.
Operation
NORMALCIRCUIT
CURRENT
CIRCUIT
AFTEROPENING
EXCESSIVE
CURRENT
AND/OR
HEAT
VERYLOWCURRENT
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Komatsulite™ HC Series Breaker
MF-NSMF Series - PTC Resettable Fuses
Wiring Recommendations
This is not a surface mount device for reflow soldering. Therefore, Ni tab wiring should be accomplished by either resistance or laser welding.
Solder connections should be avoided.
Typical Part Marking
DIRECTIONMARK
(ALPHANUMERIC
CHARACTER)
12510-I
DATECODE:
MONTH(1~9,X,Y,Z)
DATE
YEAR
MACHINENO.
ROMANNUMERAL(I,II,III,ETC.)=OKAYAMAFACTORY
ARABICNUMERAL(1,2,3,ETC.)=SHIGAFACTORY
**
HC72AY-1
MANUFACTURER’STRADEMARK
TERMINALTYPE
MANUFACTURER’SINTERNALCODE
ARMMATERIAL
(A=CuALLOY)
TRIPTEMPERATURE-°C
(72,77,82,85,90)
SERIESDESIGNATOR
Standard Packaging Specifications
Plastic Bag.......................................................................................................................................................................5,000 pcs. (fixed)
Inner Box..........................................................................................................................................................................5,000 pcs. (fixed)
Outer Box.....................................................................................................................................50,000 pcs. max. (up to 10 inner boxes)
Japan: Tel: +81-6 6319 2281 • Fax: +81-6 6319 2284
Asia-Pacific: Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
EMEA: Tel: +36 88 520 390 • Fax: +36 88 520 211
The Americas: Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com/komatsulite
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Komatsulite™ HC Series Breaker
Caution when using Breaker
Before using the breaker, please fully read the DESIGN AND HANDLING CAUTIONS stated below so that there will be no breaker
performance deterioration and/or damage to the breaker body or terminal.
DESIGN CAUTIONS
1. Use within the electrical ratings specified in this data sheet. If used over the rating of voltage or current, ON-OFF life might be impacted
and contact may be deteriorated due to breaker arm damage.
2. If used over the electrical rating, the circuit may not open safely. Please test your device for any abnormalities and confirm that the breaker
will open the circuit safely in your device.
3. Mount the breaker on your device where heat is the highest in order to transfer it effectively to the breaker.
4. If the breaker is affixed with an adhesive (resin, etc.), fully test, evaluate and verify that the fixative presents no negative effects on the
breaker before proceeding.
5. After the breaker is mounted, affix it so that the breaker body and terminals will not move. If not affixed, breaker resistance could increase
or contact open due to stress during handling or vibration/shock during transportation.
6. Mount the breaker body and terminals in a straight and flat direction. If the body and terminals are mounted in a twisted condition, breaker
resistance could increase or create body damage.
7. If breaker is to be resin-molded, test and evaluate to determine whether the breaker can be used effectively.
8. The breaker cannot be used as a repetitive ON-OFF thermostat.
9. The breaker is not washable. Do not wash.
10. The breaker is not designed nor guaranteed for flow, reflow or hand-soldering applications. If such application is required, test and
evaluate in your specific application to confirm that the breaker can be used.
11. When mounting and after mounting the breaker, do not apply supersonic vibration. Vibration and heat may cause the breaker resistance
to increase or may cause body damage. If you apply supersonic vibration after mounting the breaker, test and evaluate in your specific
application to confirm that the breaker can be used.
12. Do not use the breaker in the following abnormal environments:
a) Water, oil, chemicals or organic solutions
b) Direct sunlight, outdoor exposure, dust
c) Dew condensation, allowing the breaker to get wet
d) Salt breeze, chlorine, hydrogen sulfide, ammonium, sulfide-oxidation, hydrogen chloride, and anywhere there is a possibility of
generating corrosive gas such as ulfurous acid gas
e) Strong static electric charge or electromagnetic wave
13. Thie breaker is not designed or tested for, and should not be used in aerospace, airplane, nuclear, military, life-sustaining medical and
other related equipment.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Komatsulite™ HC Series Breaker
Caution when using Breaker (Continued)
HANDLING CAUTIONS
1. Since the breaker body is composed of plastic parts, do not clamp or dent with tools as this could cause a resistance increase or body
damage.
2. Breaker terminals are thin copper-alloy with right angle edges. Handle carefully to avoid injury to fingers. Handling while wearing finger
cots and tweezers is recommended.
3. When welding breaker terminals or mounting the breaker on a cell or PCM board, be careful to avoid placing excessive stress on the
breaker body and terminals. Excessive stress may cause a resistance increase or body damage. Please refer to the following cautions:
a) Do not apply more than 10 N moment to the breaker body (refer to Figure 1)
b) Do not apply more than 1.5 cN-m twist torque to the breaker body (refer to Figure 2)
c) Do not apply more than 20 N bending force to the breaker body (refer to Figure 3)
d) Do not apply more than 0.6 cN-m twist torque to the breaker terminals (refer to Figure 4)
e) Do not apply more than 2 N force to the breaker terminals (refer to Figure 5)
f) Do not bend terminals more than 45 ° at root (refer to Figure 6)
g) Do not twist terminals more than 20 ° with the breaker body affixed.
4. In breaker body welding, normally there is direct welding (Figure 7) and series welding (Figure 8). In either case, use a suitable jig so that
there will be no stress as stated above.
5. Pull-and-detach strength of the terminal welding should be to your own specification. If the welding result is controlled by resistance,
measurement should be made at close point to the breaker body by “4-point clip method” using a milliohm meter to ensure accuracy
(refer to Figure 9).
6. Avoid putting stress as shown above in 3-a) to 3-g) when the jig is used for welding/additional processing.
Figure 2
Figure 1
Figure 7
Figure 6
Figure 5
Figure 4
Figure 3
45 °
45 °
45 °
45 °
Rod A
Figure 8
Rod A
Rod B
Rod B
Figure 9
Due to possible updates to safety standards and other reasons, there may be changes in
specifications for this data sheet without prior notification. Therefore, before design-in for
your application, please contact us for the most up-to-date specifications.
milliohm meter
REV. 02/16
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.